Download Cabletron Systems 9W006 Specifications

Transcript
Corrected & Known Anomalies
Cabletron SFSmartCell Switch
Part Number
SM-CSI1073
Devices
SmartSwitch 9A656_04
SmartSwitch 9A686_04
Firmware Release
2.04.09
6.0.3
Known Anomalies:
Problem 1: The SFCS device’s Interface Configuration Table view’s
Clocking to Mother Board field is empty, and the same field in the SFCS
Interface Configuration view is red boxed for devices using the 02.02.03
firmware.
Solution: This is a firmware related issue.
Problem 2: AutoDiscovery does not resolve the port connection for the
9A656-04. Although you may see a connection between the switches, you
will need to resolve the port manually.
Solution: To find the port, read the atmInterfaceMyNeighborIpAddress
and atmInterfaceMyNeighborIfName from the ATM MIB. (Not all devices fill
in atmInterfaceMyNeighborIfName with the port number.) The devices
should show atmInterfaceMyNeighborIfName with the port number, and
not the ifDescr value. This attribute is read-write; you can change this
name to another interface name. This way, you can show two ports on one
switch connected to two ports of another switch.
Problem 3: The ANIM Configuration view incorrectly identifies a 3-port
155Mbps SC ANIM as a 2-port 622Mbps SC ANIM.
Solution: This is a firmware related issue.
SPECTRUM Software Release Notice