Download Cisco 15310-MA Troubleshooting guide
Transcript
Chapter 2 Alarm Troubleshooting Alarm Procedures Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447). 2.7.144 LO-LASERTEMP The Equipment Low Laser Optical Transceiver Temperature alarm applies to the TXP and MXP cards. For more information about this alarm, refer to the “Alarm Troubleshooting” chapter of the Cisco ONS 15454 DWDM Troubleshooting Guide. 2.7.145 LOM Default Severity: Critical (CR), Service-Affecting (SA) for STSMON and STSTRM; Major (MJ) for VT-TERM SONET Logical Objects: STSMON, STSTRM, VT-TERM The Optical Transport Unit (OTU) Loss of Multiframe is a VCAT member alarm. (VCAT member circuits are independent circuits that are concatenated from different time slots into a higher-rate signal.) The alarm applies to OCN ports when the Multi Frame Alignment Signal (MFAS) overhead field is errored for more than five frames and persists for more than 3 milliseconds. Note Optical cards do not recognize the LOM. The system redirects the LOM alarm to the incoming side so that any optical card can display this alarm as a TERM alarm. Clear the LOM Alarm To clear the alarm, log into the Technical Support Website at http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA) problem. 2.7.146 LOP-P Default Severity: Critical (CR), Service-Affecting (SA) SONET Logical Objects: STSMON, STSTRM A Loss of Pointer Path alarm indicates that the SONET path pointer in the overhead has been lost. LOP occurs when valid H1/H2 pointer bytes are missing from the overhead. Receiving equipment monitors the H1/H2 pointer bytes to locate the SONET payload. An LOP-P alarm occurs when eight, nine, or ten consecutive frames do not have valid pointer values. The alarm clears when three consecutive valid pointers are received. The LOP-P alarm can occur when the received payload does not match the provisioned payload. The alarm is caused by a circuit type mismatch on the concatenation facility. For example, if an STS-1 is sent across a circuit provisioned for STS-3c, an LOP-P alarm occurs. Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0 2-98 78-18394-01
Related documents
Cisco Systems ONS 15310-CL Troubleshooting
Cisco ONS 15600 Troubleshooting Guide, Release 6.0
Cisco ONS 15454 SDH Specifications
Cisco 15454-TCC - Network Processor Card Specifications
Cisco ONS 15200 Web Interface Software User Manual
Release Notes for Cisco ONS 15200 SNM Software Release 1.1(2)
Cisco Systems 15327 User's Manual
Converters.TV 15200 Specifications
Cisco 20-m Single-Ended Cable for HDE1 FMEC
Cisco 1port STM-16 SH (any slot) 1310nm