Download Agilent Technologies E6640A EXM Technical data
Transcript
GSM/EDGE Programming Commands GSM Loopback BER GSM Loopback BER This section provides the remote control SCPI commands for the GSM Loopback BER measurement from within the List Sequencer. This measurement is available only if you have the GSM/EDGE measurement application licensed on the test set. GSM/EDGE Programming Commands The GSM Loopback BER measurement is based on the GMSK Phase and Frequency (PFER) measurement, and uses remote commands associated with that measurement. For more detailed information about the GMSK Phase and Frequency measurement, refer to the online help associated with the GSM/EDGE measurement application, which is also available in PDF format (“User’s and Programmer’s Reference”) on the Agilent website, www.agilent.com/find/e6640a. Loopback BER measurement SCPI commands The following commands are used to set up the Loopback BER measurement from within the sequence analyzer mode. [:SENSe]:LSEQuencer:EDGE:PFERror:BSYNc:SOURce NOTE “EDGE” (and not “GSM”) is used to designate the GSM/EDGE mode in commands Loopback BER results Index Result Parameter 0 Loopback bit error ratio. 1 Total tested bit number. 2 Failed bit number. 3 Reserve. 186 Chapter 13