Download enphase Envoy Technical data
Transcript
Envoy Installation and Operation Message Shown on Events and Inventory Screens Microinverter grid configuration failure cleared after xx attempts Description Description: A failed attempt to change the grid profile for the microinverters has cleared. The grid profile was successfully applied. xx = number of attempts Recommended Action: No action is required. Module Sleeping Description: The microinverter is off for the night. Recommended Action: No action is required. No Grid Profile Recommended Action: Ask the installer to use the Envoy Gateway interface to select a grid profile for this system. For more information, see “Change or View the Grid Profile” on page 41 Description: The Envoy has not been set up with a grid profile for the microinverters. Over Temperature Description: The microinverter is too hot and is not producing power. This very rare condition usually clears without intervention. Recommended Action: No action is required unless the condition persists. If it persists, contact Enphase Energy customer support. Power generation off by command Description: The microinverter is not producing power by user command. This uncommon condition will occur only during isolated troubleshooting procedures by Enphase personnel. Recommended Action: No action is required. Power On Reset Description: The microinverter has powered on after having both AC and DC disconnected. Recommended Action: No action is required. RGM Error Description: The Enphase-compatible Revenue Grade Meter (RGM) has failed. Recommended Action: Contact your installer to arrange for installation of a replacement meter. RGM Power Quality Warning Description: The Enphase-compatible Revenue Grade Meter (RGM) reports that the AC voltage coming from the utility is either too low or too high as specified by applicable regional standards. This is usually a temporary condition that will clear when power quality from the local utility returns to normal. Recommended Action: No action is required unless the condition persists. If the condition persists, contact your installer. Shutdown Description: The Envoy has been powered down (unplugged from AC power). Recommended Action: Restore AC power to the Envoy. Startup Description: The Envoy has been powered back up (plugged back in to AC power). Recommended Action: No action is required. Transient Grid Profile Recommended Action: No action is required. This condition will clear once the grid profile test is complete. Description: This system is currently in test mode. 59 2014 Enphase Energy Inc. 141-00011 Rev 05