Download Sharp AL-1043 Service manual

Transcript
Main
code
66
Sub
code
11
Contents
300bps signal send (Max.
value)
Details of function/operation
[Function]
Use to set the 300bps signal send (Max. value).
1:
2:
3:
4:
5:
6:
NO SIGNAL
11111
11110
00000
010101
00001
[Operation]
1) Initial display
SELECT SIGNAL
PRESS ←, →
2) [←/→] or after 2sec
Every time when [→] key is pressed, the second line is changed in the sequence of No. 1 → 2 →
3 → 4 → 5 → 6 → 1.
When [←] key is pressed, the sequence is reversed.
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
∗ [CLEAR] key: FAX control is terminated.
3) [ENTER] key
OUTPUTING SIGNAL MAX
PRESS CLEAR TO STOP
∗ [CLEAR] key: Returns to "1) Initial display".
12
300bps signal send (Soft
SW set value)
[Function]
Use to set the 300bps signal send (Soft SW set value).
1:
2:
3:
4:
5:
6:
NO SIGNAL
11111
11110
00000
010101
00001
[Operation]
1) Initial display
SELECT SIGNAL
PRESS ←, →
2) [←/→] or after 2sec
Every time when [→] key is pressed, the second line is changed in the sequence of No. 1 → 2 →
3 → 4 → 5 → 6 → 1.
When [←] key is pressed, the sequence is reversed.
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
∗ [CLEAR] key: FAX control is terminated.
3) [ENTER] key
OUTPUTING SIGNAL SSW
PRESS CLEAR TO STOP
∗ [CLEAR] key: Returns to "1) Initial display".
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 33