Download RAD Data comm ASMi-31 Specifications

Transcript
Installation and Operation Manual
Chapter 3 Operation
Table 3-2. ASMi-31 Indicator Status
3.3
Indicator
Status
PWR
On
LCD Display
Displays opening screen:
“ASMi-31 REV x.x
I N I T I A L I Z I N G...”
SYNC
Red
TST
Off
TD
Depends on DTE data transmission.
RD
Off
RTS
Depends on DTE RTS signal status.
DCD
Off
ASMi-31 Default Settings
Table 3-3 and Table 3-4 list default values of the line and DTE parameters.
Table 3-3. Line Parameters
Parameter
Default Value
CLKTYPE
INT RCV
ADAPT
RAD PROP
Table 3-4. DTE Parameters
Note
ASMi-31 Ver. 3.0
Parameter
Default Value
LLB
ENABLE*
RLB
ENABLE*
MODE
SYNC
DATARATE
64K
CNT SIG-DCD
SW
CNT SIG-DSR
SW
For ASMi-31 with X.21, G.703 Codirectional and Ethernet DTE interfaces, the LLB
and RLB default values are always set to DISABLE because these interfaces do not
support loopback activation via DTE connector pins.
ASMi-31 Default Settings
3-3