Download MTD 21A-410-022 Operating instructions
Transcript
ARMY TM 9-6115-464-12 AIR FORCE TO 35C2-3-445-1 NAVY NAVFAC P-8-624-12 Table 4-1. Unit Preventive Maintenance Checks and Services - Continued Location Item No. 11 Interval Weekly Item to Check\ Service Main Fuel Tank Procedure Not Mission Capable If: Drain water and sediment. NOTE In freezing weather, drain shortly after operation. Allow to drain until fuel runs dear. 12 Weekly Fuel Pump Strainers Service (para 4-29, Figure 4-16). NOTE In freezing weather, drain shortly after operation. Allow to drain until fuel runs dear. 13 Monthly Generator Set Check entire unit for missing, loose, or damaged parts and hardware, and for unusual wear or deterioration. 14 Monthly Batteries Check electrolyte level. Check condition with a hydrometer. Add water as required (para 3-4). 15 Monthly V-Belt Inspect for worn, frayed, cracked, or oil-soaked belt. Check adjustment. If adjustment is required, adjust for a 1/2 inch deflection when belt is depressed at a point midway between alternator and water pump pulley (para 4-40). 4-7