5–75 SECONDS=nn As soon as the POWEROFF command is entered, all disk units in the cabinet are set to write-through. When the time interval, as represented by nn seconds, has elapsed, an orderly rundown of all units is started. When all units in the cabinet are successfully rundown, cabinet power is turned off. Table 5–4 shows what action will be taken depending on the switch settings and the results of the attempted flush: CAUTION: If the BATTERY_OFF switch is used with the OVERRIDE_BAD_FLUSH switch, unwritten data could be lost. Do not power off the subsystem until the unwritten data has been recovered. Table 5–4 Poweroff Switch Settings Battery Switch Override Switch Flush Results Action BATTERY_ON OVERRIDE_BAD_FLUSH Success Controller and units in the cabinet are shutdown and the ECB is powering the cache module. BATTERY_ON OVERRIDE_BAD_FLUSH Failure Controller and units in the cabinet are shutdown and the ECB is powering the cache module. BATTERY_ON NO_OVERRIDE_BAD_FLUSH Success Controller and units in the cabinet are shutdown and the ECB is powering the cache module. BATTERY_ON NO_OVERRIDE_BAD_FLUSH Failure Nothing is shutdown, the ECB is powering the cache module, and the user is notified of a bad flush. Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Related documents
Compaq HSG80 - StorageWorks RAID Array Controller Specifications
Storage Map Template for PVA 2
HSZ70 Array Controller HSOF V7.3 CLI Reference Manual
Digital Equipment Corporation HSZ50 Technical data
Compaq HSZ80 Technical data
HP 9000 rp7440 Specifications
Digital Equipment Corporation Storage Works User`s guide
Cambex AIX Specifications
Compaq 4354R - StorageWorks Enclosure Storage Technical data
HP StorageWorks HSG60 and HSG80 Array Controller