Download Compaq HSZ80 Technical data
Transcript
5–145 UNMIRROR Converts a one-member mirrorset back to a non-mirrored disk drive and deletes its mirrorset from the list of known mirrorsets. This command can be used only on mirrorsets already members of higher-level containers (stripesets or units). The UNMIRROR command is not valid for disk drives having a capacity greater than the capacity of the existing mirrorset. If a mirrorset is comprised of disk drives with different capacities, the mirrorset capacity is limited to the size of the smallest member; larger members contain unused capacity. If a member with unused capacity is the last remaining member of a mirrorset, the UNMIRROR command cannot be used to change the disk drive back to a single-disk unit. This change would cause a change in the reported disk capacity, possibly corrupting user data. Syntax UNMIRROR disk-name Parameter disk-name Specifies the name of the normal mirrorset member to be removed from a mirror storageset. Example This example shows how to convert DISK10300 back to a single device: UNMIRROR DISK10300 Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Related documents
Compaq HSG80 - StorageWorks RAID Array Controller Specifications
Storage Map Template for PVA 2
HSZ70 Array Controller HSOF V7.3 CLI Reference Manual
Digital Equipment Corporation HSZ50 Technical data
Compaq HSZ80 Technical data
HP 9000 rp7440 Specifications
Digital Equipment Corporation Storage Works User`s guide
Cambex AIX Specifications
Compaq 4354R - StorageWorks Enclosure Storage Technical data
HP StorageWorks HSG60 and HSG80 Array Controller