Download ALLEN & HEATH ML4000 User guide
Transcript
CONNECTING THE POWER UNIT Connect only the Allen & Heath power unit specified for the console. The standard unit for GL4000 is the RPS11. This is an external 3U 19" rack mounted unit that connects to the console via the separate DC cable supplied. The RPS11 is a low noise linear design that converts AC mains voltage to the DC voltages required to power the console. It also provides +48V phantom power for use with high quality powered microphones. The presence of AC mains voltage is shown on the power unit front panel neon indicator. The presence of the DC voltages is shown on the console power indicator LEDs. A second backup RPS11 may be connected to the console through the optional RPSD-2 dual supply combiner unit available from your Allen & Heath agent if required. DO NOT OBSTRUCT VENTILATION OPENINGS. ALLOW ADEQUATE VENTILATION AROUND THE UNIT. SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY. DC FUSES CAUTION: FO R CONTINUED PROTECTION AGAIN ST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING . ATTE NTIO N: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTE RISTIQUES. T 10A 250V 20mm ON OFF V+ V- SAFETY WARNINGS ! DO NOT OBSTRUCT VENTILATION OPENINGS. ALLOW ADEQUATE VENTILATION AROUND THE UNIT. WARNING - THIS APPARATUS MUST BE EARTHED. WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE CAUTION AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. NO USER SERVICEABLE PARTS INSIDE Ensure that the warnings printed on the power unit (shown here) are followed. Always switch the power unit off before connecting or disconnecting the console power cable. It is normal for the power unit to dissipate heat. Do not cover the unit or position it on soft furnishings during operation. Do not position other equipment known to generate significant amounts of heat below the unit. It is recommended that rack units containing high power amplifiers and other heat dissipating equipment are fitted with cooling fans. BEFORE SWITCHING ON ! Check that the voltage indicated on the fuseholder is correct for the mains voltage in your area. Check that the mains IEC connector is fully inserted into the inlet socket. S ER IA L No: AC MAINS IN ~ 47-63Hz 320VA MAX 300W MAX 14 FUSE TYPE T 3.15A 20mm T 5.0A 20mm AC SUPPLY 220 - 240V~ 100 - 120V~ Check that the DC power cable is correctly fitted to both the power unit and the console. The locking ring should be screwed in place. It is recommended that audio power amplifiers are switched on last and switched off first to prevent possible damage to loudspeakers. Check the system for safety earthing.