Download Case Communications 3200 Specifications
Transcript
The miscellaneous LED for each line will illuminate for the following reasons: 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) PCM Loss AIS Frame Sync Loss Error Rate 10-3 Frame Slip Multiframe Sync Loss TS16 A.I.S Low Error Rate Line Output Fail Local Loop Incoming Loop Both miscellaneous LEDs will illuminate for the following reasons. 1) 2) 3) 4) 5) 6) System Restart Un-configured Config Rx Fail (Transfer of data from the System Controller) Config Tx Fail (Transfer of data to the System Controller) Self Test Fail Card in Bypass 3.2 Dual LIU Adaptors DT315 and DT316 I/O adaptors must be used in conjunction with the Dual LIU. These include the isolation/matching transformers and bypass relays. The I/O adaptors provide the means of connection to the PCM lines and G.703 clock (See Section 2.2.5). Knurled screws are supplied with the I/O adaptors to fit them to the chassis, these must be used to ensure adequate earthing of the connector screens. 3.2.1 DT315 75 ohm I/O Adaptor This adaptor uses standard 75 ohm BNC sockets for connection to the two PCM lines and the G.703 clock. As supplied, the screens of the output sockets are connected to earth and the screens of the input connectors are isolated from earth. (See Section 2.2.5) X723-300151 3-5 Issue 2