Série 32 Mlift Vector - Prog.Vectorielle
Installation manual
Chapter VII - page 70
PARAMETER DEFINITIONS
Segment 3: OUAVAP2N0 (Open Before Stop of Door 2 at
Level 0).
We program segment 3 to " 1 " when we want to carry out an opening before stop of door
2 at level 0.
We program segment 3 to " 0 " in the reverse case.
Segment 2: STPOU0 (Parking Door 2 Open at Level 0).
We program segment 2 to " 1 " when we want to park the car with door 2 open at level 0.
We program segment 2 to " 0 " in the reverse case.
Segment 1: SER2IN0 (Service 2 Not Allowed at Level 0).
We program segment 1 to " 1 " when the opening of door 2 at level 0 is not allowed.
We program segment 1 to " 0 " when we allow the opening of door 2 at level 0.
Segment 0: OUNSIM0 (Non Simultaneous Opening at Level 0).
We program segment 0 to " 1 " when the simultaneous opening of doors 1 and 2 at level 0
is not allowed (locking effect).
We program segment 0 to " 0 " when we allow the simultaneous opening of doors 1 and 2
at level 0.
This function can only be used in the double service selective.
• Par Address 69: best displayed in segment mode.
At this address, we define the functioning of door 2 for level 1.
•
Par Address 6a:
..... same for level 02.
•
Par Address 6b:
..... same for level 03.
•
Par Address 6c:
..... same for level 04.
•
Par Address 6d:
..... same for level 05.
•
Par Address 6e:
..... same for level 06.
•
Par Address 6f:
..... same for level 07.
•
Par Address 70:
..... same for level 08.
•
Par Address 71:
..... same for level 09.
•
Par Address 72:
..... same for level 10.
•
Par Address 73:
..... same for level 11.
•
Par Address 74:
..... same for level 12.
•
Par Address 75:
..... same for level 13.
•
Par Address 76:
..... same for level 14.
•
Par Address 77:
..... same for level 15.