Download User guide for thermometer TM747DU
Transcript
Table of Contents TM-7XX series thermometer K/J/T/E/R/S/N Types Users Manual YC-747UD PC Introduction 1 Features 2 General specifications 3 Electrical specifications 4 Names of parts 5 Operation 6 Battery replacement 16 Caution 17 Introduction Features Thank you for purchasing the temperature gauge from us. Please take a few minutes to browse through this user manual before you begin to operate the unit to ensure that you are fully familiarized with how best to operate the temperature as accurately and safely as possible. The TM-7XX serial temperature gauges features a microprocessor-ratsd digital temperature gauge, which according to varied input configurations and different thermocouple types, is divided into 48 modes, refer to the table below for a concise summary of subtle distinctions in their designed functions. 1 1.The maximum displays for four temp. values. 2. Resolution 0.1℃/0.1℉ ,1℃/1℉. 3.Swift response. 4.Setting alert temperature range. 5.With auto power off function. 6.With low battery indicator function. 7.With a perpetual calendar function. 8.With "COUNT"function. 9.With T1~T4 exchange to main display function. (for above dual channel modes) 10.With T1-T2 function.(for dual channel modes), T3-T4 function(for four channel). 11.Additional features include: HOLD, ℃ / ℉ /K, REL,CHAN,MAX/MIN/AVG,1 ,TYPE,TIME (CLOCK setting), LIMIT(Hi/Lo setting). 12.CE certified, according to ITS-90 law. 2 General Specifications 1.Display Mode: Four-digit liquid crystal display. 2.Polarity indicator: No indicator is shown when readouts are in the positive value, while the symbol"-" is prompted when readouts fall into the negative value. 3.Overload indicator: The "OL"or"-OL"indicator. 4.Low-battery indicator: The symbol" B "is prompted on the LCD when the battery runs low. 5.Power source: Four DC-1.5V/UM-4 batteries. 6.Auto power off: The unit no operations are over 20-minute,the battery power will be turned off. Press the "Shift" key for 3 seconds, the auto power off will be cancelled. 7.Sample rate:1time/sec. 8.Battery life: Approx. 550 hours. 9.Operating Temperature and Humidity: 0℃ ~50℃(32℉~122℉),0~80%RH. 10.Storage Temperature and Humidity: -20℃~60℃ (-4℉~140℉),0~80%RH. 11.Dimension:164x76x32mm(LxWxH). 12.Weight: Approx. 415g(include batteries). 13.Accessories: (A) DC-1.5V/UM-4(4pcs). (B) Housing(1pcs). (C) K-type thermocouple wire. (single channel x1pcs, for above dual channel x2pcs). (D) Users manual(1pcs). 3 Electrical Specifications 1.Temp.unit: Celsius temp.(℃ ). Fahrenheit temp. (℉).Absolute temp.( K ). 2.Measurement Range:( At 23 5℃ , 80%RH) K-type:-100℃~1300℃(-148℉~2372℉) J-type:-100℃~1000℃(-148℉~1832℉) T-type:-100℃~400℃(-148℉~752℉) E-type:-50℃~800℃(-58℉~1472℉) R&S-type:0℃~1700℃(32℉~ 3092℉) N-type:-100℃~1300℃(-148℉~2372℉) 3. Accuracy: The basic accuracy does not include the error of the thermocouple. K/J/T/E/-type: (0.1% reading+0.7℃)-100℃~-1300℃ (0.1% reading+1.4℉)-148℉~2372℉ R/S-type: (0.1% reading+2℃) 0℃~1700℃ (0.1% reading+4℉) 32℉~3092℉ N-type: (0.1% reading+1.5℃)-100℃~1300℃ (0.1% reading+3℉ )-148℉~2372℉ 4.Resolution: 0.1℃ 1℃ -100℃~1300℃ -100℃~200℃ K -100℃~150℃ -100℃~1000℃ J -100℃~150℃ -100℃~400℃ T -50℃~100℃ -50℃~800℃ E 0℃~1700℃ R 0℃~1700℃ S ℃~1300℃ -100 -100℃~150℃ N 4 Operation Names Of Parts 1. 3 2. C / F/K: The temperature Unit selection key. Press the key to sequentially alternate the three temp. unit of ℃ , ℉ and K. YC -7 47 UD 5 1 :Power ON/OFF key. Press the power button to turn the power ON or OFF. 4 PC 7 2 6 1.LCD display 2.Function control key 3.Thermocouple input jack 3.HOLD:The readout hold function key. Press the "HOLD"key, a "HOLD" icon will display on the LCD and the readout held in; press the "HOLD" key once more to cancel the "HOLD" function. 4.MAX/MIN/AVG:The maximum/minimum/ average readout function key T1 TYPE:K 4.Battery cover 25 5.PC input jack 6.Shift button 7.Power button 5 MAX AVG MIN T1 TYPE:K ℃ step1 press Step4 press AVG 25 MAX T1 TYPE:K 25 MAX AVG MIN ℃ MAX AVG MIN Step3 press MAX AVG MIN 6 T1 TYPE:K ℃ Step2 press MIN 25 ℃ Operation Operation 5.REL:The minus relative readout function key. Press the "REL" key, a "REL" icon will display on the LCD and the original of a temp. will become to 0, and save the original temp. to make a standard value. Whenever the input temp. shifts, the LCD will shows the minus value of original temp. value and input temp. Value. T1 TYPE:K 25 ℃ 7.CHAN:every input temp. value changed to main display function key.(for above dual channel modes) A.dual channel T1 TYPE:K T2 30 25 ℃ step1 press T2 TYPE:K CHAN 25 T1 30 step2 press ℃ CHAN T1 become main display step1 press T1 TYPE:K REL REL 25 ℃ 0.0 original temp. Save25 B.triple channel T1 TYPE:K T2 step2 press T1 TYPE:K REL REL 30 ℃ 5.0 30 T3 50 25 ℃ CHAN step3 press 25 T3 TYPE:K CHAN T2 30 T3 30 T1 step2 press 30 ℃ CHAN 25 50 ℃ C.four channel T1 TYPE:K T2 30 T3 50 25 T4 ℃ step1 press T2 TYPE:K CHAN 40 step4 press T1 T4 TYPE:K CHAN T2 7 T2 TYPE:K T1 input temp. 30-25=5 6.1 :1 or 0.1 unit selection function key. Press the "1 "key, the whole resolution will become 1℃ / 1 ℉,and no dot. Press the key once more, the display will restore common state(the resolution will become 0.1℃/ 0.1℉). P.S:The resolution of the thermocouple types is shown in page 4. step1 press 30 T3 25 50 40 T1 ℃ 25 8 T3 30 T4 step2 press 50 ℃ CHAN 40 step3 press T3 TYPE:K CHAN T2 30 T1 25 50 T4 ℃ 40 Operation Operation 8.TYPE:select thermocouple type function key. TM-7XX series according to different modes, there are seven types in all. Other modes can selected by users besides TM71XX,TM-72XX,YC-73XX, TM-74XX. The method of operation as follows: 9.COUNT: The count time setting function key. The max count time is 99 hours and 59 minutes. T1 TYPE:K T2 T1 TYPE:K T2 30 T3 50 25 T4 ℃ press 30 T3 50 ℃ 2540 T4 step1 press up key T1 TYPE:K T2 T3 50 25 ℃ over 1 hour 30 00:00m:s TYPE:KJ TERSN T1 TYPE:K 40 left key T3 50 25 ℃ Press up key back to main display. T230 1:00 h:m A.Use , key to choose"type". B.The word will flicker for the chosen"type". C.To confirm it,then press "SHIFT"key. 10.TIME:To see the present time function key. T3 T3 step1 T1 50 50 press TYPE:K ℃ T1 TYPE:J The type became to "J" type. T2 30 T3 50 25 T4 ℃ T2 30 2540 T4 right key T2 30 T4 ℃ 40 step2 press down key 40 Press right key back to main display. 9 12:00 10 12:00 y 0101 2001 Operation Operation 11.T1-T2: for above dual channel modes. step1 press T1 TYPE:K T2 30 T3 50 ℃ 2540 T4 T1 TYPE:K SHIFT CHAN T2 step4 press 30 T1 TYPE:K SHIFT SHIFT SHIFT T3 T2 T1-T2 ℃ 2540 step1 press step2 press CHAN T1 TYPE:K T4 step3 press 50 25 30 50 T3 13.LIMIT:To enforce alarm function key. ℃ T1 TYPE:K SHIFT T2 -5 30 T2 30 T3 50 ℃ 2540 T4 T1 TYPE:K SHIFT SHIFT T2 SHIFT 50 T3 25 T1-T2 ℃ -5 T1 TYPE:K SHIFT 1 step4 press T2 30 30 T3 50 ℃ 2540 SHIFT T4 step2 press ℃ 2540 step3 press LIMIT T3 50 1 T4 T1 TYPE:K T2 30 LIMIT T3 50 25 T4 ℃ 40 12.T3-T4: for four channel modes. step1 press T1 TYPE:K T2 30 T3 50 ℃ 2540 T4 T1 TYPE:K SHIFT HOLD step4 press T3-T4 10 T1 TYPE:K SHIFT SHIFT SHIFT T3 T2 30 T3 ℃ 2540 SHIFT ℃ 11 HOLD T4 T1 TYPE:K T3-T4 10 T4 step2 press 2540 step3 press 50 50 T3 50 25 T4 ℃ 40 P.S1:When the main display temp.value is higher than the alarm setting Hi temp.value or lower than the alarm Lo setting temp.value, the alarm will continue send out. 2:The Hi/Lo setting temp. Value of the thermocouple types are different. Type Hi/Lo Lo Hi -99.9 K 1300 1000 -99.9 J -99.9 T 400 E -50 800 R 1700 0 0 1700 S N 1300 -99.9 12 Operation 14.Hi/Lo:The alarm Hi/Lo temp.value setting. step1 press T1 TYPE:K T2 30 T3 50 ℃ 2540 T4 SHIFT SHIFT T1 TYPE:K SHIFT T2 30 T3 50 step2 press ℃ 2540 MAX MIN AVG 15.CLOCK:To enforce date setting function key. step1 press T3 T3 T1 T1 50 50 step2 press SHIFT TYPE:K TYPE:K ℃ T2 30 2540 T4 SHIFT T2 SHIFT 30 ℃ 2540 K ℃ F T4 T4 A.Use , key to move place. B.Use , key to set Hi temp. value. C.The flicker word is the adjustable word. LIMIT Hi 1300 step3 press SHIFT A.Use , key to move place. B.Use , key to set Lo temp. value. C.The flicker word is the adjustable word. LIMIT Lo -99.9 step4 press SHIFT Back to main display. Operation A.Use , key to move place. B.Use , key to set hour & minute. C.The flicker word is the adjustable 3003 2004y word. step3 press SHIFT 12:01 A.Use , key to move place. B.Use , key to set date & month. y C.The flicker word is the adjustable 3003 2004 word. step4 press SHIFT 12:01 A.Use , key to move place. B.Use , key to set year. C.The flicker word is the adjustable y word. 3003 2004 12:01 step5 press SHIFT Back to main display. 13 14 Battery replacement Operation 16.perpetual calendar: step1 power on T1 TYPE:K T2 30 T3 50 Step2 ℃ 2540 T4 + 1.Press right key and hold on. 2.Press power key. 3.Set free two keys. 12:50 y 0503 2004 17. :backlight.(for option) A.Press the backlight button to turn the backlight ON or OFF. B.In no turn off backlight condition, the backlight function can keep on 1 minute. 15 1.The symbol " B " that appears in the upper left of the LCD display indicates that the unit's battery is running low. Please replace the 1.5V battery at once to ensure the test accuracy. 2.Remove the battery cover by one screwdriver. 3.Replace the old battery with four new 1.5V batteries and lock the battery cover. 4.Prior to replacing the battery, please make certain to remove the thermocouple from the temperature gauge as a safety precaution. 5.When in extended idle, please remove the 1.5V battery from the temperature gauge and store the temperature gauge only in a cool and lowhumidity setting. 6.To avoid combustion, DO NOT dispose of batteries in general into an open flame. 7.Caution the positive and negative polarity when loading battery. 8.Please abide by pertinent laws and regulations when disposing of used batteries. 16 Caution 1.Input protection: The temperature jack carried a maximum voltage of 24 volts DC or AC . 2.Temperature jacks: Design for the insertion of a standard small thermocouple jacks, which has a center spacing of 7.9mm between the two prongs. 3.Please DO NOT placed inside a microwave for temperature testing. 4.A correct thermocouple slot should be chosen when operating the temperature gauge. 5.Please DO NOT attempt to use a temperature gauge that is not working properly, for this may result in physical harms, send for repair service at once. 6.Please DO NOT attempt to operate the temperature gauge in the around sites where explosive gases, vapor or dust particles are present. 7.Please refrain from subject the paired thermocouple or the grounding between the thermocouples to a voltage exceeding what has been marked on the unit. 8.When gauge occur crashed , please take one battery out for above one minute. Then place the battery back and restart the gauge. 17 TM-7XX series thermometer K/J/T/E/R/S/N Types Data Logger Users Manual C YC-747UD PC Operation Operation 1.PC:Turn on"PC"function,the meter &PC application program communication. When turn on "PC" function ,The auto power off will be canceled, and the power off will be canceled, too. step1 press A T1 TYPE:K 25 ℃ T1 PC TYPE:K 25 PC step2 press ℃ PC ℃ T2 back to main display 2.REC: Turn on REC function,the reading value of meter, according to transmitting the settlement of interval time,will write down in the memory real time.Can write down 10000 records at most. When turn on "REC" function,the auto power off will be canceled, and the power off will be canceled,too.When the memory is filled, the display will appeared"ou" word.For Data Logger models. A T1 TYPE:K 25 ℃ step1 press REC T1 REC TYPE:K 25 ℃ T1 REC TYPE:K 30 2540 T4 date REC ℃ time 2205 22:05 h:m A.Use , key to choose "channel". B.Use , key to choose "number".Hold or key above 1 second, the readout rate will be added. About 50 numbers/sec. step2 press T1 CALL TYPE:K SHIFT SHIFT 1000 25 ℃ step3 press 2205 22:05 h:m CALL BYTE 1293 2205 2004 y surplus space ℃ step5 back to step1 press date back to main display 25 CALL OU 25 Memory is filled 1 3.CALL:Can inquire that the data of every channel, can also inquire about the surplus space of the memory. For Data Logger models. Each time entering to inquire data by the last. When turn on "CALL" function, the auto power off will be canceled. last number step1 T1 A T3 T1 CALL 1000 50 press TYPE:K TYPE:K BYTE step4 press 1293 SHIFT SHIFT CALL 2205 step2 press 2 2004 y year 6. SHIFT + Operation 4. SHIFT + CALL :remove the record of the memory. For Data Logger models. step1 press A T1 TYPE:K T2 30 T3 50 SHIFT ℃ 2540 SHIFT T4 A T1 TYPE:K SHIFT T2 30 T3 50 ℃ 2540 step2 press back to main display A T1 TYPE:K flickerin g finish remove CLEA CALL T2 CALL CLEA express it in movements by flickering SHIFT back to main display 30 PC :Carry out the PC interval setting. The biggest settlement time is 59 minutes and 59 seconds .Minimum to set for time is one second. Enter and show 00:01 seconds of initial value for the first time. Enter and show settlement value last time for the second time after. For USB or Data Logger models. 3 T3 50 REC INTV ℃ 2540 T4 00:02 m:s step1 SHIFT SHIFT press A T1 TYPE:K SHIFT T2 5. SHIFT + :carry out the record interval setting. The biggest settlement time is 59 minutes and 59 seconds. Minimum to set for time is one second. Enter and show 00:01 seconds of initial value for the first time. Enter and show settlement value last time after.For Data Logger models. CALL T4 Step3 press REC 30 T3 50 ℃ 2540 step2 press REC INTV SHIFT REC T4 00:01 m:s REC INTV 00: 0 1 m:s The flashing number represents adjustable number. 4 Operation 7. + SHIFT PC : back to main display A T1 TYPE:K T2 30 T3 50 ℃ PC INTV 2540 T4 00:02 m:s step1 SHIFT SHIFT press A T1 TYPE:K SHIFT T2 30 T3 50 ℃ 2540 step2 press PC INTV SHIFT PC T4 00:01 m:s PC INTV 00: 0 1 m:s The flashing number represents adjustable number. 5