Download Ethernet POWERLINK Controlled Node

Transcript
Overview
117/297
Threshold_U32
This item represents the threshold value of the counter for collision events. When the threshold is
reached,
 a specific action might be executed
 and the counter for collision events should be reset to 0
according to the Ethernet Powerlink specification. Setting the value to 0 disables the entire threshold
counting mechanism for this kind of event.
Sub Index
3
Name
Threshold_U32
Description
Threshold for collision events
Data type
UNSIGNED32
Entry Category
Optional
Access
Read/write
PDO mapping
No
Value
0-232-1
Default value: 15
Table 101: Object 0x1C0A DLL_CNCollision_REC – Threshold_U32