Download Ethernet POWERLINK Controlled Node
Transcript
Overview 117/297 Threshold_U32 This item represents the threshold value of the counter for collision events. When the threshold is reached, a specific action might be executed and the counter for collision events should be reset to 0 according to the Ethernet Powerlink specification. Setting the value to 0 disables the entire threshold counting mechanism for this kind of event. Sub Index 3 Name Threshold_U32 Description Threshold for collision events Data type UNSIGNED32 Entry Category Optional Access Read/write PDO mapping No Value 0-232-1 Default value: 15 Table 101: Object 0x1C0A DLL_CNCollision_REC – Threshold_U32 Ethernet POWERLINK Controlled Node | DOC071104API12EN | Revision 12 | English | 2013-10 | Released | Public © Hilscher, 2006-2013