Download Kenmore Elite 30'' Professional Style Range Hood Shell 51303 Installation Guide

Transcript
L
!
T
E
,,®
Range Hood
Use & Care / Installation Manual
Campana
de cocina
Manual de uso y cuidado / instalaci6n
Models
Modelos
233.51303200
(30" wide - Stainless)
233.51363200
(36" wide - Stainless)
233.51423200
(42" wide - Stainless)
w-
Z_
O
HBO027
,_
INTENDED FOR DOMESTIC COOKING ONLY,_
_1, CONCEBIDO SOLO PARA USO DOMC:STICO ,_
V05526 rev.D
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
if within 1 year from the date of instaflation, any part of this
range hood fails to function properly due to a defect in
material or workmanship,
Sears will repair the part or
furnish and install a new part, free of charge.
FULL 30-DAY WARRANTY ON FINISH ON PAINTED OR
BRIGHT METAL PARTS
if within 30 days from the date of installation, the finish on
any painted or bright metal parts of this range hood is
defective in material or workmanship, Sears will furnish
and install a new part, free of charge.
WARRANTY SERVICE iS AVAILABLE BY CONTACTING TH E
NEAREST SEARS SEVtCE CENTER/DEPARTMENT IN THE
UNITED STATES.
This warranty applies only while this product is in use in
the United States. This warranty gives you specific legal
rights and you may have other rights which vary from state
to state.
Sears, Roebuck
tL 60179
WARNING
A
WARNING
A
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
if you have questions, contact the manufacturer at the
address listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. InstaIlation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated codes and standards.
4. Sufficient
air is needed for proper combustion
and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Do not use this range hood with any additional solid state
speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RiSK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spilIovers that may
ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware
for the size of the surface element.
appropriate
A
and Co., Dept 817WA, Boffman
Estates,
A
TO REDUCE THE RiSK OF iNJURY TO PERSONS iN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. if the flames do not go out immediately,
EVACUATE AND CALL THE FiRE DEPARTMENT.
2. NEVER PiCK UPA FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
- This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray,construction dust, etc. off power unit.
3. Your hood motor has a thermal overload which wiI!
automatically shut off the motor if it becomes overheated.
The motor will restart when it cools down. if the motor
continues to shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the
hood should be a minimum of 24" and a maximum of 30"
above the cooking surface.
5. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside - Do not exhaust air into
spaces within walls or ceiling or into attics,crawl spaces, or garage.
6. This product is equipped with a thermostat which may
start blower automatically. To reduce the risk of injury and
to prevent power from being switch on accidentally, switch
power off at service panel and lock or tag service panel.
7. To reduce the risk of fire and electric shock, the Kenmore
ELITE 51000 Series hood must be installed with blower
models 51200, 51600, or 57745 only. Other blowers
cannot be substituted. (Blowers sold separately).
8. Use with approved cord-connection kit only.
9. Please read specification
label on product for further
information and requirements.
Always turn ON your hood before you begin cooking in order
to establish an air flow in the kitchen. Let the blower run for a
few minutes to clear the air after you turn off the range.
will help keep the whole kitchen cleaner and brighter.
=
This
O
4-EB
I
3
Warming
lamps
lamp switches
lights
filters
The grease filters should be cleaned frequently.
Use a warm
detergent
solution.
Grease filters are dishwasher
safe.
Wash more often
grease - like frying
4. Halogen light switches
5. ON/OFF Blower switch
6. Blower speed control
Lamps (Infrared)
if your cooking
style
foods or wok cooking.
Remove
filters by pushing filters
and rotating filters downward.
Blower
HCOO04K
1. Warming
2. Warming
3. Halogen
Grease
generates
towards
the
back
greater
of hood
Cleaning
Remove
the grease
filters
in order to access
the blower.
Vacuum blower to clean. Do not immerse
in water. Refer to
blower instruction manual for more details.
Grease
Rail
The grease
rail
baffle filters are
grease rail from
See illustration
should be cleaned
frequently,
especially
if
used. Remove filters, then, disassemble
the
the hood by removing
its 3 retaining screws.
below.
Each warming lamp (item 1 on picture above) is controlled
with is own ON/OFF switch (item 2 on picture above).
Use only BR40 Size, 250W Max., Infrared bulbs. (Purchase
separately.)
_._
ARNING:on warming
Do not
material
Cooktop
Lighting
place
shelves.highly
flammable
(Halogen)
A double set of ON/OFF
switches (item 4 on picture
control the halogen lights (item 3 on picture above).
The front rocker controls
controls both side lights.
best cooktop lighting.
the center
Select one,
above)
light. The rear rocker
two, or three lights for
Use PAR 20, 50W halogen
bulbs. (Purchase
Please refer to page 4 for ordering information.)
separately.
is operated
using
/%
_
/
,/
HD0069
/
"_
Refer to Stainless
steel cleaning
in Hood Cleaning
section
below. Once the grease rail is clean and dry, reassemble
it to
the hood and reinstall filters.
Blower
The blower
o
two (2) controls.
Use the ON/OFF
blower switch (item 5 on picture above) to
start and stop the blower. When turned on, the blower will
operate at the previous setting of the speed control (item 6 on
the picture above).
Hood
Turn the speed control
speed - counterclockwise
- Regularly wash surfaces with clean cloth or rag soaked
warm water and mild soap or liquid dish detergent.
knob clockwise
to decrease
to increase
speed.
blower
Cleaning
Stainless
steel cleaninq:
How to maintain
its "BRIGHT
LOOK"
Do:
with
HEAT SENTR_
- Always
Your hood is equipped
with a HEAT SENTR_
thermostat.
This thermostat
is a device that will turn on or speed up the
blower if it senses excessive
heat above the cooking surface.
- Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
1) If blower
is OFF
2) If blower
to HIGH
is ON at a lower
speed.
When
return
- it turns
the temperature
level
to its original setting.
blower
speed
drops
ON to high speed.
setting
- it turns
to normal,
blower
the blower
up
will
clean
in the diredtion
- You may also
use a specialized
WARNING: The HEAT SENTRY thermostatcan
start the blower even if the hood
TM is turned OFF.
When this occurs, it is impossible to turn the
blower OFF with the switch. If you must stop
the blower, do it from the main electrical panel.
polish
household
lines.
stainless
steel
cleaner.
Don't:
_"
- Do not
use any steel
scrapers
to remove
- Do not allow
or stainless
stubborn
- Do not use any harsh
,_
of original
stell
wool
or any other
dirt.
or abrasive
cleaners.
dirt to accumulate.
- Do not let plaster dust or any other construction
residues
reach the hood. During construction/renovation,
cover the
hood to make sure no dust sticks to stainless steel surface.
Avoid:
when
choosing
that contains
-Any products
containing:
surfaces
- Any combustible
acetone,
alcohol,
and should
3
--
a detergent
- Any cleaners
will deteriorate
--
bleach
chloride,
will attack
fluoride,
stainless
iodide,
steel.
bromide
_,
such as
explosive
_1
rapidly.
products
used for cleaning
ether, benzol,
etc., are highly
not be used close
to a range.
_,
m
_
Wood
mounting
PAR 20 50W
Light Bulb
(3 per hood)
Sears Part No. 57853
strip
Grease Filter
(3 per hood)
Parts Bag
(includes
4 fiat head screws #10-2",
8 screws #8-3/4", 4 Nuts #10-32,
2 Wall anchors and
2 Washers
3/16"
Warming
Lamp
BR40,
250W
Max.
(2
per hood)
(_
Ducting
Accessories
(See "51000
Series
Range
Hood
Ducting Accessory
Model Nos.)
(interior
5 for
System"
on page
5 for
OR exterior)
(See "51000
Series
Blower Model Nos.)
J
/
Q
Screwdriver
Drill
on page
ID x 3/4" OD)
Blower
(Robertson
System"
or Phillips)
Pencil
Sabre
Saw
-or-
Keyhole
Saw
Tape
Measure
Range
Hood
/
3/8"
Nutdriver
Wire
Duct Tape
Stripper
F
Wall & Roof Caps,
Exterior Blower
L
Sears Stock
Number
57745
Broan Model
437
1200 cfm
Exterior Blower
High
Roof
I
Broan Model
441
10" Round
Wall Cap
Capacity
Cap
Broan Model 647
7" Round
Wall Cap
\
i
©
--©
Adjustable
Cap
i
F
Broan Model
10" Round
Roof
/
I
I
Elbows and
In-Line Dampers
L
Sears Stock
Number
59091
418
Broan Model
7" Round
Broan Model 421
10" Round Vertical
Elbow
/In-Line
Adjustable
Damper
o_
415
Elbow
/
F
L
m
i
Ductwork
2
Broan Model 410
10" Round Duct
Broan Model 407
7" Round Duct
(2 ft. sections)
(2 ft. sections)
I
I
F
Choose 1 of 5
Discharge
Transitions
_
1
m
(
i
I
(b
Broan
I Broan
I
Model 427
(4½"x18½"
i
tol0"Rd.,
6" high - lateral)
Model
423
(4 ½" x 18 ½" to
10"Rd.,
-vertical)
I
\
Broan
Model
424
Broan
Model
454
Broan
Model
(4 ½" x 18 ½"
tol0"Rd.,Horiz,
(4 ½" x 18 ½"
tol0"Rd.,Horiz,
(4 ½" x 18 ½"
tol0"Rd.,Horiz.
front - rear)
Horiz. / right)
Horiz. / left)
453
L
\
i
i
i
i
\
\
\
mSears
Sto_
Number 58140
Optional Soffit Chimney
_
__
Rough-in Kit
(Use with Exterior
Blower Model 57745)
//
(30")
(36")
Stock Numbe_
(42")
//
f-
-_ J
rs Stock
_
"_
Number 51600
Blower/
/ Rough-in Kit
(600 cfm Interior
Blower and
_
_JJ_J
Rough-in
Choose 1 of 3
Blower Systems
L
55130
55136
Sears
55142
51000
Sears Stock Number 51200
Blower / Rough-in Kit
(1200 cfm Interior Blower and
Rough-in
Plate)
SEARS STOCK NUMBERS
available through your local
Sears store, on line at Sears.com,
or from Sears Parts
at 1-800-366-7278.
For availability
of Broan Models,
pease
ca
1-800-558-1711.
(Canopy
controls
Series
Plate)
Hood
with blower _
& lighting.
_-._
Required
for all
installations.)
Optional
Baffle Filters
_
Optional Backsplash
Sears Stock Number
57130 (30"), 57136 (36"), 57142
(Stainless
steel wall covering
with warming
shelves.)
O_
Sears
Stock
Number
50030
50036
50042
(30")
(36")
(42")
HL0032
(42")
Cb
Kenmore
rangehoodsaredesigned
toperform
efficiently
whenattached
tolongrunsofduct.Asa pointofreference,
thishood
willfunction
atapproximately
80%ofitsratedairperformance
when100equivalent
feetof7"roundductwork
isattached
(for
600cfmblowers)
or 125equivalent
feetof10"roundductis attached
(for1200cfmblowers).
Usethischarttocalculate
the
equivalent
ductlengthofyoursystem.
Notethat7"roundistheminimum
recommended
ductsizefor600cfmblowers,
and10"
roundistheminimum
recommended
ductsizefor1200cfmblowers.
Broan Model 424
4 V2-in. x 18 1A-in. to
10-in. Round - Horiz.
Broan
Model
407
Straight Duct
7-in. round x 2-ft. long
Equivalent
length
7-in. Round
Front / Rear Transition
Equivalent
length
Wall Cap
Equivalent
Broan
Modellength
647
10ft.
30 ft.
(15-ft.
w/o damper)
2ft.
Broan Model 454
4 V2-in. x 18 1A-in. to
10-in. Round - Horiz.
Right Transition
Equivalent
length
Broan
Model
410
12ft.
Straight Duct
10-in. round x 2-ft. long
Equivalent
length
2ft.
40 ft.
(25-ft.
wio damper)
Broan Model 441
10-in. Round
Broan Model 453
41A-in. x 18 Y2-in. to
10-in. Round - Horiz.
Left Transition
Equivalent
7-in. Round Elbow
Broan
Modellength
415
Equivalent
Broan Model 437
10-in. Round
Roof Cap
_uivalent length
length
Wall Cap
Equivalent
length
40 ft.
(25-ft.
w/o
damper)
12ft.
8ft.
10-in. Round Elbow
Broan Model 418
Equivalent
length
10ft.
Sears
Model 59091
Roof Cap
(7-in. round)
Equivalent length
30 ft, (7-ft. w/o damper)
Broan Model 427
4 4/2-in. x 18 'A-in. to
10-in. Round, 6-in. High
- Lateral Transition
Equivalent
length
2ft.
Broan Model 423
41A-in. x 181A-in. to
10-in. Round - Vertical
Transition
Equivalent
2ft.
length
EARS STOCK
NUMBERS
available
through your Ioca_
ears store, on line at Sears.com,
or from Sears Parts at I
1-800-366-7278.
For availability
of Broan Models,
I
please call 1-800-558-1711.
I
1. The Kenmore
Elite Series hood must be installed
with
interior blower models 51200
or 51600, or exterior blower
57745 only. Other blowers cannot be substituted.
(Blowers
sold separately.)
Plan where
and how the ductwork
Install proper-sized
ductwork,
roof or wall cap for the model
For best results,
and elbows.
transition(s),
elbow(s),
and
of blower you are using.
use a minimum
ROOF
will be located.
number
Dimensions
below.
for the most common
are shown
Adjust your measurements
for various heights of ceilings,
soffits, cabinets or cooktops.
For proper
operation,
the
hood must be a minimum
of 24" and a maximum
of 30"
above the cooktop.
Standard
8 ft. (2.44 m)
ceiling
of transition
19"
O_
Top of wood
mounting strip
WALL
CAP
(305
_
H°°d X
HOOD
m
ROUND
ELBOW
m
t
571 Series
Backsplash
(optional)
24" TO 30" (609 to 782 mm)
ABOVE
COOKING
SURFACE
HH0_24A
MODEL 51600 SINGLE BLOWER
TYPICAL DUCTWORK
ROOF
24"
(610 ram)
I
Minimum distance
between the hood and
_l_
I
the cooktop
Cooktop
10" (254 ram)
ROUND
DUCT
H cooktop HHOO28A
INSTALLATION WITH STANDARD 18" HIGH
OVER-COOKTOP CABINET
DECORATIVE
WALL
CAP
m
m
C3
(305
4-1/2" x 18-1/2"
to 10"
(114 x470to
ROUND
HOOD
O
=
-- Standard 36"
(914 mm)
CAP
\
FLUE
or SOFFIT
m
(483 mm)
DECORATIVE
I
m
CAP
7" (I78 ram)
ROUND DUCT
FLUE
or SOFFIT
installations
Standard
8 ft. (2,44 m)
ceiling
Standard
12"(305ram)
soffit
13"
t
24" TO 30" (606
ABOVE
COOKING
(33mm)O
to 762 i'qrn)
SURFACE
MODEL 51200 DUAL BLOWER
TYPICAL DUCTWORK
EXTERIOR
|
Hood
]
X
Top of wood
mounting strip
BLOWER
--
10"(254mm)
ROUNDDUCT
l
571 Series
I _
Backsplash
optional)
DECORATIVE
FLUE
or SOFFIT
30"
(762 mm)
10" (254 ram)
(305
EXTERIOR
) BLOWER
Maximum
distance
between the hood and
the cooktop
58140
HOOD
ROUGH-IN
_
Cooktop
KIT
t
Standard 36"
(914 mm) H
cooktop
HHOO27A
INSTALLATION WITH 12" SOFFIT OR
OPTIONAL SOFFIT CHIMNEY 551 SERIES
24" TO 30" (609 to 762 mm)
ABOVE
COOKING
SURFACE
MODEL 57745 EXTERIOR BLOWER
TYPICAL DUCTWORK
--
/
J
(b
1.
Using
a Phillips
#2 or a Robertson
#2 screwdriver,
unscrew the hood from the bottom of crate. Refer to figure
to the right to locate all 4 screws. Discard these screws
and remove hood from wood pallet.
4.
0,
O_
Oo
O_
.1
2 •
o
o
HR0002
I OPTION
I
A Backsplash
is available (see page 5 for more details). This
backsplash
must be installed before the hood shell because
the hood shell covers the backsplash
top mounting
screws.
In order to be able to install the backsplash,
make sure you
have at least 18" (457 mm) clearance
between
bottom
of
hood and range control panel or cooktop. (Refer to instructions
included
with backsplash.)
2. Measure
and mark a level line on wall above cooktop
location
for the wood mounting
strip (see illustrations
to the right and under step 2 on page 7). Use #10-2"
flat
head screws (included in the parts bag) to secure the mountto the drywall. Make sure to hit the wall studs.
CAUTION: Due to the weight of this hood,
ensure that the wood strip is attached to all of
the available wall studs (2 studs minimum for
the 30" hood, more as hood width increases);
not into drywall alone.
t3" (330 ram) or
19" (483 ram) from
ceiling see page 7
(38 mm)
HD0068A
1.
2.
3.
4.
5.
6.
Drywall
Wood Mounting Strip
Flat Head Screw
Wall Anchor Location
Outline of the Back of the Hood
Wall Studs
1.Restthebackcavityofthehoodonthewoodmounting
strip.
4_5 CAUTION:
secured
Hold the
to the wood
Top of hood (inside view)
until it is completely
mounting strip.
hood
Mounting
Secure hood to wood strip with (4) screws
#8 - 3/4" (for
30" and 36" width hoods) or (6) screws (for 42" width hood)
provided
at location
shown. Drill (2) 3/16" size holes into
the drywall for wall anchors through the existing holes in
the inside hood back in the locations shown. Then install
screw locations
m
m
the (2) wall anchors
and attach the hood to these anchors
with the remaining #8 - 3/4" screws
and the (2) washers
provided.
O}
HD0064
2. Attach
Refer
transition
(if required)
to blower rough-in
to page 5 for available
model numbers.
Use duct tape
to make
all joints
secure
and
plate.
m
air-tight.
m
Model 51600 blower plate connects directly to 7" round duct
without
a transition.
Exterior
blower
model
57745
utilizes
a model
58140
mounting plate which connects directly to 10" round ductwork
without
a transition.
HD0049
m
m
3. Run power cable to installation
location.
Refer to the
instructions
included with the selected
blower
/ rough-in
kit (sold separately)
for details on installing
the rough-in
plate, install the rough-in
plate so that the wiring box is
located on the right side as you are facing the hood.
t3
For ducting through back of hood, remove existing
plate
from inside back of hood and attach to inside top of hood
to cover hole. Secure
to threaded
studs with same (4)
nuts.
For ducting through top of hood,
place on inside back of hood.
existing
Connect
ducting to transition
or rough-in
installing
the rough-in
plate. Use duct
joints secure and air-tight.
plate remains
in
plate as you are
tape to make all
HD0063
O}
9
m
1. Remove
_i
wiring mustRisk
WARNING:
be done
of electrical
by qualified
shock. personnel
Electrical
in accordance with all applicable codes and
standards. Before connecting wires, switch
power off at service panel and lock service
disconnecting means to prevent power from
being switched on accidentally.
wiring
cover from
S_o
3. Connect BLACK to BLACK,
or bare wire under GREEN
cover.
FAN MOTOR
RIGHT HEAT LAMP SOCKET
NEMA
_15PPLUG
% THE
HS
RMOST_T _B
W
R,GHTL,GHT
W
SOCKET
L:NT_CCKE]
°Ow
B
LEFT LIGHT SOCKET
LAMP SWITCH
"___
i
W[
HE0018
I OPTION
w
W
I
I
A Soffit Chimney is available - to hide ductwork
if the hood
is not installed under a cabinet. Refer to the instructions
included
with
the soffit
chimney.
Refer to page 5 for ordering
I
information.
J1
1. To install blower, refer to instructions
included with blower
/ rough-in kit. Once the blower is installed, plug the blower
unit into the female receptacle
and the power supply onto
the male connector
inside the hood. DO NOT plug the two
cords into each other.
I
See page 5 for blower / rough-in
kit information.
]
HE0003
2. Install (2) heat lamp bulbs. Use BR40 size, 250W Max.,
infrared
bulbs only (purchase
separately).
Install
(3) halogen
light bulbs.
Use PAR20
50W size
(purchase
separately).
See page 4for bulb information.
Refer to page 12 for ordering information.
10
plate and set aside.
2. Remove appropriate
knock-out
from rough-in plate. As you
are installing
the rough-in
plate, feed 6" of power cable
through knock-out
opening
and attach cable to wiring box
with appropriate
connector.
RIGHT HEAT LAMP SWITCH
120V 60Hz IN
rough-in
WHITE
ground
to WHITE and GREEN
screw. Reinstall wiring
_
AUTION:
filters
beforeRemove
installingprotective
them. plastic film covering
It is recommended
to install side filters first and finish with
center one.
1) insert upper end of filter into the hood (finger sized cup
side).
2) Raise lower end toward the inside of hood.
3) Position rear part of filter into channel and pull.
4) Using finger sized cup, pull on the upper end of filter and
slide it under the front inner retaining
piece.
m
m
O_
m
m
2
HD0065
m
m
13
HD0024
I
Refer
I OPTION
Replacement
filters are available.
to page 12 for ordering
information.
I
I
I
Baffle filters are available. To order them, refer to the table
below to find the right filter kit number for your hood. to
install them, refer to instuction
sheet included
with baffle
filter kit.
I
Referto
KIT #
50030
50036
50042
page 5fororderinginformation.
I
HOOD
WIDTH
30"
36"
42"
O_
11
m
0
20
I
17
\
18
HL0031
KEYNO,
1
2
3
4
5
6
7
PARTNO.
V05529
V02264
V02773
V02772
V03435
V03436
V02563
V03502
V03503
10
11
12
13
14
15
V03504
V03501
V03505
V03517
V03519
V03520
V00673
V02512
V01869
KEYNO,
16
17
DESCRIPTION
Kenmore Elite Logo
Porcelain Lamp Socket
Male Motor Connector
Female Motor Connector
Thermostat
Thermostat Bracket
SPST Single Switch for
Heat Lamps
SPST Double Switch for
Halogen Lights
SPST Lighted Single Switch
for Blower
PARTNO.
V01582
V05522
V05523
V05524
18
19
2O
21
22
Speed Control Button
Speed Control
Terminal Block
Power Cord
Control Wire
Lighted Switch Wire
Lock Nut 8-32
Machine Screw 8-32 x t½ Quadrex
Machine Screw 6-32 x _/4Pan Quadrex
**
*
V14763
V14764
V14765
V05528
V05521
V14744
V14745
V05526
V12971
V02544
Order replacement
DESCRIPTION
Lock Nut 6-32
Sq. Perf. Grille Filter for 30" Hood
9.5 x 15.25 x 0.355 (3 required)
Sq. Perf. Grille Filter for 36" Hood
11.61 x 15.25 x 0.355 (3 required)
Sq. Perf. Grille Filter for 42" Hood
13.61 x 15.25 x 0.355 (3 required)
Grease Rail 30"
Grease Rail 36"
Grease Rail 42"
Filter Spring 5.265" x 0.350"
Sealing Extrusion 20.625"
Left Side Liner
Right Side Liner
Manual for Kenmore Elite
Installation Bag (Flat head screws
#10 x 2" (4), Screws #8 x 3/4" (8),
Nuts #10-32 (4), Wall anchors (2),
Washers 3/16" I D x 3/4" OD)
Halogen Lamp PAR20 50W
Heat Lamp BR40, 250W max.
parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased
** Not illustrated.
12
locally.
Your Home
For repair-in
your home-of all major brand appliances,
lawn and garden equipment, or heating and cooling systems,
no matter who made it, no matter who sold it!
::::::::::::::_
iiiiiiiiiiiiiiiii
For the replacement
parts, accessories
and
owner's manuals that you need to do-it-yourself.
For Sears professional installation of home appliances
and items like garage door openers and water heaters.
'_
::::::::::::::_
HHHHHHHHi
i
1-800-4-MY-HOME
Call anytime,
®
(1-800-469-4663)
day or night (U.S.A. and Canada)
www.,ear,.com
www.,ear,.ca
Our Home
=_
iiiiiiiiiiiiiii
iiiiiiiiiiiiiiiii
For repair of carry-in items like vacuums, lawn equipment,
and electronics, call or go on-line for the location of your nearest
--
Sears Parts & Repair Center.
1-800-488-1222
Call anytime,
day or night (U.S.A. only)
w_,,.,ears.com
To1:urchase
pr°tecti°n800
827 t 6655 (U.S.A.)agreement
,,,,,,,,,,,,,,,
_"
on prod.uctl
1 800 361serviced6665
(Canada)bY
Sears:
__-u_
Para pedir servicio
a domicilio,
de reparaciOn
y pare ordenar
Au Canada
pour service en fran(_ais:
_"
1.800.LE.FOYERMC
piezas:
1"888"SU'HOGARSM
(1-800-533-6937)
www.sears.ca
(1-888-784-6427)
,,,,,,,,,,,,,,,
o"
:=
i
TM
® Registered Trademark /
Trademark / SMService Mark of Sears, Roebuck and Co.
® Marca Registrada / TM Marca de Fabrica / SM Marca de Servicio de Sears, Roebuck and Co.
MC
Marque
de commerce
/
MD
Marque
deposee
de Sears,
Roebuck
and Co.
13
® Sears,
Roebuck
and Co.
SECCI6N
PAGJNA
Si dentro de 1 abe de Ia fecha de la instalaci6n, cuaJquier parte
de esta campana de cocina deja de funcionar
en forma
Garantia.................................................................................
14
apropiada debido a defecto en ei material o la mane de obra,
hstruccionesde seguridad..................................................
14
Sears repararA Ia pieza afectada o proveerA e instalara una
©peraci6n ..............................................................................
15
pieza nueva libre de cargo.
GARANTIA COMPLETA DE 30 BiAS EN EL ACABADO EN
Limpieza ................................................................................
I5
PJEZAS MET.,_LICAS PJNTADAS O ABRILLANTADAS
Piezas incluidas
....................................................................
16
Piezas non incbidas .............................................................
Herramientas necesanas .....................................................
16
16
Sistema de ia campana Serie 51000 ...................................
Cuadro de equivalencia de largo de conducto ...................
Prepare Ia Iocalizaci6n para la campana ............................
Prepare la campana .............................................................
Instab la campana ................................................................
Conecte et cabIeado .............................................................
17
18
19
20
21
22
Si dentro de 30 dias de la fecha de Ia instalacidn, el acabado de
cualquier parte metAlica pintada o abrillantada perteneciente a
esta campana de cocina aparece con defecto en el material o
la mano de obra, Sears proveerA e instalarb, una pieza nueva
libre de cargo.
EL SERVICIO DE GARANTIA SE OBTJENE PONtg:NDOSE EN
CONTACTO
CON
EL CENTRO
DE SERVICJO
O
DEPARTAMENTO SEARS M.,_SCERCANO EN LOS ESTADOS
UNIDOS.
Esquema eI6ctrico ................................................................
Terminar Ia instalaci6n ..........................................................
Instab los filtros ....................................................................
Piezas de servicio .................................................................
22
22
23
24
Esta garantia es vaiedera unicamente si este producto se tiene
en uso dentro de los Estados UnJdos, Esta garantia le confiere
derechos Iegales especificos y Ud. puede tener ademb, s otros
derechos que vadan de estado a estado.
Sears, Roebuck and Co., Dept. 817WA, Noffman Estates, IL 60179
ADVERTENCIA
ADVERTENCIA
PARA REDUCIR EL RmESGO DE INCENDtO, CROQUE ELECTRmCO, O
LESION A PERSONAS, PROCURE LO SIGUIENTE:
1. Utilice esta unidad s61o en ia manera prescrita pot el fabricante. Si
fiene usted alguna pregunta, comuniquese
con el fabricante a la
direcci6n indicados en la garantia.
2. Antes de efectuar aigOn servicio o iimpieza, se debe desconectar la
corriente electrica en el armario de circuitos y asegurarlo con IIave
para evitar que ta corriente sea conectada accidentalmente.
Cuando
el dispositivo
para desconectar
ei servicio electrico no puede ser
cerrado con algQn tipo de traba, sujete fuertemente al panei de servicio,
una etiqueta de advertencia prominente.
3. Todo trabaio de instaIaci6n y cableado eiectrico debe ser reaJizado
por personal calificado y de acuerdo con todos los c6digos y normas
pertinentes,
incluyendo
los c6digos y normas reiacionados
con
construcci6n
clasificada para incendio.
4. Aire suficiente es necesario para facilitar Ia combusti6n adecuada y
la salida apropiada de gases por Ia chimenea de Ia unidad y para
evitar corrientes de aire invertidas. Siga las instrucciones y medidas
de seguridad
deI fabricante
dei equipo y ios publicados
por la
Asociael6n nacionaI de protecci6n contra incendidos (NFPA pot sus
siglas in Ingles), y la Sociedad americana de ingenieros de calefacel6n,
refrigeraci6n y aire acondielonado (ASHRAE por sus siglas in Inglg, s),
y los reglamentos de seguridad locales.
5. Acortaroperforariaparedoeltecho,
noda_eelcableadoei6ctrico
ni otros servicios pObticos ocuitos a la vista.
6. No utilice este ventilador con ningQn dispositivo de una control de
veloeldad de estado s6iido adicionaL
7. Los abanicos con ducto deber_Snsiempre tener una salida hacia el exterbr.
8. Para reduelr el riesgo de incendio, use s61o ductos de metal
9. Esta unidad se debe instalar con tierra efectiva.
PARA REDUCIR ELRIESGO DE INCENDIO DE GRASA EN LASUPERFICIE
DE LA ESTUFA:
1. Nodejenuncalosaparatosdecocersin
vigilenciaafuegovivo.
Los
desbordamientos
producen humo y derrames grasiendos que pueden
inflamarse. Caliente e! aceite despacio, a fuego lento o mediano.
2. Ponga en marcha siempre la campana al cocinar a temperaturas elevadas
o aI cocinar alimentos flameados.
3. Limpieconfrecuencialosventiladores.
Nodebepermitirquelagrasa
se acumule en el ventilador ni en el filtro.
4. Utilice un sart6n de tama_o adecuado. Siempre
adecuado aI tamaBo del elemento de superficie.
utilice el utensilio
_
_,
PARA EVITAR RESGO
DE LESIONES PERSONALES
EN CASO DE
INCENDIO DE GRASA EN LASUPERFICE
DE LA ESTUFA, OBSERVE
LO SIGUIENTE:*
1. Cubra y sofoque las ilamas con una tapa aiustada, azafate de hornear
gailetas, o azafate de metal, y luego apague el calentador. TENGA
CUIDADO PARA EVITAR QUEMADURAS.
Si tas llamas no se apagan
inmediatamente, HAY QUE EVACUAR Y LLAMAR LOS BOMBEROS.
2. NUNCAALCE UNASARTf_N QUETENGALLAMAS -Usted se puedequems_se.
3. NOUTILICEAGUA,
incluyendotrapos,
lavaplatos mojadosotoatlas_
puede que occuran explosiones de vapor vioIentas.
4. Utiibe un extinguidor SOLAMENTE si:
A. Usted sabe que tiene un extinguidor de clas ABC y !o sabe utiIizar.
B. El incendio es peque_o y contenido dentro det area donde se inici6.
Q Los bomberos han eldo avisados.
D. Usted puede combatJr e! incendio con una salida a su espalda.
* Basado en tas recomendaciones
para "Seguridad
en la Cocina"
pubticadas pot la NFPA de Ios EEUU.
PRECAUCION
I. S61o para uso de ventilaci6n
general.No se use para extramateriales
o vapores peligrososo explosivos.
2. Para evitardaBos alcojinentedeJ motor y/o impulsores ruidososo
desequilibrados,mantenga lafuentede potencialejosde roeiosde
pared seca, de polvode construeci6n,
etc.
3. Elmotor delacampana tieneun dispositivo
contrasobreeargast6rmicas
que apaga elmotor en forma automatica si@ste se sobrecalientaEl
motor volver&arrancarcuando se enfrie.
Sielmotor sigueapagandose,
haga verificar Ia campana.
4. Para !ograr una mejor captura de las impurezas producidas al coelnar,
la parte inferior de la campana deber_ estar a un minimo de 24" y un
m_4ximo de 30" sobre el nivet Ia superficie para cocinar.
5. A fin de reducir los riesgos de incendJo y para bien evacuar el aire de salida,
&seg{Srese de evacuar el aire elexterior _No evacue el aire en espasies lim_dos
c_omoel intedor de la paredes o deltecho e en el desvb_n,falso techo o garaje.
6. Este producto esta equipado de un termostato que puede hacer partir et
ventitador automaticamente.
Para evitar los riesgo de da_o, apague ta
corrbnte de panel el6ctrico y elerre con candado o afiche una adver[anela
en et panel para prevenir que la campana funcione automaticamente.
7. Para reducir et riesgo de incendio y descarga electrica, este campana
Kenmore Elite Series 51000 debe ser instabda con ventiladores modebs
51200, 51600 o 57745 solamente. Otros ventiladores no debe ser utilisado.
(Ventiladores vendidos separadamente.)
8. Utilice s61o con un conjunto autorizado
de conexi6n con cord6n.
9. Por favor, Iea la etiqueta de espeelficaciones en el producto para mayor
14
informaci6n y requisito.
Siempre
hacerfuncionar
lacampana
antesdecomenzar
a
cocinar
afindeestablacer
unacirculaci6n
deaireenlacocina.
Dejeigualmente
funcionarla campana
algunosminutos
despues
dequeparedecocinar
afindelimpiar
elaire.Esto
ayudaa concervar
lacocinamaslimpiay unairepuro.
O
4-E"
=
para grasa
Limpie frecuentemente
los
detergente
suave. Los filtros
I
Limpie mas seguido si su comida crea
fritura o preparar
la comida con wok.
Limpieza
agua
lavar
caliente
y un
en lavaplatos.
mucho
grasa
- come
del ventilador
Quitar los filtros para grasa a fin de que tener acceso
al
ventilador.
Pasar la aspiradora
en el ventilador
por limpiar.
No permita
la entrada
de agua en el ventilador.
Para m&s
informacion,
refierse a el manual del ventilador.
2
HCOOO4K
1. Lamparas tormogenas
Interruptores
de lamparas termogenas
Luces hal6genas
Interruptor
de luces halogenas
Interruptor
de encender/apagar
del
Control de velocidad
del ventilador
filtros con
se pueden
Empuje los filtros hacia el interior de la campana
y leberelos
del canal para queen
seguida los retire de la campana.
3
2.
3.
4.
5.
6.
Filtros
Canal
Limpie frecuentemente
el canal, sobre todo si utilice los filtros
de zig zag. Quite los filtros, despues
dejunta el canal de la
campana
en quita los 3 tornillos.
Ver dibujo de abajo.
ventilador
L_mparas
termog_nas:
Cada
I&mpara
es controlada
independientemente
con su propio
interruptor.
Utilice
las
bombillas
infrarrojas
(BR40, 250W max.)
t,
_,_
No dejar
materias
enDVERTENClA:
los estantes
que
calientan.
Luces hal6genas:
Los dos interruptores
controlan
las luces hal6genas.
t,
inflamables
de encender/apagar
El interruptore
a bascula antes, controla la luz del centro. El
interruptor
detras controla las luces de cada lado. Encenda
una, dos o tres luces segQn su necesidad.
Utilice las bombillas
de halogenas
PAR 20, 50W (comprar
separadamente;
refierse
a la p&gina 4 para informacion
sobre pedido).
Ventilador:
El ventilador
Utilice el interruptor
encender
y apagar
ventilador
funciona
funciona
/
/
,/
/'
con la ayuda de dos controles.
endender!apagar
tiene una luz roja para
el ventilador.
Cuando est& en tension, el
a la velocidad
utilizada la 01tima vez.
HD0069
l
Yea Acero inoxidable
en la parte Limpieza
de la campana
abajo. Una vez que el canal este limpio y seco, instale en la
campana
y instale los filtros.
Utilice el control de velocidad
del ventilador
girando
en el
sentido de las agujas del reloj para disminuir
la velocidad
y
en el sentido contrario de las agujas del reloj para augmentar
la velocidad.
Limpieza
HEAT SENTRY "rM
- Lavar regulamente
la superficie
con un trapo o un paso
empapado de agua tibia y de jab6n suave o detergente a vajilla.
Su campana
esta equipida
con
termostato
tiene
un mecanismo
acelerara
el ventilador
si se detecta
de la cocina.
1) Si el ventilador
maxima.
esta apagado
2) Si el ventilador
esta encendiro
se pendera
a una velocidad
HEAT SENTRY TM. Este
que se encender&
o
un calor excesivo encima
- el se pender&
a una velocidad
Acero
de la campana
inoxidable:
Lo que debe
Como
minima
- el
Cuando
la temperatura
disminuye
a un nivel
ventilador
vuelve a la funcion de origen.
normal,
el
ADVERTENClA: El HEAT SENTRY termostato
puede comenzar a funcionar
alTM igual si la
campana esta parada. Cuando este situacion
ocurre, es imposible parar el ventilador con
los interruptores.
Si usted para la campana,
halago a partir del p_nel el_ctrico principal.
una
"aparencia
brillante"
- Siempre limpie en el sentido de las lineas originales de pulimento.
- Siempre enjuague bien con agua limpia (2 a 3 veces) despues
de haber limpiado
seque completamente
la superficie.
- Usted
puede
especialmente
a una velocidad
maxima.
mantener
hacer:
Lo que no debe
utilizar
un limpiador
domestico
para el acero inoxidable.
ta
hacer:
- No utilice
todo otto
ninguna
raspador
- No utilice
ningun
- No deje
hecho
lana de acero o de acero inoxidable
para quitar la suciedad tenaz.
limpiador
la suciedad
en polvo
abrasivo
o
O,
o riguroso.
acumularse.
- No deje el polvo de yeso o todo otro residuo de construccion
que caiga en la campana,
cObrala durante el trabajo para
asegurarse
queen
ningQn caso el polvo se pegue
a la
superficie
del acero.
A evitar
cuando
elige
u
un detergente:
- Todos los productos
de limpieza que contienen
blanqueo;
van a deteriorar
el acero inoxidable.
-Todos los productos
o bromuro;
estos
m
agentes
de
que contienen cloruro,
fluoruro,
yoduro
deteriorans
r&pidamente
las superficies.
ta
ta
t,a
- Todos los productos
acetona,
alcohol,
15 expl°siv°s
combustible
6ter, benzol,
Y no deben
utilizados
para la limpieza:
etc...; son extremamente
ser utilizados
cerca
de una cocina.
R"
6"
Tira
Bombillas
PAR 20 50W
(3 para campana)
Sears Pieza No. 57853
de madera
.....
Filtros para grasa
(3 para campana)
BR40, 250W Max.
L_mpara
termog_na
(2
para campana)
(_
Accesorios
Bolsa de piezas
(incluye 4 tornillos #10-2",
8 tornillos #8-3/4", 4 tuercas #10-32,
2 anclas de la pared y
2 arandelas
3/16" ID x 3/4" OD)
de conducto
(Yea "Sistema
de campana
51000 Series" en la p&gina 17
para vear los nQmeros de modelo de accesorio
de conducto.
Ventilador
(interior
o exterior)
(Yea "Sistema
de campana
51000 Series" en la p&gina
para vear los nQmeros de modelo del ventilador.)
/
/
Q
Detornillador
(Robertson
Perforadora
o Phillips)
Cinta
m_trica
L&piz
/
Herramienta
para apretar
tuercas
de 3/8"
Sierra de
Segueta
- - o vaiven
Cinta adhesiva
a conducto
16
Herramienta
para quitar
la funda
17
63
F
Remates de
pared o de techo,
Ventilador exterior
L
Nt_mero Sears
57745
Ventilador
Exterior
1200 pcm
Modelo
437
Broan
Modelo
441
Tapa del techo
Alto rendimiento
I
Modelo Broan
Tapa del muro
7" Redando
\
Tapa del muro
10" Redonda
I
F
Broan
647
Nt_mero Sears
59091
Tapa del techo
.j
J
J
m
m
I
Codes y
Compuerta
de tira
J
L
Modelo Broan 418
Coda ajustada
de
10" redanda
Modelo
Modelo Broan 421
Compuerta
de tira
en linea vertical de
10"
Broan
415
Codo ajustado
7" Redondo
de
I
J
v
m
m
F
L
2
Conductos
Modelo Broan 410
Conducto
redondo
de 10"
Modelo Broan 407
Conducto
redondo de 7"
(Secciones
(Secciones
F
Elegir 1 de 5
transici6ns
r
/7
/
de 2 pies)
I
I
de 2 pies)
T
O,
m
m
¢
I
I Modelo
Broan 427
Modelo Broan 423
(4 ½" x 18 ½" a
Modelo Broan 424
(4 ½" x 18 ½"
Modelo Broan
(4 ½" x 18 ½"
454
Modelo Broan
(4 ½" x 18 ½"
I (4 ½" x 18 ½"_ 0" Rd.
- vertical)
a 10" Rd., Horiz.
a 10" Rd. Horiz.
a 10" Redanda,
i'--.)a10''
6 a tura
Reaenae,
- _tera
1'
frente
Horiz. / derecha
Heriz. i izq.)
- itr,s
)
453
Hariz.
N
Chimenea de intr&dos
opcional nt_mero Sears
55136 (36")
55142 (42")
55130 130")
_
Nt_mero
Sears 58140
Placa del ventilador
(Utilice
exterior
con el ventiladar
modelo
57745)
Elegir 1 de 3
sistemas de ventilador
L
__._
"--_1_
/_
\
I
_
_
\
\
\
Sears, en linea en Sears.com,
o per Piezas Sears al
disponibilidad par de
los modelos
J 1-800-366-7278.
OMERO SEARS Por
sonla disponibles
su local
tienda
de Braan, Ilamar al 1-800-558-1711
per favor.
//
_J-_Ventilador
/ Placa
o Sears 51600
_
_
del ventilador
_
_
_J-_
Nt_mero Sears 51200
Ventilador
/Placa
del ventilador
(Ventilador
interior de 1200 pcm y
placa del ventilador)
J
/__
('_'_)
Campana
51000 Series
(Pabellon
con controles
del ventilado y
iluminacion.
Se
requiere
para todas
las instalaciones.)
_
de 600 pcm y
placa del ventilador)
(Ventilador interior
m
u
Filtros de zigzag
Nt_mero Sears
50030 (30")
50036 (36")
50042 (42")
Placa salpicadura
opcional
N_mero Sears
57130 (30"), 57136 (36"), 57142 (42")
(Cubierta
para pared, de acero inoxidable,
con estantes
para calentamiento.)
17
HL0032
N
F,"
Las campanas
Kenmore
son hecho para cumplir un buen rendimiento
cuando son junta a conducto
largo. Como referencia,
este campana
funciona
aproximadamente
con 80% de su prestaciones
de aspiracion
cuando una equivalencia
de 100 pies
de conducto
redondo de 7" este junto (para un ventilador
de 600 pcm) o una equivalencia
de 125 pies de conducto
redondo
de 10" este junto (para un ventilador
de 1200 pcm). Empleo este cuadro para calcular
la equivalencia
de largo de conducto
para su sistema. Fijense bien que uno conducto
redondo de 7" es el tamaSo minimo por un ventilador
de 600 pcm y que uno
conducto
redondo de 10" es el tamaSo minimo por un ventilador
de 1200 pcm.
Modelo
Modelo Broan 407
Recto conducto
7 pul.
Equivalente
redondo x 2 pies de
largo
Equivalente
largo
Modelo
0
Tapa del muro
redondo de 7 pul.
Equivalente
Modelo
Broan largo
647
(_
30 pies
largo
(15 pies sin
compuerta
de tira)
10 pies
2 pies
(
Broan 424
4 1Apul. x 18 1Apul. a
10 pul. Redondo - Horiz.
transici6n
frente / atr&s
Broan
Modelo Broan 437
Tapa del techo
redondo de 10 pul.
Equivalente
largo
454
4 1A pul. x 18 1A pul. a
10 pul. Redondo
- Horiz.
transici6n
derecha
Equivalente
Modelo Broan 410
Recto conducto
40 pies
largo
(25 pies sin
compuerta
de tira)
12 pies
10 pul.
redondo
x 2 pies de
largo
Equivalente
largo
2 pies
_)
Modelo Broan 415
Codo redondo de 7 pul.
Equivalente
Modelo Broan 441
Tapa del muro
redondo
de 10 pul.
Equivalente
largo
Modelo Broan 453
4 V2 pul. x 18 1Apul. a
10 pul. Redondo - Horiz.
transici6n
izquierda
Equivalente
largo
40 pies
(25-ft.
w/o
damper)
12 pies
largo
8 pies
Modelo
Codo redondo
Modelo Broan 418
de 10 pul.
Equivalente
largo
10 pies
Modelo Broan 427
4 tA pul. x 18 1A pul. a
10 pul. Redondo, 6 pul.
alturatransici6n
lateral
Equivalente
largo
Broan
sin compuerta
de tira)
NUMERO
SEARS son disponibles
por su local tienda
Sears, en line& en Sears.corn,
o por Piezas Sears al
1-800-366-7278.
Por la disponibilidad
de los modelos
de Broan,
amar a 1-800-558-1711
por favor.
2 pies
423
4 tA pul. x 18 tA pul. a
10 pul. Redondo transici6n
vertical
Equivalente
59091
30 pies
(7 pies
Modelo
Sears
Tapa del techo
(7 pul. redondo)
Equivalente
largo
largo
2 pies
18
i
i
1.
La campana
Kenmore
Elite Series
51000
debe ser
instalada
con ventiladores
modelos
51200,
51600
o
57745
solamente.
Otros
ventiladores
no debe ser
utilisado.
(Ventiladores
vendidos
separadamente.)
Planifique
donde y como se van a colocar los conductos.
Instale ductos, transiciones,
codos y remate de pared o
de techo de tamaSo adecuado
para el tipo de ventilador
que este usando. Utilizar un minimo de transicion
y codos
per obtener el mejor resultados.
A continuacion
instalaciones
se
m&s
la campana
30" sobre
dimensiones
para
las
z.g
deber&
estar
entre
24" y
el nivel
de la superficie
para
un m_ximo
cocinar.
:_
de
Techo
Gabinete
I
est_indar
8' (2,44 m)de
estbndar de |
t8" (457 ram) I
de altura s0breI
la superficie I.
\
7" (178 ram)
19"
I (483 ram)
paracocinar p
305
las
Ajuste
sus medidas
para las diversas
alturas
de techos,
intrados,
gabinetes
o superficies
para
cocinar.
Para
Iograr un funcionamento
adecuado, la parte inferior de
REMATEDETECHO
HUMERO
DECORATJVO
oINTRADOS_
muestran
comunes.
;
,q)
_=
_
REMATE
DEPARED
de la tira de
madera de
montaje
_"
_..
Parte superior
_"
REDONDO
7"(178mm)
t
24" A 30" (009 A 762 mm)
SOBRE EL NIVEL DE LA
SUPERFtCIE
PARA COCINAR
Placa
24"
salpicaduras
para
Series 571
minima
Distancia
entre
la
(opcional)
campana
(610 mm)
f,.%
y
(b
la superficie
CON
1 VENTILADOR
CONDUCTOS
TIPICOS
DE MODELO 51600
para
cocinsr
Superficie
est_ndar de
_
para
_
cocinar
REMATEDETECHO
\
Superficie
para cocinar
de altura
36" (914 mm)
HH0028E
I
DUCTO
REDONDO
(254
mm)
INSTALACION CON UN GABINETE ESTANDAR DE 18" DE I
ALTURA SOBRE LA SUPERFICIE PAPA COCINAR
--
I
HUMERO
DECORATIVO
olNTRADOS_
REMATE
305
DE PARED
Intrados II
_
_'
esandar
de
/|
12"
305mm
12"
-0-Chimenea (305 mm) _
deintrados II
|
13"
Series 5511,
_,(330/ mm)
CAMPANA
/ REDONDA
4/2" x 18-1/2"
10"
t
(1t4
254
x 470
ram)
a
a
24" A 30" (609 a 762 mm)
SOBRE EL NIVEL DE LA
SUPERFICIE
PARA COCINAR
madera de
montaje
CON 2 VENTILADORES
de la tira de
T
EXTERIOR
--
DUCTO
REDONDO
10"(254mm)
|
Placa para
_
salpicaduras
Series 571
(opcional)
I
I
HUMERO
DECORATWO
o INTRADOS
"_"
_"
N
Parte superior
CONDUCTOS TIPICOS DEL MODELO 51200
VENTILADOR
Techo
est_ndar de
8' (2,44 m)
m&xima
entre
la
30"
(762 ram)
CODO
-
Distancia
REDONDO
10" (254 mm)
campana
y
la superficie
_EXTERIOR
PLACA DEL
VENTILADOR
58140
m
Superficie
m
para cocinsr
t
--
Superficie
para cocinar
estandar de
36" (914 mm)
de altura
para
m
cocinar
u
m
HH0027E
24" A 30" (609 a 762 mm)
SOBRE EL NIVEL DE LA
SUPERFICIE
PARA COCtNAR
INSTALACION
CHIMENEA
CON UN INTRADOS
ESTANDAR
DE INTR/_,DOS OPCIONAL
DE
SERIES
12"
551
o
(b
L-"
R"
I CONDUCTOS
EXTERIOR
TIPICOS
MODELO
DEL VENTILADOR
57745
19
1.
Usando un destornillador
Phillips #2 o un Robertson
#2,
destornille
la campana del fondo de la canasta.
Refierase
a la figurar para Iocalizar los 4 tornillos. Tire los tornillos y
quite la campana
de la paleta de madera.
4.
0,
0,
0-
0*
.1
.3
2"
o
o
HR0002
I OPCION
I
Una placa para salpicaduras es disponible (refierse en
p&gina
17 para
mas
informacion).
Este
placa
para
salpicaduras
se debe instalar antes que la campana
debico
a que este cubre los tornillos
de montaje de la placa para
salpicaduras.
Para instalar este placa, asegurese
de tener
18" (457 mm) entre debajo
de la campana
y el panel de
control
de la cocina
o encima
de la cocina.
(Vea las
instructionnes
incluidas
con la placa para salpicaduras.)
2. En la pared, mida y marque una linea de nivel para la tira
de montaje
de madera
(vea las dimensiones
en las
ilustraciones al lado y del paso 2 en pagina 19). Usando los
tomillos
con plana cabeza #10-2"
(incluye
en bolsa de
piezas), asegure
la tira de montaje
a la pared de manera
de alcanzar
los traversaSos
de la pared.
_b
3) 13" (330 ram) o
19" (483 ram) de
techo (yea p&gina 19)
campana,
asegt_rese
de queal lapeso
tira dede
madera
PRECAUCI6N:
Debido
esta
este montada directamente
a todos los
traversaSos
de la pared disponible
(el
entramado de la pared), (un minimo de 2
traversa_os para una campana de 30", m_s por
una mas larga); no s61o a la pared sin refuerzo.
1 1/2"
(38 mm)
HD0068E
1. Pared
2. Tira de madera
3.
4.
5.
6.
20
Tornillos de cabeza plana
Localizacion
de las anclas
Atras de la pared
TraversaSos
de la pared
1.Parainstalar
lacampana
ensulugar,
Uselatirademadera
paraapoyar
lacavidad
delapartedeatr&s
delacampana.
PRECAUCION:
Sostenga
que este completamente
de montura.
Encima
(Vista
la campana
haste
enroscado
a la tira
de la campana
en el interior)
por tornillos
Segure la campana a la tira de la montura con los (4)
tornillos #8 - 3/4" (para una campana de 30" o 36" larga)
o (6) tornillos (para una campana de 42" larga) incluidos,
en lugar indicado. Perfora (2) agujeros de 3/16" de largo
en la pared para las anclas de pared en lugar indicado.
Entonces, instale las (2) anclas de la pared y asegure la
campana con los tornillos #8 - 3/4" y las (2) arandellas.
m
m
HD0064
2. Monte la transicion
(si requerida)
en la placa
Consulta
la pagina
17 por los n0meros
disponibles.
Use cinta para ductos
seguras
y hermeticas.
para
que
todas
del ventilador.
de modelos
las juntas
m
m
sean
2
La placa
del ventilador
modelo
51600
se conecta
directamente
al conducto
redondo de 7", sin transici6n.
El ventilador
exterior
modelo
57745
use la placa del
ventilador
modelo
58140 que se conecta
directamente
al
conducto
redondo de 10", sin transicion.
O,
m
HD0049
m
3. Tienda el cable de energia
al sitio de la instalacion.
Por
detalles
referente
a la instalacion
de los ventilador/placa
del ventilador
vea las instrucciones
incluida
con esa
(vendida
separadamente).
Instale la placa de tal forma
que la caja de cableado
este fuera a la derecha,
cuando
ustedes hace frente a la campana.
"S"
N
Si usted seleccione
escape por detras, quite la placa de
detr&s de la campana
y instale
la placa sobre encima.
Asegure
la placa del ventilador
al interior de la campana,
usando
los mismo (4) tuercas.
Si usted seleccione
escape por encima, quite la placa de
encima de la campana
y instale la placa sobre detr&s.
Conecte
el ducto redondo
a la transici6n
o a la placa
ventilador.
Use cinta para ductos
para que todas
juntas sean seguras
y hermeticas.
del
las
HD0063
m
(a
(a
21
,_
1. Retire la cubierta
poner a un lado.
La instalacibn electrica
ADVERTENCIA:
Peligro de
debe
choque
ser hecha
electrico.
por
personal calificado de acuerdo con todos los
codigos
aplicables
y normas.
Antes de
efectuar el empalme, cortar la alimentacion
electrica
del interruptor
y cerrar
con
seguridad
para prevenir una alimentacion
accidental.
del cableado
de lal place
del ventilador
2. Abra el agujero ciego en la caja de cableado
de la placa
del
ventilador.
Mientras
instale
la placa del ventilador,
tienda 6" del cable de energia y conecte el cable a la caja
de cableado
usando el conector
adecuado.
3. Conecte
el cable NEGRO
al NEGRO,
el BLANCO
al
BLANCO y el VERDE o descubierto
a el tomillo VERDE que
toma de tierra. Vuelva a colocar la cubierta del cableado.
INTER. LAMPARA
TERMOGENA
120V60Hz
ENCHUFE_,
NEMA
5-15P
V_.
N
/
HAClA
MOTOR
[
DERECHA
TERMOSTATO
H!:_
CASQUILLO
LAMP.
I_TER_TILADOR
B
N
_
_
CONTRO
BOASQUILLOBOMBILLADEREOHA
N
VELOC+DAD
_
f-
I
N
DELUZ
I
N
_
B
/
/:ASOUILLOBOMBOE
+N; / ASOU+L'-OBOM°.,Z
INTER. LAMP.
TERM. IZQ
N
O
B
i
I OPCION
I
Una chimenea
de intrados
es dispanible
conductos
si la campana
no es instalada
gabinete.
Vea la instrucciones
incluidas
con
de intrados
opcional.
I
Refierse
en p_gina
17 para informaci6n
1. Para instalar el ventilador,
vea las
con el ventilador.
Una vez que el
conecte
el ventilador
y el cable
enchufe al interior de la campana.
cablos juntos.
sobre
para ocultar
debajo
un
la chimenea
pedido.
]
instrucciones
incluidas
ventilador
este instale,
de la caja electrica
al
NO CONECTE
los dos
Refierse en p_gina 17 para informaci6n sobre el
ventilador/placa
del ventilador
2. Instale
(2) bombillas
termogenas.
Usar bombillas
tamaSo
BR40,
250W
Max.,
infrarroja
solamente
incluydo).
Instale
(3) bombillas
halogenas.
Usar bombillas
tamaSo PAR20 50W (no incluydo).
de
(no
HE0003
de
1
Vea la p_gina 16 para informaci6n
sobre bombillas.
Refierse a la t_ltima p&gina para informaci6n
sobre pedido.
I
J
22
y
PRECAUCION:
Antes de
peliculas
de plastico
sobre
la instalaci6n,
los filtros.
Es recomandable
de instalar los filtros
de terminar con el filtro del centro.
1) Insertar la parte superior
del filtro
de la palangana).
2) Acer girar la parte inferior hacia el
3) Instale el filtro debajo el ataredo y
4) Empleando
la palangana,
resbale
de retenido
interior.
de lado
sacar
en primer
en la campana
las
y
(al lado
m
interior de la campana.
tire.
el filtro debajo la pieza
m
m
m
2
O,
HD0065
m
m
r_
"6"
HD0024
N
Filtros de sustituci6n
son disponibles.
a la _ltima p_gina para informaci6n
sobre
Refierse
I OPCION
I
pedido.
I
l
Filtrosde zig zag son disponibles.Para pedirlos,refierse
a el dibujo debajo para encontar el numero del equipo
correcto
para su campana.
Para instalardos,
refierse
a la
hoja de instalacion
que se encuentran
incluida con los
filtros a zig zag.
I Refierse
en p_gina
EQUIPO
50030
50036
50042
#
17 para informaci6n
LARGO
sobre
pedido.
II
DE CAMPANA
30"
36"
42"
m
N
F,"
23
I
17
\
18
15
HLO031
CLAVENC
1
2
3
4
5
6
PIEZA NO.
V05529
V02264
V02773
V02772
V03435
V03436
V02563
V03502
V03503
10
11
12
13
14
15
V03504
V03501
V03505
V03517
V03519
V03520
V00673
V02512
V01869
DESCRIPCI()N
Logotipo Kenmore Elite
Casquete de porcelana
Conectador macho por motor
Conectador hemera pot motor
Termostato
Soporte por termostato
Interruptor simple SPST para
lampara term6gena
Interruptor doble SPST para
lampara hal_x:jena
Interruptor simple illuminado SPST
para ventilador
Bot6n control de velocidad
Control de velocidad
Terminal de conexion
Cable de alimentaci6n
Cable de control
Cable de interruptor iluminado
Tuerca dentellada 8-32
Tornillo mecanico 8-32 x ½
Tornillo mecanico 6-32 x %
CLAVE NO PIEZANO.
16
V01582
17
V05522
V05523
V05524
18
19
20
21
22
V14763
V14764
V14765
V05528
V05521
V14744
V14745
V05526
V12971
V02544
DESCRIPClON
Tuerca dentellada 6-32
Filto a rejacuba
9.5x 15.25x 0.355
campana 30" (3 requeredos)
Fireoarejacuadrada 11.61x 15.25x0.355
campana 36" (3 requeredos)
Htroa_acuadrada 13.61xl 525x0.355
campana 42" (3 requeredos)
Canal 30"
Canal 36"
Canal 42"
Grapa de filtro 5.265" x 0.350"
Banda sellara 20.625"
Pared interior izquierda
Pared interior derecha
Manual de instaladon por Kanmore Elite
Bolsa de instalaci6n (torn. con plana
cabeza#10xZ'(4), tom. #8x3/4" (8),
Tuercas #10-32 (4), Anclas de la
pared (2),Arandallas 3/16" ID x3/4" OD)
Bombilla hal6gena PAR20 50W
Bombillaterm6gena BR40, 250W max.
Pida piezas de repuesto dando como referencia
PIEZA- no el No. DE CLAVE.
* Herraje estandar - c6mprela
** No se muestra.
a un distribuidor
el No. DE
local.