Download Kenmore Elite 30'' Professional Style Range Hood Shell 51303 Installation Guide
Transcript
L ! T E ,,® Range Hood Use & Care / Installation Manual Campana de cocina Manual de uso y cuidado / instalaci6n Models Modelos 233.51303200 (30" wide - Stainless) 233.51363200 (36" wide - Stainless) 233.51423200 (42" wide - Stainless) w- Z_ O HBO027 ,_ INTENDED FOR DOMESTIC COOKING ONLY,_ _1, CONCEBIDO SOLO PARA USO DOMC:STICO ,_ V05526 rev.D Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com if within 1 year from the date of instaflation, any part of this range hood fails to function properly due to a defect in material or workmanship, Sears will repair the part or furnish and install a new part, free of charge. FULL 30-DAY WARRANTY ON FINISH ON PAINTED OR BRIGHT METAL PARTS if within 30 days from the date of installation, the finish on any painted or bright metal parts of this range hood is defective in material or workmanship, Sears will furnish and install a new part, free of charge. WARRANTY SERVICE iS AVAILABLE BY CONTACTING TH E NEAREST SEARS SEVtCE CENTER/DEPARTMENT IN THE UNITED STATES. This warranty applies only while this product is in use in the United States. This warranty gives you specific legal rights and you may have other rights which vary from state to state. Sears, Roebuck tL 60179 WARNING A WARNING A TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. if you have questions, contact the manufacturer at the address listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. InstaIlation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Do not use this range hood with any additional solid state speed control device. 7. Ducted fans must always be vented to the outdoors. 8. To reduce the risk of fire, use only steel ductwork. 9. This unit must be grounded. TO REDUCE THE RiSK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spilIovers that may ignite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods. 3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware for the size of the surface element. appropriate A and Co., Dept 817WA, Boffman Estates, A TO REDUCE THE RiSK OF iNJURY TO PERSONS iN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. if the flames do not go out immediately, EVACUATE AND CALL THE FiRE DEPARTMENT. 2. NEVER PiCK UPA FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - This could cause a violent steam explosion. 4. Use an extinguisher ONLY if: A You know you have a Class ABC extinguisher and you already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on "Kitchen Fire Safety Tips" published by NFPA. CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,construction dust, etc. off power unit. 3. Your hood motor has a thermal overload which wiI! automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. if the motor continues to shut off and restart, have the hood serviced. 4. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. 5. To reduce the risk of fire and to properly exhaust air on a ducted installation, be sure to duct air outside - Do not exhaust air into spaces within walls or ceiling or into attics,crawl spaces, or garage. 6. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switch on accidentally, switch power off at service panel and lock or tag service panel. 7. To reduce the risk of fire and electric shock, the Kenmore ELITE 51000 Series hood must be installed with blower models 51200, 51600, or 57745 only. Other blowers cannot be substituted. (Blowers sold separately). 8. Use with approved cord-connection kit only. 9. Please read specification label on product for further information and requirements. Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. will help keep the whole kitchen cleaner and brighter. = This O 4-EB I 3 Warming lamps lamp switches lights filters The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe. Wash more often grease - like frying 4. Halogen light switches 5. ON/OFF Blower switch 6. Blower speed control Lamps (Infrared) if your cooking style foods or wok cooking. Remove filters by pushing filters and rotating filters downward. Blower HCOO04K 1. Warming 2. Warming 3. Halogen Grease generates towards the back greater of hood Cleaning Remove the grease filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Refer to blower instruction manual for more details. Grease Rail The grease rail baffle filters are grease rail from See illustration should be cleaned frequently, especially if used. Remove filters, then, disassemble the the hood by removing its 3 retaining screws. below. Each warming lamp (item 1 on picture above) is controlled with is own ON/OFF switch (item 2 on picture above). Use only BR40 Size, 250W Max., Infrared bulbs. (Purchase separately.) _._ ARNING:on warming Do not material Cooktop Lighting place shelves.highly flammable (Halogen) A double set of ON/OFF switches (item 4 on picture control the halogen lights (item 3 on picture above). The front rocker controls controls both side lights. best cooktop lighting. the center Select one, above) light. The rear rocker two, or three lights for Use PAR 20, 50W halogen bulbs. (Purchase Please refer to page 4 for ordering information.) separately. is operated using /% _ / ,/ HD0069 / "_ Refer to Stainless steel cleaning in Hood Cleaning section below. Once the grease rail is clean and dry, reassemble it to the hood and reinstall filters. Blower The blower o two (2) controls. Use the ON/OFF blower switch (item 5 on picture above) to start and stop the blower. When turned on, the blower will operate at the previous setting of the speed control (item 6 on the picture above). Hood Turn the speed control speed - counterclockwise - Regularly wash surfaces with clean cloth or rag soaked warm water and mild soap or liquid dish detergent. knob clockwise to decrease to increase speed. blower Cleaning Stainless steel cleaninq: How to maintain its "BRIGHT LOOK" Do: with HEAT SENTR_ - Always Your hood is equipped with a HEAT SENTR_ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface. - Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. 1) If blower is OFF 2) If blower to HIGH is ON at a lower speed. When return - it turns the temperature level to its original setting. blower speed drops ON to high speed. setting - it turns to normal, blower the blower up will clean in the diredtion - You may also use a specialized WARNING: The HEAT SENTRY thermostatcan start the blower even if the hood TM is turned OFF. When this occurs, it is impossible to turn the blower OFF with the switch. If you must stop the blower, do it from the main electrical panel. polish household lines. stainless steel cleaner. Don't: _" - Do not use any steel scrapers to remove - Do not allow or stainless stubborn - Do not use any harsh ,_ of original stell wool or any other dirt. or abrasive cleaners. dirt to accumulate. - Do not let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface. Avoid: when choosing that contains -Any products containing: surfaces - Any combustible acetone, alcohol, and should 3 -- a detergent - Any cleaners will deteriorate -- bleach chloride, will attack fluoride, stainless iodide, steel. bromide _, such as explosive _1 rapidly. products used for cleaning ether, benzol, etc., are highly not be used close to a range. _, m _ Wood mounting PAR 20 50W Light Bulb (3 per hood) Sears Part No. 57853 strip Grease Filter (3 per hood) Parts Bag (includes 4 fiat head screws #10-2", 8 screws #8-3/4", 4 Nuts #10-32, 2 Wall anchors and 2 Washers 3/16" Warming Lamp BR40, 250W Max. (2 per hood) (_ Ducting Accessories (See "51000 Series Range Hood Ducting Accessory Model Nos.) (interior 5 for System" on page 5 for OR exterior) (See "51000 Series Blower Model Nos.) J / Q Screwdriver Drill on page ID x 3/4" OD) Blower (Robertson System" or Phillips) Pencil Sabre Saw -or- Keyhole Saw Tape Measure Range Hood / 3/8" Nutdriver Wire Duct Tape Stripper F Wall & Roof Caps, Exterior Blower L Sears Stock Number 57745 Broan Model 437 1200 cfm Exterior Blower High Roof I Broan Model 441 10" Round Wall Cap Capacity Cap Broan Model 647 7" Round Wall Cap \ i © --© Adjustable Cap i F Broan Model 10" Round Roof / I I Elbows and In-Line Dampers L Sears Stock Number 59091 418 Broan Model 7" Round Broan Model 421 10" Round Vertical Elbow /In-Line Adjustable Damper o_ 415 Elbow / F L m i Ductwork 2 Broan Model 410 10" Round Duct Broan Model 407 7" Round Duct (2 ft. sections) (2 ft. sections) I I F Choose 1 of 5 Discharge Transitions _ 1 m ( i I (b Broan I Broan I Model 427 (4½"x18½" i tol0"Rd., 6" high - lateral) Model 423 (4 ½" x 18 ½" to 10"Rd., -vertical) I \ Broan Model 424 Broan Model 454 Broan Model (4 ½" x 18 ½" tol0"Rd.,Horiz, (4 ½" x 18 ½" tol0"Rd.,Horiz, (4 ½" x 18 ½" tol0"Rd.,Horiz. front - rear) Horiz. / right) Horiz. / left) 453 L \ i i i i \ \ \ mSears Sto_ Number 58140 Optional Soffit Chimney _ __ Rough-in Kit (Use with Exterior Blower Model 57745) // (30") (36") Stock Numbe_ (42") // f- -_ J rs Stock _ "_ Number 51600 Blower/ / Rough-in Kit (600 cfm Interior Blower and _ _JJ_J Rough-in Choose 1 of 3 Blower Systems L 55130 55136 Sears 55142 51000 Sears Stock Number 51200 Blower / Rough-in Kit (1200 cfm Interior Blower and Rough-in Plate) SEARS STOCK NUMBERS available through your local Sears store, on line at Sears.com, or from Sears Parts at 1-800-366-7278. For availability of Broan Models, pease ca 1-800-558-1711. (Canopy controls Series Plate) Hood with blower _ & lighting. _-._ Required for all installations.) Optional Baffle Filters _ Optional Backsplash Sears Stock Number 57130 (30"), 57136 (36"), 57142 (Stainless steel wall covering with warming shelves.) O_ Sears Stock Number 50030 50036 50042 (30") (36") (42") HL0032 (42") Cb Kenmore rangehoodsaredesigned toperform efficiently whenattached tolongrunsofduct.Asa pointofreference, thishood willfunction atapproximately 80%ofitsratedairperformance when100equivalent feetof7"roundductwork isattached (for 600cfmblowers) or 125equivalent feetof10"roundductis attached (for1200cfmblowers). Usethischarttocalculate the equivalent ductlengthofyoursystem. Notethat7"roundistheminimum recommended ductsizefor600cfmblowers, and10" roundistheminimum recommended ductsizefor1200cfmblowers. Broan Model 424 4 V2-in. x 18 1A-in. to 10-in. Round - Horiz. Broan Model 407 Straight Duct 7-in. round x 2-ft. long Equivalent length 7-in. Round Front / Rear Transition Equivalent length Wall Cap Equivalent Broan Modellength 647 10ft. 30 ft. (15-ft. w/o damper) 2ft. Broan Model 454 4 V2-in. x 18 1A-in. to 10-in. Round - Horiz. Right Transition Equivalent length Broan Model 410 12ft. Straight Duct 10-in. round x 2-ft. long Equivalent length 2ft. 40 ft. (25-ft. wio damper) Broan Model 441 10-in. Round Broan Model 453 41A-in. x 18 Y2-in. to 10-in. Round - Horiz. Left Transition Equivalent 7-in. Round Elbow Broan Modellength 415 Equivalent Broan Model 437 10-in. Round Roof Cap _uivalent length length Wall Cap Equivalent length 40 ft. (25-ft. w/o damper) 12ft. 8ft. 10-in. Round Elbow Broan Model 418 Equivalent length 10ft. Sears Model 59091 Roof Cap (7-in. round) Equivalent length 30 ft, (7-ft. w/o damper) Broan Model 427 4 4/2-in. x 18 'A-in. to 10-in. Round, 6-in. High - Lateral Transition Equivalent length 2ft. Broan Model 423 41A-in. x 181A-in. to 10-in. Round - Vertical Transition Equivalent 2ft. length EARS STOCK NUMBERS available through your Ioca_ ears store, on line at Sears.com, or from Sears Parts at I 1-800-366-7278. For availability of Broan Models, I please call 1-800-558-1711. I 1. The Kenmore Elite Series hood must be installed with interior blower models 51200 or 51600, or exterior blower 57745 only. Other blowers cannot be substituted. (Blowers sold separately.) Plan where and how the ductwork Install proper-sized ductwork, roof or wall cap for the model For best results, and elbows. transition(s), elbow(s), and of blower you are using. use a minimum ROOF will be located. number Dimensions below. for the most common are shown Adjust your measurements for various heights of ceilings, soffits, cabinets or cooktops. For proper operation, the hood must be a minimum of 24" and a maximum of 30" above the cooktop. Standard 8 ft. (2.44 m) ceiling of transition 19" O_ Top of wood mounting strip WALL CAP (305 _ H°°d X HOOD m ROUND ELBOW m t 571 Series Backsplash (optional) 24" TO 30" (609 to 782 mm) ABOVE COOKING SURFACE HH0_24A MODEL 51600 SINGLE BLOWER TYPICAL DUCTWORK ROOF 24" (610 ram) I Minimum distance between the hood and _l_ I the cooktop Cooktop 10" (254 ram) ROUND DUCT H cooktop HHOO28A INSTALLATION WITH STANDARD 18" HIGH OVER-COOKTOP CABINET DECORATIVE WALL CAP m m C3 (305 4-1/2" x 18-1/2" to 10" (114 x470to ROUND HOOD O = -- Standard 36" (914 mm) CAP \ FLUE or SOFFIT m (483 mm) DECORATIVE I m CAP 7" (I78 ram) ROUND DUCT FLUE or SOFFIT installations Standard 8 ft. (2,44 m) ceiling Standard 12"(305ram) soffit 13" t 24" TO 30" (606 ABOVE COOKING (33mm)O to 762 i'qrn) SURFACE MODEL 51200 DUAL BLOWER TYPICAL DUCTWORK EXTERIOR | Hood ] X Top of wood mounting strip BLOWER -- 10"(254mm) ROUNDDUCT l 571 Series I _ Backsplash optional) DECORATIVE FLUE or SOFFIT 30" (762 mm) 10" (254 ram) (305 EXTERIOR ) BLOWER Maximum distance between the hood and the cooktop 58140 HOOD ROUGH-IN _ Cooktop KIT t Standard 36" (914 mm) H cooktop HHOO27A INSTALLATION WITH 12" SOFFIT OR OPTIONAL SOFFIT CHIMNEY 551 SERIES 24" TO 30" (609 to 762 mm) ABOVE COOKING SURFACE MODEL 57745 EXTERIOR BLOWER TYPICAL DUCTWORK -- / J (b 1. Using a Phillips #2 or a Robertson #2 screwdriver, unscrew the hood from the bottom of crate. Refer to figure to the right to locate all 4 screws. Discard these screws and remove hood from wood pallet. 4. 0, O_ Oo O_ .1 2 • o o HR0002 I OPTION I A Backsplash is available (see page 5 for more details). This backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18" (457 mm) clearance between bottom of hood and range control panel or cooktop. (Refer to instructions included with backsplash.) 2. Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustrations to the right and under step 2 on page 7). Use #10-2" flat head screws (included in the parts bag) to secure the mountto the drywall. Make sure to hit the wall studs. CAUTION: Due to the weight of this hood, ensure that the wood strip is attached to all of the available wall studs (2 studs minimum for the 30" hood, more as hood width increases); not into drywall alone. t3" (330 ram) or 19" (483 ram) from ceiling see page 7 (38 mm) HD0068A 1. 2. 3. 4. 5. 6. Drywall Wood Mounting Strip Flat Head Screw Wall Anchor Location Outline of the Back of the Hood Wall Studs 1.Restthebackcavityofthehoodonthewoodmounting strip. 4_5 CAUTION: secured Hold the to the wood Top of hood (inside view) until it is completely mounting strip. hood Mounting Secure hood to wood strip with (4) screws #8 - 3/4" (for 30" and 36" width hoods) or (6) screws (for 42" width hood) provided at location shown. Drill (2) 3/16" size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then install screw locations m m the (2) wall anchors and attach the hood to these anchors with the remaining #8 - 3/4" screws and the (2) washers provided. O} HD0064 2. Attach Refer transition (if required) to blower rough-in to page 5 for available model numbers. Use duct tape to make all joints secure and plate. m air-tight. m Model 51600 blower plate connects directly to 7" round duct without a transition. Exterior blower model 57745 utilizes a model 58140 mounting plate which connects directly to 10" round ductwork without a transition. HD0049 m m 3. Run power cable to installation location. Refer to the instructions included with the selected blower / rough-in kit (sold separately) for details on installing the rough-in plate, install the rough-in plate so that the wiring box is located on the right side as you are facing the hood. t3 For ducting through back of hood, remove existing plate from inside back of hood and attach to inside top of hood to cover hole. Secure to threaded studs with same (4) nuts. For ducting through top of hood, place on inside back of hood. existing Connect ducting to transition or rough-in installing the rough-in plate. Use duct joints secure and air-tight. plate remains in plate as you are tape to make all HD0063 O} 9 m 1. Remove _i wiring mustRisk WARNING: be done of electrical by qualified shock. personnel Electrical in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. wiring cover from S_o 3. Connect BLACK to BLACK, or bare wire under GREEN cover. FAN MOTOR RIGHT HEAT LAMP SOCKET NEMA _15PPLUG % THE HS RMOST_T _B W R,GHTL,GHT W SOCKET L:NT_CCKE] °Ow B LEFT LIGHT SOCKET LAMP SWITCH "___ i W[ HE0018 I OPTION w W I I A Soffit Chimney is available - to hide ductwork if the hood is not installed under a cabinet. Refer to the instructions included with the soffit chimney. Refer to page 5 for ordering I information. J1 1. To install blower, refer to instructions included with blower / rough-in kit. Once the blower is installed, plug the blower unit into the female receptacle and the power supply onto the male connector inside the hood. DO NOT plug the two cords into each other. I See page 5 for blower / rough-in kit information. ] HE0003 2. Install (2) heat lamp bulbs. Use BR40 size, 250W Max., infrared bulbs only (purchase separately). Install (3) halogen light bulbs. Use PAR20 50W size (purchase separately). See page 4for bulb information. Refer to page 12 for ordering information. 10 plate and set aside. 2. Remove appropriate knock-out from rough-in plate. As you are installing the rough-in plate, feed 6" of power cable through knock-out opening and attach cable to wiring box with appropriate connector. RIGHT HEAT LAMP SWITCH 120V 60Hz IN rough-in WHITE ground to WHITE and GREEN screw. Reinstall wiring _ AUTION: filters beforeRemove installingprotective them. plastic film covering It is recommended to install side filters first and finish with center one. 1) insert upper end of filter into the hood (finger sized cup side). 2) Raise lower end toward the inside of hood. 3) Position rear part of filter into channel and pull. 4) Using finger sized cup, pull on the upper end of filter and slide it under the front inner retaining piece. m m O_ m m 2 HD0065 m m 13 HD0024 I Refer I OPTION Replacement filters are available. to page 12 for ordering information. I I I Baffle filters are available. To order them, refer to the table below to find the right filter kit number for your hood. to install them, refer to instuction sheet included with baffle filter kit. I Referto KIT # 50030 50036 50042 page 5fororderinginformation. I HOOD WIDTH 30" 36" 42" O_ 11 m 0 20 I 17 \ 18 HL0031 KEYNO, 1 2 3 4 5 6 7 PARTNO. V05529 V02264 V02773 V02772 V03435 V03436 V02563 V03502 V03503 10 11 12 13 14 15 V03504 V03501 V03505 V03517 V03519 V03520 V00673 V02512 V01869 KEYNO, 16 17 DESCRIPTION Kenmore Elite Logo Porcelain Lamp Socket Male Motor Connector Female Motor Connector Thermostat Thermostat Bracket SPST Single Switch for Heat Lamps SPST Double Switch for Halogen Lights SPST Lighted Single Switch for Blower PARTNO. V01582 V05522 V05523 V05524 18 19 2O 21 22 Speed Control Button Speed Control Terminal Block Power Cord Control Wire Lighted Switch Wire Lock Nut 8-32 Machine Screw 8-32 x t½ Quadrex Machine Screw 6-32 x _/4Pan Quadrex ** * V14763 V14764 V14765 V05528 V05521 V14744 V14745 V05526 V12971 V02544 Order replacement DESCRIPTION Lock Nut 6-32 Sq. Perf. Grille Filter for 30" Hood 9.5 x 15.25 x 0.355 (3 required) Sq. Perf. Grille Filter for 36" Hood 11.61 x 15.25 x 0.355 (3 required) Sq. Perf. Grille Filter for 42" Hood 13.61 x 15.25 x 0.355 (3 required) Grease Rail 30" Grease Rail 36" Grease Rail 42" Filter Spring 5.265" x 0.350" Sealing Extrusion 20.625" Left Side Liner Right Side Liner Manual for Kenmore Elite Installation Bag (Flat head screws #10 x 2" (4), Screws #8 x 3/4" (8), Nuts #10-32 (4), Wall anchors (2), Washers 3/16" I D x 3/4" OD) Halogen Lamp PAR20 50W Heat Lamp BR40, 250W max. parts by PART NO. - not by KEY NO. * Standard hardware - may be purchased ** Not illustrated. 12 locally. Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! ::::::::::::::_ iiiiiiiiiiiiiiiii For the replacement parts, accessories and owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters. '_ ::::::::::::::_ HHHHHHHHi i 1-800-4-MY-HOME Call anytime, ® (1-800-469-4663) day or night (U.S.A. and Canada) www.,ear,.com www.,ear,.ca Our Home =_ iiiiiiiiiiiiiii iiiiiiiiiiiiiiiii For repair of carry-in items like vacuums, lawn equipment, and electronics, call or go on-line for the location of your nearest -- Sears Parts & Repair Center. 1-800-488-1222 Call anytime, day or night (U.S.A. only) w_,,.,ears.com To1:urchase pr°tecti°n800 827 t 6655 (U.S.A.)agreement ,,,,,,,,,,,,,,, _" on prod.uctl 1 800 361serviced6665 (Canada)bY Sears: __-u_ Para pedir servicio a domicilio, de reparaciOn y pare ordenar Au Canada pour service en fran(_ais: _" 1.800.LE.FOYERMC piezas: 1"888"SU'HOGARSM (1-800-533-6937) www.sears.ca (1-888-784-6427) ,,,,,,,,,,,,,,, o" := i TM ® Registered Trademark / Trademark / SMService Mark of Sears, Roebuck and Co. ® Marca Registrada / TM Marca de Fabrica / SM Marca de Servicio de Sears, Roebuck and Co. MC Marque de commerce / MD Marque deposee de Sears, Roebuck and Co. 13 ® Sears, Roebuck and Co. SECCI6N PAGJNA Si dentro de 1 abe de Ia fecha de la instalaci6n, cuaJquier parte de esta campana de cocina deja de funcionar en forma Garantia................................................................................. 14 apropiada debido a defecto en ei material o la mane de obra, hstruccionesde seguridad.................................................. 14 Sears repararA Ia pieza afectada o proveerA e instalara una ©peraci6n .............................................................................. 15 pieza nueva libre de cargo. GARANTIA COMPLETA DE 30 BiAS EN EL ACABADO EN Limpieza ................................................................................ I5 PJEZAS MET.,_LICAS PJNTADAS O ABRILLANTADAS Piezas incluidas .................................................................... 16 Piezas non incbidas ............................................................. Herramientas necesanas ..................................................... 16 16 Sistema de ia campana Serie 51000 ................................... Cuadro de equivalencia de largo de conducto ................... Prepare Ia Iocalizaci6n para la campana ............................ Prepare la campana ............................................................. Instab la campana ................................................................ Conecte et cabIeado ............................................................. 17 18 19 20 21 22 Si dentro de 30 dias de la fecha de Ia instalacidn, el acabado de cualquier parte metAlica pintada o abrillantada perteneciente a esta campana de cocina aparece con defecto en el material o la mano de obra, Sears proveerA e instalarb, una pieza nueva libre de cargo. EL SERVICIO DE GARANTIA SE OBTJENE PONtg:NDOSE EN CONTACTO CON EL CENTRO DE SERVICJO O DEPARTAMENTO SEARS M.,_SCERCANO EN LOS ESTADOS UNIDOS. Esquema eI6ctrico ................................................................ Terminar Ia instalaci6n .......................................................... Instab los filtros .................................................................... Piezas de servicio ................................................................. 22 22 23 24 Esta garantia es vaiedera unicamente si este producto se tiene en uso dentro de los Estados UnJdos, Esta garantia le confiere derechos Iegales especificos y Ud. puede tener ademb, s otros derechos que vadan de estado a estado. Sears, Roebuck and Co., Dept. 817WA, Noffman Estates, IL 60179 ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RmESGO DE INCENDtO, CROQUE ELECTRmCO, O LESION A PERSONAS, PROCURE LO SIGUIENTE: 1. Utilice esta unidad s61o en ia manera prescrita pot el fabricante. Si fiene usted alguna pregunta, comuniquese con el fabricante a la direcci6n indicados en la garantia. 2. Antes de efectuar aigOn servicio o iimpieza, se debe desconectar la corriente electrica en el armario de circuitos y asegurarlo con IIave para evitar que ta corriente sea conectada accidentalmente. Cuando el dispositivo para desconectar ei servicio electrico no puede ser cerrado con algQn tipo de traba, sujete fuertemente al panei de servicio, una etiqueta de advertencia prominente. 3. Todo trabaio de instaIaci6n y cableado eiectrico debe ser reaJizado por personal calificado y de acuerdo con todos los c6digos y normas pertinentes, incluyendo los c6digos y normas reiacionados con construcci6n clasificada para incendio. 4. Aire suficiente es necesario para facilitar Ia combusti6n adecuada y la salida apropiada de gases por Ia chimenea de Ia unidad y para evitar corrientes de aire invertidas. Siga las instrucciones y medidas de seguridad deI fabricante dei equipo y ios publicados por la Asociael6n nacionaI de protecci6n contra incendidos (NFPA pot sus siglas in Ingles), y la Sociedad americana de ingenieros de calefacel6n, refrigeraci6n y aire acondielonado (ASHRAE por sus siglas in Inglg, s), y los reglamentos de seguridad locales. 5. Acortaroperforariaparedoeltecho, noda_eelcableadoei6ctrico ni otros servicios pObticos ocuitos a la vista. 6. No utilice este ventilador con ningQn dispositivo de una control de veloeldad de estado s6iido adicionaL 7. Los abanicos con ducto deber_Snsiempre tener una salida hacia el exterbr. 8. Para reduelr el riesgo de incendio, use s61o ductos de metal 9. Esta unidad se debe instalar con tierra efectiva. PARA REDUCIR ELRIESGO DE INCENDIO DE GRASA EN LASUPERFICIE DE LA ESTUFA: 1. Nodejenuncalosaparatosdecocersin vigilenciaafuegovivo. Los desbordamientos producen humo y derrames grasiendos que pueden inflamarse. Caliente e! aceite despacio, a fuego lento o mediano. 2. Ponga en marcha siempre la campana al cocinar a temperaturas elevadas o aI cocinar alimentos flameados. 3. Limpieconfrecuencialosventiladores. Nodebepermitirquelagrasa se acumule en el ventilador ni en el filtro. 4. Utilice un sart6n de tama_o adecuado. Siempre adecuado aI tamaBo del elemento de superficie. utilice el utensilio _ _, PARA EVITAR RESGO DE LESIONES PERSONALES EN CASO DE INCENDIO DE GRASA EN LASUPERFICE DE LA ESTUFA, OBSERVE LO SIGUIENTE:* 1. Cubra y sofoque las ilamas con una tapa aiustada, azafate de hornear gailetas, o azafate de metal, y luego apague el calentador. TENGA CUIDADO PARA EVITAR QUEMADURAS. Si tas llamas no se apagan inmediatamente, HAY QUE EVACUAR Y LLAMAR LOS BOMBEROS. 2. NUNCAALCE UNASARTf_N QUETENGALLAMAS -Usted se puedequems_se. 3. NOUTILICEAGUA, incluyendotrapos, lavaplatos mojadosotoatlas_ puede que occuran explosiones de vapor vioIentas. 4. Utiibe un extinguidor SOLAMENTE si: A. Usted sabe que tiene un extinguidor de clas ABC y !o sabe utiIizar. B. El incendio es peque_o y contenido dentro det area donde se inici6. Q Los bomberos han eldo avisados. D. Usted puede combatJr e! incendio con una salida a su espalda. * Basado en tas recomendaciones para "Seguridad en la Cocina" pubticadas pot la NFPA de Ios EEUU. PRECAUCION I. S61o para uso de ventilaci6n general.No se use para extramateriales o vapores peligrososo explosivos. 2. Para evitardaBos alcojinentedeJ motor y/o impulsores ruidososo desequilibrados,mantenga lafuentede potencialejosde roeiosde pared seca, de polvode construeci6n, etc. 3. Elmotor delacampana tieneun dispositivo contrasobreeargast6rmicas que apaga elmotor en forma automatica si@ste se sobrecalientaEl motor volver&arrancarcuando se enfrie. Sielmotor sigueapagandose, haga verificar Ia campana. 4. Para !ograr una mejor captura de las impurezas producidas al coelnar, la parte inferior de la campana deber_ estar a un minimo de 24" y un m_4ximo de 30" sobre el nivet Ia superficie para cocinar. 5. A fin de reducir los riesgos de incendJo y para bien evacuar el aire de salida, &seg{Srese de evacuar el aire elexterior _No evacue el aire en espasies lim_dos c_omoel intedor de la paredes o deltecho e en el desvb_n,falso techo o garaje. 6. Este producto esta equipado de un termostato que puede hacer partir et ventitador automaticamente. Para evitar los riesgo de da_o, apague ta corrbnte de panel el6ctrico y elerre con candado o afiche una adver[anela en et panel para prevenir que la campana funcione automaticamente. 7. Para reducir et riesgo de incendio y descarga electrica, este campana Kenmore Elite Series 51000 debe ser instabda con ventiladores modebs 51200, 51600 o 57745 solamente. Otros ventiladores no debe ser utilisado. (Ventiladores vendidos separadamente.) 8. Utilice s61o con un conjunto autorizado de conexi6n con cord6n. 9. Por favor, Iea la etiqueta de espeelficaciones en el producto para mayor 14 informaci6n y requisito. Siempre hacerfuncionar lacampana antesdecomenzar a cocinar afindeestablacer unacirculaci6n deaireenlacocina. Dejeigualmente funcionarla campana algunosminutos despues dequeparedecocinar afindelimpiar elaire.Esto ayudaa concervar lacocinamaslimpiay unairepuro. O 4-E" = para grasa Limpie frecuentemente los detergente suave. Los filtros I Limpie mas seguido si su comida crea fritura o preparar la comida con wok. Limpieza agua lavar caliente y un en lavaplatos. mucho grasa - come del ventilador Quitar los filtros para grasa a fin de que tener acceso al ventilador. Pasar la aspiradora en el ventilador por limpiar. No permita la entrada de agua en el ventilador. Para m&s informacion, refierse a el manual del ventilador. 2 HCOOO4K 1. Lamparas tormogenas Interruptores de lamparas termogenas Luces hal6genas Interruptor de luces halogenas Interruptor de encender/apagar del Control de velocidad del ventilador filtros con se pueden Empuje los filtros hacia el interior de la campana y leberelos del canal para queen seguida los retire de la campana. 3 2. 3. 4. 5. 6. Filtros Canal Limpie frecuentemente el canal, sobre todo si utilice los filtros de zig zag. Quite los filtros, despues dejunta el canal de la campana en quita los 3 tornillos. Ver dibujo de abajo. ventilador L_mparas termog_nas: Cada I&mpara es controlada independientemente con su propio interruptor. Utilice las bombillas infrarrojas (BR40, 250W max.) t, _,_ No dejar materias enDVERTENClA: los estantes que calientan. Luces hal6genas: Los dos interruptores controlan las luces hal6genas. t, inflamables de encender/apagar El interruptore a bascula antes, controla la luz del centro. El interruptor detras controla las luces de cada lado. Encenda una, dos o tres luces segQn su necesidad. Utilice las bombillas de halogenas PAR 20, 50W (comprar separadamente; refierse a la p&gina 4 para informacion sobre pedido). Ventilador: El ventilador Utilice el interruptor encender y apagar ventilador funciona funciona / / ,/ /' con la ayuda de dos controles. endender!apagar tiene una luz roja para el ventilador. Cuando est& en tension, el a la velocidad utilizada la 01tima vez. HD0069 l Yea Acero inoxidable en la parte Limpieza de la campana abajo. Una vez que el canal este limpio y seco, instale en la campana y instale los filtros. Utilice el control de velocidad del ventilador girando en el sentido de las agujas del reloj para disminuir la velocidad y en el sentido contrario de las agujas del reloj para augmentar la velocidad. Limpieza HEAT SENTRY "rM - Lavar regulamente la superficie con un trapo o un paso empapado de agua tibia y de jab6n suave o detergente a vajilla. Su campana esta equipida con termostato tiene un mecanismo acelerara el ventilador si se detecta de la cocina. 1) Si el ventilador maxima. esta apagado 2) Si el ventilador esta encendiro se pendera a una velocidad HEAT SENTRY TM. Este que se encender& o un calor excesivo encima - el se pender& a una velocidad Acero de la campana inoxidable: Lo que debe Como minima - el Cuando la temperatura disminuye a un nivel ventilador vuelve a la funcion de origen. normal, el ADVERTENClA: El HEAT SENTRY termostato puede comenzar a funcionar alTM igual si la campana esta parada. Cuando este situacion ocurre, es imposible parar el ventilador con los interruptores. Si usted para la campana, halago a partir del p_nel el_ctrico principal. una "aparencia brillante" - Siempre limpie en el sentido de las lineas originales de pulimento. - Siempre enjuague bien con agua limpia (2 a 3 veces) despues de haber limpiado seque completamente la superficie. - Usted puede especialmente a una velocidad maxima. mantener hacer: Lo que no debe utilizar un limpiador domestico para el acero inoxidable. ta hacer: - No utilice todo otto ninguna raspador - No utilice ningun - No deje hecho lana de acero o de acero inoxidable para quitar la suciedad tenaz. limpiador la suciedad en polvo abrasivo o O, o riguroso. acumularse. - No deje el polvo de yeso o todo otro residuo de construccion que caiga en la campana, cObrala durante el trabajo para asegurarse queen ningQn caso el polvo se pegue a la superficie del acero. A evitar cuando elige u un detergente: - Todos los productos de limpieza que contienen blanqueo; van a deteriorar el acero inoxidable. -Todos los productos o bromuro; estos m agentes de que contienen cloruro, fluoruro, yoduro deteriorans r&pidamente las superficies. ta ta t,a - Todos los productos acetona, alcohol, 15 expl°siv°s combustible 6ter, benzol, Y no deben utilizados para la limpieza: etc...; son extremamente ser utilizados cerca de una cocina. R" 6" Tira Bombillas PAR 20 50W (3 para campana) Sears Pieza No. 57853 de madera ..... Filtros para grasa (3 para campana) BR40, 250W Max. L_mpara termog_na (2 para campana) (_ Accesorios Bolsa de piezas (incluye 4 tornillos #10-2", 8 tornillos #8-3/4", 4 tuercas #10-32, 2 anclas de la pared y 2 arandelas 3/16" ID x 3/4" OD) de conducto (Yea "Sistema de campana 51000 Series" en la p&gina 17 para vear los nQmeros de modelo de accesorio de conducto. Ventilador (interior o exterior) (Yea "Sistema de campana 51000 Series" en la p&gina para vear los nQmeros de modelo del ventilador.) / / Q Detornillador (Robertson Perforadora o Phillips) Cinta m_trica L&piz / Herramienta para apretar tuercas de 3/8" Sierra de Segueta - - o vaiven Cinta adhesiva a conducto 16 Herramienta para quitar la funda 17 63 F Remates de pared o de techo, Ventilador exterior L Nt_mero Sears 57745 Ventilador Exterior 1200 pcm Modelo 437 Broan Modelo 441 Tapa del techo Alto rendimiento I Modelo Broan Tapa del muro 7" Redando \ Tapa del muro 10" Redonda I F Broan 647 Nt_mero Sears 59091 Tapa del techo .j J J m m I Codes y Compuerta de tira J L Modelo Broan 418 Coda ajustada de 10" redanda Modelo Modelo Broan 421 Compuerta de tira en linea vertical de 10" Broan 415 Codo ajustado 7" Redondo de I J v m m F L 2 Conductos Modelo Broan 410 Conducto redondo de 10" Modelo Broan 407 Conducto redondo de 7" (Secciones (Secciones F Elegir 1 de 5 transici6ns r /7 / de 2 pies) I I de 2 pies) T O, m m ¢ I I Modelo Broan 427 Modelo Broan 423 (4 ½" x 18 ½" a Modelo Broan 424 (4 ½" x 18 ½" Modelo Broan (4 ½" x 18 ½" 454 Modelo Broan (4 ½" x 18 ½" I (4 ½" x 18 ½"_ 0" Rd. - vertical) a 10" Rd., Horiz. a 10" Rd. Horiz. a 10" Redanda, i'--.)a10'' 6 a tura Reaenae, - _tera 1' frente Horiz. / derecha Heriz. i izq.) - itr,s ) 453 Hariz. N Chimenea de intr&dos opcional nt_mero Sears 55136 (36") 55142 (42") 55130 130") _ Nt_mero Sears 58140 Placa del ventilador (Utilice exterior con el ventiladar modelo 57745) Elegir 1 de 3 sistemas de ventilador L __._ "--_1_ /_ \ I _ _ \ \ \ Sears, en linea en Sears.com, o per Piezas Sears al disponibilidad par de los modelos J 1-800-366-7278. OMERO SEARS Por sonla disponibles su local tienda de Braan, Ilamar al 1-800-558-1711 per favor. // _J-_Ventilador / Placa o Sears 51600 _ _ del ventilador _ _ _J-_ Nt_mero Sears 51200 Ventilador /Placa del ventilador (Ventilador interior de 1200 pcm y placa del ventilador) J /__ ('_'_) Campana 51000 Series (Pabellon con controles del ventilado y iluminacion. Se requiere para todas las instalaciones.) _ de 600 pcm y placa del ventilador) (Ventilador interior m u Filtros de zigzag Nt_mero Sears 50030 (30") 50036 (36") 50042 (42") Placa salpicadura opcional N_mero Sears 57130 (30"), 57136 (36"), 57142 (42") (Cubierta para pared, de acero inoxidable, con estantes para calentamiento.) 17 HL0032 N F," Las campanas Kenmore son hecho para cumplir un buen rendimiento cuando son junta a conducto largo. Como referencia, este campana funciona aproximadamente con 80% de su prestaciones de aspiracion cuando una equivalencia de 100 pies de conducto redondo de 7" este junto (para un ventilador de 600 pcm) o una equivalencia de 125 pies de conducto redondo de 10" este junto (para un ventilador de 1200 pcm). Empleo este cuadro para calcular la equivalencia de largo de conducto para su sistema. Fijense bien que uno conducto redondo de 7" es el tamaSo minimo por un ventilador de 600 pcm y que uno conducto redondo de 10" es el tamaSo minimo por un ventilador de 1200 pcm. Modelo Modelo Broan 407 Recto conducto 7 pul. Equivalente redondo x 2 pies de largo Equivalente largo Modelo 0 Tapa del muro redondo de 7 pul. Equivalente Modelo Broan largo 647 (_ 30 pies largo (15 pies sin compuerta de tira) 10 pies 2 pies ( Broan 424 4 1Apul. x 18 1Apul. a 10 pul. Redondo - Horiz. transici6n frente / atr&s Broan Modelo Broan 437 Tapa del techo redondo de 10 pul. Equivalente largo 454 4 1A pul. x 18 1A pul. a 10 pul. Redondo - Horiz. transici6n derecha Equivalente Modelo Broan 410 Recto conducto 40 pies largo (25 pies sin compuerta de tira) 12 pies 10 pul. redondo x 2 pies de largo Equivalente largo 2 pies _) Modelo Broan 415 Codo redondo de 7 pul. Equivalente Modelo Broan 441 Tapa del muro redondo de 10 pul. Equivalente largo Modelo Broan 453 4 V2 pul. x 18 1Apul. a 10 pul. Redondo - Horiz. transici6n izquierda Equivalente largo 40 pies (25-ft. w/o damper) 12 pies largo 8 pies Modelo Codo redondo Modelo Broan 418 de 10 pul. Equivalente largo 10 pies Modelo Broan 427 4 tA pul. x 18 1A pul. a 10 pul. Redondo, 6 pul. alturatransici6n lateral Equivalente largo Broan sin compuerta de tira) NUMERO SEARS son disponibles por su local tienda Sears, en line& en Sears.corn, o por Piezas Sears al 1-800-366-7278. Por la disponibilidad de los modelos de Broan, amar a 1-800-558-1711 por favor. 2 pies 423 4 tA pul. x 18 tA pul. a 10 pul. Redondo transici6n vertical Equivalente 59091 30 pies (7 pies Modelo Sears Tapa del techo (7 pul. redondo) Equivalente largo largo 2 pies 18 i i 1. La campana Kenmore Elite Series 51000 debe ser instalada con ventiladores modelos 51200, 51600 o 57745 solamente. Otros ventiladores no debe ser utilisado. (Ventiladores vendidos separadamente.) Planifique donde y como se van a colocar los conductos. Instale ductos, transiciones, codos y remate de pared o de techo de tamaSo adecuado para el tipo de ventilador que este usando. Utilizar un minimo de transicion y codos per obtener el mejor resultados. A continuacion instalaciones se m&s la campana 30" sobre dimensiones para las z.g deber& estar entre 24" y el nivel de la superficie para un m_ximo cocinar. :_ de Techo Gabinete I est_indar 8' (2,44 m)de estbndar de | t8" (457 ram) I de altura s0breI la superficie I. \ 7" (178 ram) 19" I (483 ram) paracocinar p 305 las Ajuste sus medidas para las diversas alturas de techos, intrados, gabinetes o superficies para cocinar. Para Iograr un funcionamento adecuado, la parte inferior de REMATEDETECHO HUMERO DECORATJVO oINTRADOS_ muestran comunes. ; ,q) _= _ REMATE DEPARED de la tira de madera de montaje _" _.. Parte superior _" REDONDO 7"(178mm) t 24" A 30" (009 A 762 mm) SOBRE EL NIVEL DE LA SUPERFtCIE PARA COCINAR Placa 24" salpicaduras para Series 571 minima Distancia entre la (opcional) campana (610 mm) f,.% y (b la superficie CON 1 VENTILADOR CONDUCTOS TIPICOS DE MODELO 51600 para cocinsr Superficie est_ndar de _ para _ cocinar REMATEDETECHO \ Superficie para cocinar de altura 36" (914 mm) HH0028E I DUCTO REDONDO (254 mm) INSTALACION CON UN GABINETE ESTANDAR DE 18" DE I ALTURA SOBRE LA SUPERFICIE PAPA COCINAR -- I HUMERO DECORATIVO olNTRADOS_ REMATE 305 DE PARED Intrados II _ _' esandar de /| 12" 305mm 12" -0-Chimenea (305 mm) _ deintrados II | 13" Series 5511, _,(330/ mm) CAMPANA / REDONDA 4/2" x 18-1/2" 10" t (1t4 254 x 470 ram) a a 24" A 30" (609 a 762 mm) SOBRE EL NIVEL DE LA SUPERFICIE PARA COCINAR madera de montaje CON 2 VENTILADORES de la tira de T EXTERIOR -- DUCTO REDONDO 10"(254mm) | Placa para _ salpicaduras Series 571 (opcional) I I HUMERO DECORATWO o INTRADOS "_" _" N Parte superior CONDUCTOS TIPICOS DEL MODELO 51200 VENTILADOR Techo est_ndar de 8' (2,44 m) m&xima entre la 30" (762 ram) CODO - Distancia REDONDO 10" (254 mm) campana y la superficie _EXTERIOR PLACA DEL VENTILADOR 58140 m Superficie m para cocinsr t -- Superficie para cocinar estandar de 36" (914 mm) de altura para m cocinar u m HH0027E 24" A 30" (609 a 762 mm) SOBRE EL NIVEL DE LA SUPERFICIE PARA COCtNAR INSTALACION CHIMENEA CON UN INTRADOS ESTANDAR DE INTR/_,DOS OPCIONAL DE SERIES 12" 551 o (b L-" R" I CONDUCTOS EXTERIOR TIPICOS MODELO DEL VENTILADOR 57745 19 1. Usando un destornillador Phillips #2 o un Robertson #2, destornille la campana del fondo de la canasta. Refierase a la figurar para Iocalizar los 4 tornillos. Tire los tornillos y quite la campana de la paleta de madera. 4. 0, 0, 0- 0* .1 .3 2" o o HR0002 I OPCION I Una placa para salpicaduras es disponible (refierse en p&gina 17 para mas informacion). Este placa para salpicaduras se debe instalar antes que la campana debico a que este cubre los tornillos de montaje de la placa para salpicaduras. Para instalar este placa, asegurese de tener 18" (457 mm) entre debajo de la campana y el panel de control de la cocina o encima de la cocina. (Vea las instructionnes incluidas con la placa para salpicaduras.) 2. En la pared, mida y marque una linea de nivel para la tira de montaje de madera (vea las dimensiones en las ilustraciones al lado y del paso 2 en pagina 19). Usando los tomillos con plana cabeza #10-2" (incluye en bolsa de piezas), asegure la tira de montaje a la pared de manera de alcanzar los traversaSos de la pared. _b 3) 13" (330 ram) o 19" (483 ram) de techo (yea p&gina 19) campana, asegt_rese de queal lapeso tira dede madera PRECAUCI6N: Debido esta este montada directamente a todos los traversaSos de la pared disponible (el entramado de la pared), (un minimo de 2 traversa_os para una campana de 30", m_s por una mas larga); no s61o a la pared sin refuerzo. 1 1/2" (38 mm) HD0068E 1. Pared 2. Tira de madera 3. 4. 5. 6. 20 Tornillos de cabeza plana Localizacion de las anclas Atras de la pared TraversaSos de la pared 1.Parainstalar lacampana ensulugar, Uselatirademadera paraapoyar lacavidad delapartedeatr&s delacampana. PRECAUCION: Sostenga que este completamente de montura. Encima (Vista la campana haste enroscado a la tira de la campana en el interior) por tornillos Segure la campana a la tira de la montura con los (4) tornillos #8 - 3/4" (para una campana de 30" o 36" larga) o (6) tornillos (para una campana de 42" larga) incluidos, en lugar indicado. Perfora (2) agujeros de 3/16" de largo en la pared para las anclas de pared en lugar indicado. Entonces, instale las (2) anclas de la pared y asegure la campana con los tornillos #8 - 3/4" y las (2) arandellas. m m HD0064 2. Monte la transicion (si requerida) en la placa Consulta la pagina 17 por los n0meros disponibles. Use cinta para ductos seguras y hermeticas. para que todas del ventilador. de modelos las juntas m m sean 2 La placa del ventilador modelo 51600 se conecta directamente al conducto redondo de 7", sin transici6n. El ventilador exterior modelo 57745 use la placa del ventilador modelo 58140 que se conecta directamente al conducto redondo de 10", sin transicion. O, m HD0049 m 3. Tienda el cable de energia al sitio de la instalacion. Por detalles referente a la instalacion de los ventilador/placa del ventilador vea las instrucciones incluida con esa (vendida separadamente). Instale la placa de tal forma que la caja de cableado este fuera a la derecha, cuando ustedes hace frente a la campana. "S" N Si usted seleccione escape por detras, quite la placa de detr&s de la campana y instale la placa sobre encima. Asegure la placa del ventilador al interior de la campana, usando los mismo (4) tuercas. Si usted seleccione escape por encima, quite la placa de encima de la campana y instale la placa sobre detr&s. Conecte el ducto redondo a la transici6n o a la placa ventilador. Use cinta para ductos para que todas juntas sean seguras y hermeticas. del las HD0063 m (a (a 21 ,_ 1. Retire la cubierta poner a un lado. La instalacibn electrica ADVERTENCIA: Peligro de debe choque ser hecha electrico. por personal calificado de acuerdo con todos los codigos aplicables y normas. Antes de efectuar el empalme, cortar la alimentacion electrica del interruptor y cerrar con seguridad para prevenir una alimentacion accidental. del cableado de lal place del ventilador 2. Abra el agujero ciego en la caja de cableado de la placa del ventilador. Mientras instale la placa del ventilador, tienda 6" del cable de energia y conecte el cable a la caja de cableado usando el conector adecuado. 3. Conecte el cable NEGRO al NEGRO, el BLANCO al BLANCO y el VERDE o descubierto a el tomillo VERDE que toma de tierra. Vuelva a colocar la cubierta del cableado. INTER. LAMPARA TERMOGENA 120V60Hz ENCHUFE_, NEMA 5-15P V_. N / HAClA MOTOR [ DERECHA TERMOSTATO H!:_ CASQUILLO LAMP. I_TER_TILADOR B N _ _ CONTRO BOASQUILLOBOMBILLADEREOHA N VELOC+DAD _ f- I N DELUZ I N _ B / /:ASOUILLOBOMBOE +N; / ASOU+L'-OBOM°.,Z INTER. LAMP. TERM. IZQ N O B i I OPCION I Una chimenea de intrados es dispanible conductos si la campana no es instalada gabinete. Vea la instrucciones incluidas con de intrados opcional. I Refierse en p_gina 17 para informaci6n 1. Para instalar el ventilador, vea las con el ventilador. Una vez que el conecte el ventilador y el cable enchufe al interior de la campana. cablos juntos. sobre para ocultar debajo un la chimenea pedido. ] instrucciones incluidas ventilador este instale, de la caja electrica al NO CONECTE los dos Refierse en p_gina 17 para informaci6n sobre el ventilador/placa del ventilador 2. Instale (2) bombillas termogenas. Usar bombillas tamaSo BR40, 250W Max., infrarroja solamente incluydo). Instale (3) bombillas halogenas. Usar bombillas tamaSo PAR20 50W (no incluydo). de (no HE0003 de 1 Vea la p_gina 16 para informaci6n sobre bombillas. Refierse a la t_ltima p&gina para informaci6n sobre pedido. I J 22 y PRECAUCION: Antes de peliculas de plastico sobre la instalaci6n, los filtros. Es recomandable de instalar los filtros de terminar con el filtro del centro. 1) Insertar la parte superior del filtro de la palangana). 2) Acer girar la parte inferior hacia el 3) Instale el filtro debajo el ataredo y 4) Empleando la palangana, resbale de retenido interior. de lado sacar en primer en la campana las y (al lado m interior de la campana. tire. el filtro debajo la pieza m m m 2 O, HD0065 m m r_ "6" HD0024 N Filtros de sustituci6n son disponibles. a la _ltima p_gina para informaci6n sobre Refierse I OPCION I pedido. I l Filtrosde zig zag son disponibles.Para pedirlos,refierse a el dibujo debajo para encontar el numero del equipo correcto para su campana. Para instalardos, refierse a la hoja de instalacion que se encuentran incluida con los filtros a zig zag. I Refierse en p_gina EQUIPO 50030 50036 50042 # 17 para informaci6n LARGO sobre pedido. II DE CAMPANA 30" 36" 42" m N F," 23 I 17 \ 18 15 HLO031 CLAVENC 1 2 3 4 5 6 PIEZA NO. V05529 V02264 V02773 V02772 V03435 V03436 V02563 V03502 V03503 10 11 12 13 14 15 V03504 V03501 V03505 V03517 V03519 V03520 V00673 V02512 V01869 DESCRIPCI()N Logotipo Kenmore Elite Casquete de porcelana Conectador macho por motor Conectador hemera pot motor Termostato Soporte por termostato Interruptor simple SPST para lampara term6gena Interruptor doble SPST para lampara hal_x:jena Interruptor simple illuminado SPST para ventilador Bot6n control de velocidad Control de velocidad Terminal de conexion Cable de alimentaci6n Cable de control Cable de interruptor iluminado Tuerca dentellada 8-32 Tornillo mecanico 8-32 x ½ Tornillo mecanico 6-32 x % CLAVE NO PIEZANO. 16 V01582 17 V05522 V05523 V05524 18 19 20 21 22 V14763 V14764 V14765 V05528 V05521 V14744 V14745 V05526 V12971 V02544 DESCRIPClON Tuerca dentellada 6-32 Filto a rejacuba 9.5x 15.25x 0.355 campana 30" (3 requeredos) Fireoarejacuadrada 11.61x 15.25x0.355 campana 36" (3 requeredos) Htroa_acuadrada 13.61xl 525x0.355 campana 42" (3 requeredos) Canal 30" Canal 36" Canal 42" Grapa de filtro 5.265" x 0.350" Banda sellara 20.625" Pared interior izquierda Pared interior derecha Manual de instaladon por Kanmore Elite Bolsa de instalaci6n (torn. con plana cabeza#10xZ'(4), tom. #8x3/4" (8), Tuercas #10-32 (4), Anclas de la pared (2),Arandallas 3/16" ID x3/4" OD) Bombilla hal6gena PAR20 50W Bombillaterm6gena BR40, 250W max. Pida piezas de repuesto dando como referencia PIEZA- no el No. DE CLAVE. * Herraje estandar - c6mprela ** No se muestra. a un distribuidor el No. DE local.
This document in other languages