Download Dell PowerEdge M605 Owner's Manual
Transcript
Dell™ PowerEdge™ M905, M805, M600, and M605 Hardware Owner’s Manual w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2007–2008 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Inc.; AMD and AMD Opteron are trademarks of Advanced Micro Devices, Inc.; Intel and Xeon are registered trademarks of Intel Corporation; Microsoft, MS-DOS, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; Cisco is a registered trademark of Cisco Systems Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. August 2008 P/N W002C Rev. A00 Contents 1 About Your System . . . . . . . . . . . . . . . . . Other Information You May Need System Overview . . . . . . . . . . . . 11 . . . . . . . . . . . . . . . . . . . . 12 System Control Panel Features LCD Module 11 . . . . . . . . . . . . . 14 . . . . . . . . . . . . . . . . . . . . . . . 15 LCD Module Features . . . . . . . . . . . . . . . . . . . . . . . . . . 17 . . . . . . . . . . . . . . . . . . . . . 20 Using the LCD Module Menus Blade Features 16 . . . . 23 Hard-Drive Features . . . . . . . . . . . . . . . . . . . 23 Back-Panel Features . . . . . . . . . . . . . . . . . . 26 Using USB Diskette or USB DVD/CD Drives . . . . . . . . . . . . . . 27 . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . . . . . . 30 Power Supply Indicator Fan Module Indicators iKVM Module Tiering the Avocent iKVM Switch From a Analog KVM Switch . . . . . . . . . . . . . . . . 33 Tiering the Avocent iKVM Switch From a Digital KVM Switch . . . . . . . . . . . . . . . . . 35 . . . . . . . . . . . . . . . . . . . . . . 38 CMC Module . I/O Connectivity . . . . . . . . . . . . . . . . . . . . . Guidelines for Installing I/O Modules Mezzanine Cards 42 . . . . . . . 42 . . . . . . . . . . . . . . . . . . 43 Contents 3 I/O Module Port Mapping . . . . . . . . . . . . . . . . 53 . . . . . . 54 . . . . . . . . . . . . . . . 55 Cisco SFS M7000e Infiniband Switch Module PowerConnect M6220 Ethernet Switch Module . . . . . . . . . . . . . . . . . Cisco Ethernet Switch Fibre Channel Pass-through Module . 61 64 . . . . . . . . . . . . . . . . . . . . 66 Warning Messages . . . . . . . . . . . . . . . . . . . Diagnostics Messages 2 58 . . . . . . . . . Ethernet Pass-through Module Alert Messages . . . . . . . . . . . . . . . . . Brocade M4424 SAN I/O Module System Messages 78 . . . . . . . . . . . . . . . . . . . . . 78 . . . . . . 79 . . . . . . . . . . 79 . . . . . . . . . . 79 . . . . . . . . . 80 . . . . . . . . . . . . . . . . . . 80 . . . . . . . . . . . . . . . . . . . . 80 Entering the System Setup Program . Responding to Error Messages Using the System Setup Program System Setup Options Main Screen . . . . . . . . . . . . 83 . . . . . . . . . . . . . . 84 Memory Information Screen CPU Information Screen Integrated Devices Screen . . . . . . . . . . . . . Serial Communication Screen . . . . . . . . . . . 86 87 . . . . . . . . . . . . . . 87 . . . . . . . . . . . . . . . . . . . . . 89 System Security Screen Contents 85 . . . . . . Embedded Server Management Screen 4 77 . . . . . . . . . . . . . . . . . Using the System Setup Program Exit Screen 46 System and Setup Password Features . . . . . . . . . 90 . . . . . . . . . . . . 90 . . . . . . . . . . . . . 93 Using the System Password Using the Setup Password Disabling a Forgotten Password Acquiring the asset.com Utility 3 . . . . . . . . . . . . 94 . . . . . . . . . . . . . 94 Installing Blade Components . . . . . . . . . 95 . . . . . . . . . . . . 96 Removing a Blade . . . . . . . . . . . . . . . . . 96 Installing a Blade . . . . . . . . . . . . . . . . . . 98 Removing and Installing a Blade Removing and Installing a Blade Blank . . . . . . . . 99 Removing a Blade Blank . . . . . . . . . . . . . . 99 Installing a Blade Blank . . . . . . . . . . . . . . 99 Opening and Closing the Blade . . . . . . . . . . . . . 100 Opening the Blade . . . . . . . . . . . . . . . . . 100 Closing the Blade . . . . . . . . . . . . . . . . . 104 . . . . . . . . . . . . . . . . . . . . . 105 System Memory System Memory - PowerEdge M905 . . . . . . . . 105 System Memory - PowerEdge M805 . . . . . . . . 108 System Memory - PowerEdge M600 . . . . . . . . 112 System Memory - PowerEdge M605 . . . . . . . . 114 Installing Memory Modules . . . . . . . . . . . . 120 Removing Memory Modules . . . . . . . . . . . . 122 . . . . . . . . . . . . . . 123 I/O Module Mezzanine Cards Installing a Mezzanine Card . . . . . . . . . . . . 124 Removing a Mezzanine Card . . . . . . . . . . . . 126 Installing an SD Card (PowerEdge M905 and M805) . . . . . . . . . . . . . . . . . . . . . 126 Contents 5 Integrated NIC Hardware Key Processors . . . . . . . . . . . . . . 127 . . . . . . . . . . . . . . . . . . . . . . . . 128 . . . . . . . . . 128 Removing a Processor . . . . . . . . . . . . . . . 129 Installing a Processor . . . . . . . . . . . . . . . 136 Processor Installation Guidelines HT Bridge Card (Service Only) . . . . . . . . . . . . . . . . 140 . . . . . . . . . . . . . . . . . . . . . . . 142 Blade System Board NVRAM Backup Battery Hard Drives . . . . . . . . . 142 Installing a Hard Drive . . . . . . . . . . . . . . . 142 Removing a Hard Drive . . . . . . . . . . . . . . . 143 Hard-Drive Installation Guidelines Configuring the Boot Drive . . . . . . . . . . . . . Removing a Hard Drive From a Hard-Drive Carrier . . . . . . . . . . . . . . . . . . . Video Controller . . . . 144 144 . . . . . . . . . . . . . . . . . . . . . 145 Hard-Drive Backplane . . . . . . . . . . . . . . . . . . Blade System Board (Service Only) . . . . . . . . . . . 150 . . . . . . . . . . . . 150 Installing the System Board . . . . . . . . . . . . 153 . . . . . . . . . 154 Removing the Storage Controller Board . . . . . . 154 Installing the Storage Controller Board . . . . . . 155 Installing Enclosure Components Power Supply Modules . . . . . . . . . . . . . . . . . . . . . . Power Supply Blanks . 157 158 . . . . . . . . . . . . . 158 . . . . . . . . . . . . . . . 158 System Power Guidelines Contents 148 Removing the System Board Storage Controller Card (Service Only) 6 144 . . . . . Installing a Hard Drive In a Drive Carrier 4 138 Removing a Power Supply Module . . . . . . . . 159 . . . . . . . . . 160 . . . . . . . . . . . . . . . . . . . . . . 161 Installing a Power Supply Module Fan Modules . Removing a Fan Module . . . . . . . . . . . . . . 161 Installing a Fan Module . . . . . . . . . . . . . . 162 . . . . . . . . . . . . . . . . . . . . . . 162 CMC Module . Removing a CMC Module . . . . . . . . . . . . . 164 . . . . . . . . . . . . . 165 . . . . . . . . . . . . . . . . . . . . . . 166 Installing a CMC Module . iKVM Module . . . . . . . . . . . . 166 . . . . . . . . . . . . . 166 . . . . . . . . . . . . . . . . . . . . . . . 166 Removing an iKVM Module Installing an iKVM Module I/O Modules 162 . . . . . Installing an SD Card in the CMC Module . . . . . . . . . . . . . 166 . . . . . . . . . . . . . . 167 . . . . . . . . . . . . . . . . . . . . . 168 Removing an I/O Module . Installing an I/O Module Enclosure Bezel . . . . . . . . . . 168 . . . . . . . . . . . 169 Removing the Enclosure Bezel . Installing the Enclosure Bezel Enclosure Midplane (Service Only) . . . . . . . . . . . Removing the Front Module Cage Assembly and Midplane . . . . . . . . . . . . . . . . . Installing the Midplane and Front Module Cage Assembly . . . . . . . . . . . . . . . 169 . . . 169 . . . . 172 Enclosure Control Panel Assembly (Service Only) . . . 173 Removing the Enclosure Control Panel . . . . . . 173 Installing the Enclosure Control Panel . . . . . . . 174 . . . . . . . . . . . . . . . . . . . . . . . 175 LCD Module . . . . . . . . . . . . 175 . . . . . . . . . . . . . 177 Removing the LCD Module . Installing the LCD Module Contents 7 5 Troubleshooting Your System . . . . . . . . Safety First—For You and Your System Start-Up Routine . . . . . . . . . 179 . . . . . . . . . . . . . . . . . . . . . 179 Checking the Equipment . . . . . . . . . . . . . . . . . Troubleshooting External Connections Troubleshooting Video 180 . . . . . . . . . . . . . . . 180 Troubleshooting the Mouse . . . . . . . . . . . 181 . . . . . . . . . . . . 182 Troubleshooting USB Devices . . . . . . . . . . . Responding to a Systems Management Alert Message . . . . . . . . . . . . . . . . . . . . Troubleshooting a Wet Enclosure . 183 . . . . . . . . . . . 183 . . . . . . . . . Troubleshooting Enclosure Components . . . . . . . . 185 185 . . . . . 186 . . . . . . . . . . . 186 Troubleshooting Power Supply Modules Troubleshooting Fan Modules 183 . . . . . Troubleshooting a Damaged Enclosure Troubleshooting the CMC Module . . . . . . . . . 187 Troubleshooting the iKVM Module . . . . . . . . . 188 . . . . 189 Troubleshooting Blade Components . . . . . . . . . . 191 Troubleshooting Blade Memory . . . . . . . . . . 191 . . . . . . . . . . . . 192 Troubleshooting a Network Switch Module Troubleshooting Hard Drives Troubleshooting Microprocessors . . . . . . . . . 193 Troubleshooting the Blade Board . . . . . . . . . 194 Troubleshooting the NVRAM Backup Battery Contents 180 . . . . . . . . . Troubleshooting the Keyboard 8 179 . . . 195 6 Running System Diagnostics . . . . . . . . . Using Server Administrator Diagnostics System Diagnostics Features . . . . . . . . 197 . . . . . . . . . . . . . . 197 When to Use the System Diagnostics . . . . . . . . . . 198 . . . . . . . . . . . . 198 From the Utility Partition . . . . . . . . . . . . . . 198 From a USB Flash Drive . . . . . . . . . . . . . . 198 Running the System Diagnostics System Diagnostics Testing Options . . . . . . . . . . 199 Using the Advanced Testing Options . . . . . . . . . . 200 . . . . . . . . . . . . . . . . . . . . . 201 Error Messages 7 197 System Board Information . . . . . . . . . . Blade System Board Jumper Settings 203 . . . . . . . . . 203 PowerEdge M905 Jumper Settings . . . . . . . . 203 PowerEdge M805 Jumper Settings . . . . . . . . 204 PowerEdge M600 Jumper Settings . . . . . . . . 204 PowerEdge M605 Jumper Settings . . . . . . . . 206 . . . . . . . . . . . . . . . 207 System Board Connectors . PowerEdge M905 System Board . . . . . . . . . . 207 PowerEdge M805 System Board . . . . . . . . . . 209 PowerEdge M600 System Board . . . . . . . . . . 211 . . . . . . . . . . 213 . . . . . . . . . . . . 214 PowerEdge M605 System Board Disabling a Forgotten Password Contents 9 8 Getting Help . Contacting Dell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 217 Glossary 219 Index 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents 231 About Your System Other Information You May Need CAUTION: The safety instructions that came with your system provide important safety and regulatory information. Warranty information may be included within this document or as a separate document. • The Rack Installation Guide or Rack Installation Instructions included with your rack solution describes how to install your system into a rack. • The Getting Started Guide provides an overview of system features, setting up your system, and technical specifications. • The Configuration Guide provides information on initial configuration of the blades and other modular components in your system. • The Dell Chassis Management Controller User’s Guide and Integrated Dell Remote Access Controller User’s Guide provides detailed information on using the remote management features of your system, including the CMC, iDRAC, and iKVM. • User documentation for the Ethernet, Fibre Channel, Infiniband, or other I/O modules purchased with your system. • CDs included with your system provide documentation and tools for configuring and managing your system. • Systems management software documentation describes the features, requirements, installation, and basic operation of the software. • Operating system documentation describes how to install (if necessary), configure, and use the operating system software. • Documentation for any components you purchased separately provides information to configure and install these options. • Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. NOTE: Always check for updates on support.dell.com and read the updates first because they often supersede information in other documents. About Your System 11 • Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians. System Overview Your system can include up to 16 half-height blades (server modules), eight full-height blades, or a mixture of the two blade types (see Figure 1-1, Figure 1-2, and Figure 1-3). To function as a system, a blade is inserted into a enclosure (chassis) that supports power supplies, fan modules, a Chassis Management Controller (CMC) module, and at least one I/O module for external network connectivity. The power supplies, fans, CMC, optional iKVM module, and I/O modules are shared resources of the blades in the PowerEdge M1000e enclosure. NOTE: To ensure proper operation and cooling, all bays in the enclosure must be populated at all times with either a module or with a blank. Figure 1-1. 12 Blade Numbering – Half-Height Blades 1 2 3 4 5 6 7 9 10 11 12 13 14 15 About Your System 8 16 Figure 1-2. Blade Numbering - Full Height Blades 1 Figure 1-3. 2 3 4 5 6 7 8 Blade Numbering - Mixed Full-Height and Half-Height Blades 1 2 3 4 5 13 6 14 7 8 15 16 About Your System 13 System Control Panel Features Figure 1-4. Control Panel Features 2 3 1 14 4 5 1 USB port (mouse only) 2 USB port (keyboard only) 3 video connector 4 system power button 5 power indicator About Your System . Table 1-1. Control Panel Features Feature Indicator Description System power button N/A Turns the system on and off. Press to turn on the system. Press and hold 10 seconds to turn off the system. NOTE: The system power button controls power to all of the blades and I/O modules in the enclosure. System power indicator Off Enclosure does not have power. Green System power is on. Amber Enclosure is plugged in but enclosure power is not turned on. NOTE: An amber power LED does not indicate an enclosure error. USB ports for keyboard and mouse N/A Functional if an optional iKVM module is installed and front panel ports are enabled (default setting) in the CMC interface. NOTE: These ports do not support USB storage devices. Only connect USB storage devices to the USB ports on the front panel of the blade. Video connector N/A Functional if an optional iKVM module is installed and front panel ports are enabled (default setting) in the CMC interface. LCD Module The LCD module provides an initial configuration/deployment wizard, as well as easy access to infrastructure and blade information, and error reporting. See Figure 1-5. About Your System 15 Figure 1-5. LCD Display 3 2 1 1 LCD screen 3 selection ("check") button 2 scroll buttons (4) LCD Module Features The primary function of the LCD module is to provide real-time information on the health and status of the modules in the enclosure. LCD module features include: 16 • A deployment setup wizard that allows you to configure the CMC module’s network settings during initial system set up. • Menus to configure the iDRAC in each blade. • Status information screens for each blade. About Your System • Status information screens for the modules installed in the back of the enclosure, including the IO modules, fans, CMC, iKVM, and power supplies. • A network summary screen listing the IP addresses of all components in the system. • Real time power consumption statistics, including high and low values, and average power consumption. • Ambient temperature values. • AC power information • Critical failure alerts and warnings. Using the LCD Module Menus Table 1-2 lists the keys that you use to view or change information on the LCD module screens. Table 1-2. LCD Module Screen Navigation Keys Keys Action Left and right arrows Move between screens. Up arrow or down arrow Move to the previous or next option on a screen. Center button Select and save an item and move to the next screen. Configuration Wizard When you first start up your system, you will be directed to configure the CMC network settings. The configuration wizard also automatically configures each blade’s iDRAC internal network interface. The iDRAC IP addresses are incremented from the CMC IP address. NOTE: After you run the configuration wizard, this option will no longer be available on the LCD menus. 1 Choose a language from the options presented in the dialog box. 2 Start the configuration wizard. About Your System 17 3 Configure the CMC network settings for your network environment: • Network speed • Duplex mode • Network mode (DHCP or static) • Static IP address, subnet mask, and gateway values (if static mode was selected) • DNS settings 4 If desired, configure the iDRAC network settings. See the CMC User’s Guide for detailed information about the iDRAC. NOTE: The configuration wizard will automatically configure each blade’s iDRAC internal network interface if you do not choose to manually configure the iDRAC settings. NOTE: You cannot set a static IP address for the iDRAC using the LCD Configuration Wizard. To set a static IP address, use the CMC Web-based interface or RACADM. 5 Review the settings on the Network Summary screen. • If the settings are correct, press the center button to close the configuration wizard and return to the Main Menu. • If the settings are not correct, use the left arrow key to return to the screen for that setting and correct it. After you complete the configuration wizard, the CMC will be available on your network. Main Menu The Main Menu options include links to the Server Menu, the Enclosure Menu, and the LCD Setup Menu. LCD Setup Menu You can change the default language and startup screen for the LCD menu screens using this menu. 18 About Your System Server Menu From the Server Menu dialog box, you can highlight each blade in the enclosure using the arrow keys, and view its status. • A blade that is powered off or booting is designated by a gray rectangle. An active blade is indicated by a green rectangle. If a blade has errors, this condition is indicated by an amber rectangle. • To select a blade, highlight it and press the center button. A dialog box displays the iDRAC IP address of the blade and any errors present. Enclosure Menu The Enclosure Menu includes options for Module Status, Enclosure Status, and Network Summary. • • In the Module Status dialog box, you can highlight each component in the enclosure and view its status. – A module that is powered off or booting is designated by a gray rectangle. An active module is indicated by a green rectangle. If a module has errors, it will be indicated by an amber rectangle. – If a module is selected, a dialog box displays the current status of the module and any errors present. In the Enclosure Status dialog box, you can view the enclosure status, any error conditions, and power consumption statistics. About Your System 19 Blade Features Figure 1-6. Front Panel Features - PowerEdge M600 and M605 1 2 6 5 4 3 20 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator About Your System Figure 1-7. Front Panel Features - PowerEdge M905 and M805 1 2 6 5 4 3 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (3) 5 blade power button 6 blade power indicator About Your System 21 Table 1-3. Blade Control Panel Features Feature Icon Blade power indicator Description Off – Power is not available to the blade, the blade is in standby mode, the blade is not turned on, or the blade is installed incorrectly. For detailed information on installing a blade, see "Installing a Blade" on page 98. Green increasing from low brightness to full brightness – Blade power on request is pending. Green on – The blade is turned on. Blade status/ identification indicator Off – The blade power is off. Blue – Normal operating state Blue blinking – The blade is being remotely identified via the CMC. Amber blinking – Blade has either detected an internal error, or the installed mezzanine card(s) does not match the I/O modules installed in the M1000e enclosure. Check the CMC for an I/O configuration error message and correct the error. Blade power button N/A Turns blade power off and on. • If you turn off the blade using the power button and the blade is running an ACPI-compliant operating system, the blade can perform an orderly shutdown before the power is turned off. • If the blade is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed. • Press and hold the button to turn off the blade immediately. The blade power button is enabled by default by the System Setup program.(If the power button option is disabled, you can only use the power button to turn on the blade. The blade can then only be shut down using system management software.) USB connector 22 About Your System Connects external USB 2.0 devices to the blade. Using USB Diskette or USB DVD/CD Drives Each blade has USB ports on the front of the blade which allows you to connect a USB diskette drive, USB flash drive, USB DVD/CD drive, keyboard, or mouse. (PowerEdge M905 and M805 blades have three USB ports; PowerEdge M605 and M600 blades have two ports.) The USB drives can be used to configure the blade. NOTICE: The system supports only Dell-branded USB 2.0 drives. The drive must be horizontal and level to operate properly. Use the optional external drive storage tray to support the drive while in use. NOTE: If the drive must be designated as the boot drive, connect the USB drive, restart the system, then enter the System Setup Program and set the drive as first in the boot sequence (see "Using the System Setup Program" on page 79). The USB device will be displayed in the boot order setup screen only if it is attached to the system before you run the System Setup program. You can also select the boot device by pressing the <F11> key during system startup and selecting a boot device for the current boot sequence. Hard-Drive Features • The PowerEdge M805 and M905 blades support one or two hot-pluggable 2.5 inch SAS hard drives. • The PowerEdge M600 and M605 blades support one or two hot-pluggable 2.5-inch SATA hard drives or one or two 2.5 inch SAS hard drives. NOTE: SAS and SATA hard drives cannot be mixed within a blade. NOTE: SATA hard drives are not hot pluggable with the SATA repeater daughter card. Hot-plug drive operation is supported if an optional RAID controller card is installed in the blade. On blades with a diskless configuration, no disk controller is included in the blade, but hard-drive blanks and the internal storage backplane must be present to maintain proper airflow. See Figure 1-8 and Table 1-4 for information on the hard-drive indicators. Different patterns are displayed as drive events occur in the system. NOTICE: The blade must have a hard drive or a hard-drive blank installed in each hard-drive bay. About Your System 23 NOTE: The hard-drive status indicator is only functional for RAID hard drive configurations. For non-RAID configurations, only the drive-activity indicator is active. Refer to the Dell RAID controller documentation to service a RAID volume, rebuild an array, or swap RAID members. Figure 1-8. Hard-Drive Indicators 1 1 24 2 activity indicator About Your System 2 status indicator (RAID drives only) Table 1-4. Hard-Drive Indicator Patterns Indicator State Description Activity indicator Off Drive is not being accessed On Drive is being accessed Off • Drive is ready for removal. • Drive bay is empty. • Power is off to the blade. Green Drive is online. Green, blinking slowly Drive is rebuilding. Green, blinking quickly Drive is being identified. Amber Drive has failed or has an error. See "Troubleshooting Hard Drives" on page 192. Amber blinking slowly, Green blinking slowly, then off The drive has reported a predictive failure event, and should be replaced. Status indicator (SAS drives with optional RAID controller only) About Your System 25 Back-Panel Features Figure 1-9. Back-Panel Features 2 3 4 5 1 6 26 1 fan modules (9) 2 primary CMC module 3 I/O modules (6) 4 optional iKVM module 5 secondary CMC module 6 power supplies (6) About Your System Figure 1-10. Back-Panel Module Bay Numbering C2 B2 A2 iKVM A1 B1 C1 CMC 1 CMC 2 1 2 3 4 5 6 7 8 9 1 2 2 3 4 5 6 Power Supply Indicator NOTICE: The power supplies must be connected to a PDU, not directly to an electrical outlet. The power supplies require a 200–240 V power source. About Your System 27 Figure 1-11. Power Supply Indicators 1 2 3 1 DC power output indicator 3 AC power present indicator Table 1-5. 2 power supply fault indicator Power Supply Indicators Indicator Icon Indicator Description Color DC power output good Green The power supply is operational and DC power is being supplied by the power supply. Fault indicator Amber The power supply is in a fault condition, which can result from either a failed power supply or a failed fan within the power supply. See "Power Supply Modules" on page 158. 28 About Your System Table 1-5. Power Supply Indicators (continued) Indicator Icon AC power source present indicator Indicator Description Color Green The power supply is connected to an 208VAC AC power source. NOTE: This indicator will not illuminate if the power supply is connected to a 110 VAC power source. Fan Module Indicators Figure 1-12. Fan Module Indicators 1 2 1 fan power indicator 2 fan fault indicator About Your System 29 Table 1-6. Fan Indicators Indicator Indicator Description State Power indicator Green Fault indicator The power supply is connected to an 208VAC AC power source. NOTE: This indicator will not illuminate if the power supply is connected to a 110 VAC power source. Off AC power not connected. Amber The fan is in a fault condition. Off Fan not faulty. iKVM Module The optional Avocent iKVM analogue switch module includes the following features: • Local iKVM access can be remotely disabled on a per blade basis, using the blade’s iDRAC interface (access is enabled by default). NOTE: By default (enabled), a console session to a given blade will be available to both the iDRAC interface and iKVM (users connected to a blade's console via iDRAC and the iKVM will see the same video and be able to type commands). If this sharing is not desired, this can be disabled via the iDRAC console interface. • The following connectors: – One VGA connector. The iKVM supports a video display resolution range from 640x480 at 60Hz up to 1280x1024x65,000 colors (noninterlaced) at 75Hz. – Two USB ports for keyboard and mouse. NOTE: The iKVM USB ports do not support storage devices. 30 About Your System – RJ-45 ACI port for tiering with Dell and Avocent analog KVM and KVM over IP switches with ARI ports. NOTE: Although the ACI port is an RJ-45 connector and uses Cat5 (or better) cabling, it is not an Ethernet network interface port. It is only used for connection to external KVM switches with Analog Rack Interface (ARI) ports, and does not support native KVM over IP. • The iKVM can also be accessed from the front of the enclosure, providing front or rear panel KVM functionality, but not at the same time. For enhanced security, front panel access can be disabled using the CMC’s interface. NOTE: Connecting a keyboard, video, and mouse to the enclosure front panel will disable video output to the iKVM back panel port. It will not interrupt iDRAC video and console redirection. • You can use the iKVM to access the CMC console directly, using RACADM or via the Web-based interface. For more information, see "Using the iKVM Module" in the CMC User’s Guide. Figure 1-13 shows the external features of the iKVM switch module. About Your System 31 Figure 1-13. Avocent iKVM Switch Module 3 2 5 4 1 1 identification indicator 2 status indicator 3 ACI port for tiering connection only 4 USB connectors (2) for keyboard and mouse 5 video connector NOTE: Do not connect the ACI port to a LAN device such as a network hub. Doing so may result in equipment damage. 32 About Your System Table 1-7. Avocent Analog iKVM Switch Module Features Feature Indicator Pattern Description Power indicator Off iKVM switch does not have power. Green iKVM switch has power. Green flashing Firmware upgrade in progress Status/ Blue blinking identification Amber flashing indicator iKVM module is being identified. System fault or error condition. USB connectors Allows a keyboard and mouse to be connected to the system. Video connector Allows a monitor to be connected to the system. ACI port Allows connection of one or more servers to a Dell console switch with an Analog Rack Interface (ARI) port, such as an external digital or analog switch. Link indicator Off The ACI is not connected to the external switch. Green The ACI is connected to the external switch. Activity indicator Off Data is not being sent or received. Amber blinking Data is being sent or received. Tiering the Avocent iKVM Switch From a Analog KVM Switch The Avocent iKVM switch can be tiered from analog KVM switches such as the Dell 2160AS and 180AS, as well as many Avocent analog KVM switches. Many switches may be tiered without the need for a Server Interface Pod (SIP) (see Table 1-8). Table 1-8. Cabling Requirements for External Analog KVM Switches Switch Tiering Cabling Requirements Dell PowerConnect 180AS, 2160AS Seamless tiering using ACI port and Cat 5 cable Avocent Autoview 1400, 1500, 2000, 2020, 2030, Ax000R About Your System 33 Table 1-8. Cabling Requirements for External Analog KVM Switches (continued) Switch Tiering Cabling Requirements Avocent Autoview 200, 400, 416, 424 Dell USB SIP required with Cat 5 cable Avocent Outlook 140ES, 180ES, 160ES Before connecting the iKVM switch to a supported analog switch, you must set the iKVM switch to display in slot order, and set the Screen Delay Time to 1 or more seconds: 1 Press <Print Screen> to launch the iKVM Switch OSCAR. 2 Click Setup > Menu. The Menu dialog box appears. 3 Select Slot to display servers numerically by slot number. 4 Enter a screen delay time of at least 1 second. 5 Click OK. Setting the Screen Delay time to 1 second allows you to soft switch to a server without launching OSCAR. NOTE: Soft switching allows you to switch servers using a hot key sequence. You can soft switch to a server by pressing <Print Screen> and then typing the first few characters of its name or number. If you have a Delay Time set and you press the key sequences before that time has elapsed, OSCAR will not display. To configure the analog switch: 1 Press <Print Screen> to open the OSCAR Main dialog box. 2 Click Setup → Devices → Device Modify. 3 Select the 16-port option to match the number of blades in your system. 4 Click OK to exit OSCAR. 5 Press <Print Screen> to verify that the settings have taken effect. The slot number of the blade to which the iKVM switch is now attached should be expanded to display each of the slot locations of the blades in the system. For instance, if the iKVM switch is attached to slot 1, it would now be displayed as 01-01 to 01-16. 34 About Your System To connect the Avocent iKVM switch to a supported analog switch: 1 If the switch does not require a SIP to connect to the iKVM (see Table 1-8), connect a Cat5 (or newer) cable to the RJ-45 ACI port on the iKVM module. See Figure 1-13. Connect the other end of this cable to the ARI port on the external switch. If the analog switch requires a USB SIP (see Table 1-8), connect a USB SIP to the iKVM, then connect a Cat5 (or newer) cable to the SIP. Connect the other end of this cable to the ARI port on the external switch. 2 Connect both the analog switch and the system to an appropriate power source. 3 Power up the system. 4 Power up the external analog switch. NOTE: If the external analog switch is powered up before the system, it may result in only one blade displaying in the analog switch OSCAR, instead of 16. If this behavior occurs, shut down and restart the switch so the entire complement of blades is recognized. NOTE: In addition, to the steps outlined above, some external analog switches may require you to perform additional steps to ensure that the iKVM switch blades appear in the external analog switch OSCAR. See the external analog switch documentation for additional information. Tiering the Avocent iKVM Switch From a Digital KVM Switch The iKVM switch may also be tiered from a digital KVM switch such as the Dell 2161DS or 4161DS, or a supported Avocent digital KVM switch. Many switches may be tiered without the need for a SIP (see Table 1-9). Table 1-9. Cabling Requirements for External Digital KVM Switches Switch Tiering Requirements Dell PowerConnect 2161DS, 4161DS Seamless tiering using ACI port and Cat 5 cable Avocent DSR 800, x16x, x010, x031, x030, x035,102x (except 1024) Avocent DSR 1024 Dell USB SIP required with Cat 5 cable About Your System 35 To tier the iKVM switch module from a Dell 2161DS, 180AS, or 2160AS console switch: • If the switch does not require a SIP to connect to the iKVM (see Table 1-9), connect a Cat5 (or newer) cable to the RJ-45 ACI port on the iKVM module. See Figure 1-13. Connect the other end of this cable to the ARI port on the external switch. • If the switch requires a USB SIP (see Table 1-8), connect a USB SIP to the iKVM, then connect a a Cat5 (or newer) cable to the SIP. Connect the other end of this cable to the ARI port on the external switch. Once the KVM switch is connected, the server modules appear in OSCAR. NOTE: Once the local system is set up, you must also resynchronize the server list from the Remote Console Switch software in order to see the list of blades. See Resynchronizing the Server List at the Remote Client Workstation. Resynchronizing the Server List at the Remote Client Workstation Once the iKVM switch is connected, the blades appear in OSCAR. You now need to resynchronize the servers on any remote workstation to ensure that the blades are available to any remote users connected to the console switch through the Remote Console Switch software. NOTE: This procedure only resynchronizes one remote client workstation. With multiple client workstations, save the resynchronized local database and load it into the other client workstations to ensure consistency. To resynchronize the server listing: 1 Click Resync in the Server category of the Management Panel (MP). The Resync Wizard launches. 2 Click Next. A warning message displays indicating that the database will be updated to match the current configuration of the console switch. Your current local database names will be overridden with the switch names. To include unpowered SIPs in the resynchronization, click to enable the Include Offline SIPs check box. 3 Click Next. A Polling Remote Console Switch message box appears with a progress bar indicating that the switch information is being retrieved. 36 About Your System 4 If no changes were detected in the appliance, a completion dialog box appears with this information. If server changes were detected, then the Detected Changes dialog box will be displayed. Click Next to update the database. 5 If a cascade switch was detected, the Enter Cascade Switch Information dialog box appears. Select the type of switch connected to the appliance from the drop-down list. If the type you are looking for is not available, you can add it by clicking Add. 6 Click Next. The completion dialog box appears. 7 Click Finish to exit. 8 Start up the analog switch and the system. About Your System 37 CMC Module Figure 1-14. CMC Module Features 1 2 3 4 5 10 9 8 6 7 38 1 Ethernet connector Gb1 2 Ethernet connector STK ("stack") used for daisy-chaining CMCs in separate enclosures 3 link indicator (2) 4 activity indicator (2) 5 DB-9 serial connector for local configuration 6 optional secondary CMC (CMC 2) 7 primary CMC (CMC 1) 8 amber fault indicator 9 blue status/identification indicator 10 power indicator About Your System Table 1-10. CMC Module Features Indicator Pattern Description Network interface controller link indicator Off LAN is not linked. Green LAN is linked. Network interface controller activity indicator Off LAN is not active. Amber blinking Indicates that the system CMC and the LAN are communicating. Power indicator Off Status/ identification indicator Green CMC has power. Green blinking Firmware update in progress Off This CMC is the standby CMC. Blue (solid) This CMC is the primary CMC. Blue (blinking) Fault indicator Off Serial connector CMC does not have power. The CMC is being identified by the systems management software. The CMC is operating normally. Amber blinking A fault has occurred. None Used for local configuration (115200 baud, No parity, 8, 1) The CMC provides multiple systems management functions for your modular server: • Enclosure-level real-time automatic power and thermal management. – The CMC monitors system power requirements and supports the optional Dynamic Power Supply Engagement mode so that the CMC can enable or place power supplies in standby dynamically depending on load and redundancy requirements to improve power efficiency. – The CMC reports real-time power consumption, which includes logging high and low points with a time stamp. About Your System 39 • – The CMC supports setting an optional enclosure Maximum Power Limit, which will either alert or take actions, such as throttling server modules and/or preventing the power up of new blades to keep the enclosure under the defined maximum power limit. – The CMC monitors and automatically controls cooling fans based on actual ambient and internal temperature measurements. – The CMC provides comprehensive enclosure inventory and status/error reporting. The CMC provides a mechanism for centralized configuration of the following: – The M1000e enclosure’s network and security settings – Power redundancy and power ceiling settings – I/O switches and iDRAC network settings – First boot device on the server blades – The CMC checks I/O fabric consistency between the I/O modules and blades and disables components if necessary to protect the system hardware. – User access security. The CMC has two Ethernet ports: Gb1 is used to connect to the external management network. The connector labeled STK ("stack") will allow CMCs in adjacent enclosures to be daisy-chained. A 24-port Ethernet switch provides internal communication between the iDRAC on each blade, I/O modules, optional KVM, and optional second, redundant CMC. NOTE: The 24-port Ethernet switch is reserved for internal communication between the iDRAC on the blades to the CMC and the external management network. If two CMCs are installed, the heartbeat for CMC redundancy is also present and CMC redundancy is supported over this internal network. This internal network is outside the data path from host LOMs and the mezzanine cards in the blades. At least one CMC must be installed in the primary CMC bay (see Figure 1-14) for the system to power up. If a second, optional CMC module is installed, failover protection and hot-plug replacement is available. See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on how to set up and operate the CMC module. 40 About Your System Figure 1-15. CMC Daisy-Chaining 2 1 3 4 1 CMC1 – cable from connector Gb1 to network 2 CMC2 – cable from connector Gb1 to network 3 CMC2 – cable from connector STK to connector Gb1 on CMC2 in adjacent chassis 4 CMC1 – cable from connector STK to connector Gb1 on CMC1 in adjacent chassis About Your System 41 I/O Connectivity The M1000e enclosure supports three layers of I/O fabric, selectable between combinations of Ethernet, Infiniband, and fibre-channel modules. (Additional fabrics including10 Gb Ethernet will be supported in the future.) You can install up to six hot-swappable I/O modules in the enclosure, including fibre-channel switches, fibre-channel pass-throughs, Infiniband switches, Ethernet switches, and Ethernet pass-through modules. Guidelines for Installing I/O Modules You must follow these guidelines when populating I/O modules. See Figure 1-9 for the I/O bay locations. General I/O Module Configuration Guidelines 42 • If an I/O module is installed in Fabric B or Fabric C, at least one blade must have a matching mezzanine card installed to support data flow for that I/O module. • If a blade has an optional mezzanine card installed in a Fabric B or Fabric C card slot, at least one corresponding I/O module must be installed to supported data flow for that fabric • Within each fabric type, you must install a module in the fabric’s channel 1 slot before installing a module in the fabric’s channel 2 slot. For example, you must install a module in slot C1 before installing a module in slot C2. • Modules may be installed in Fabrics B and C independently (you do not need to install modules in Fabric B before installing modules in the Fabric C slots.) • Slots A1 and A2 only support Ethernet I/O modules. This fabric type is hard-set to Ethernet for these slots and cannot support Fibre Channel, Infiniband, or other fabric type modules. • Slots A, B, and C can support Ethernet fabric-type modules. • To enable switch configuration prior to blade imaging, I/O modules are allowed to power-up before a blade is inserted in the enclosure. About Your System Fabric A Fabric A is a redundant Gb Ethernet fabric, supporting I/O module slots A1 and A2. The integrated Ethernet controllers in each blade dictate Fabric A as an Ethernet-only fabric. NOTICE: Modules designed for Fabric B or Fabric C cannot be installed in slots A1 or A2. Fabric B Fabric B is a 1 to 10 Gb/sec dual port, quad-lane redundant fabric, supporting I/O module slots B1 and B2. Fabric B currently supports Gb Ethernet, Infiniband, and Fibre Channel modules. Additional fabric types including 10 Gb Ethernet will be supported in the future. To communicate with an I/O module in the Fabric B slots, a blade must have a matching mezzanine card installed in a Fabric B mezzanine card location. Modules designed for Fabric A may also be installed in the Fabric B slots. Fabric C Fabric C is a 1 to 10 Gb/sec dual port, quad-lane redundant fabric, supporting I/O module slots C1 and C2. Fabric C currently supports Gb Ethernet, Infiniband, and Fibre Channel modules. Additional fabric types including 10 Gb Ethernet will be supported in the future. To communicate with an I/O module in the Fabric C slots, a blade must have a matching mezzanine card installed in a Fabric C mezzanine card location. Modules designed for Fabric A may also be installed in the Fabric C slots. Mezzanine Cards PowerEdge M905 and M805 The full-height PowerEdge M905 and M805 blades support four mezzanine cards: • Slot Mezz1_Fabric_C and slot Mezz3_Fabric_C support Fabric C. If a card is installed in both slots, both cards must be identical. They must also match the fabric type of the I/O modules installed in I/O module bays C1 and C2. About Your System 43 • Slot Mezz2_Fabric_B and slot Mezz4_Fabric_B support Fabric B. If a card is installed in both slots, both cards must be identical. They must also match the fabric type of the I/O modules installed in I/O module bays B1 and B2. PowerEdge M600 and M605 The half-height PowerEdge M600 and M605 blades support two mezzanine cards: • Mezzanine card slot C supports Fabric C. This card must match the fabric type of I/O modules installed in I/O module bays C1 and C2. • Mezzanine card slot B supports Fabric B. This card must match the fabric type of I/O modules installed in I/O module bays B1 and B2. See "I/O Module Mezzanine Cards" on page 123 for more information on mezzanine cards. Table 1-11 shows various supported combinations of mezzanine cards and I/O modules. Table 1-11. Supported I/O Module Configurations Fabric A Fabric B Mezzanine Card Fabric C Mezzanine Card I/O Bay A1, A2 Standard Integrated LOM NIC none none Ethernet none switch module or pass-through module Standard Integrated LOM NIC Ethernet mezzanine card none Ethernet switch module or pass-through module Standard Integrated LOM NIC none Infiniband mezzanine card Ethernet none switch module or pass-through module 44 About Your System I/O Bay B1, B2 I/O Bay C1, C2 none Ethernet none switch module or pass-through module Infiniband switch module Table 1-11. Supported I/O Module Configurations (continued) Fabric A Fabric B Mezzanine Card Fabric C Mezzanine Card I/O Bay A1, A2 I/O Bay B1, B2 I/O Bay C1, C2 Standard Integrated LOM NIC Ethernet mezzanine card Ethernet mezzanine card Ethernet switch module or pass-through module Ethernet switch module or pass-through module Ethernet switch module or pass-through module Standard Integrated LOM NIC Fibre Channel mezzanine card Infiniband mezzanine card Ethernet switch module or pass-through module Fibre Infiniband Channel switch switch or module pass-through module Standard Integrated LOM NIC none Fibre Channel mezzanine card Ethernet none switch module or pass-through module Fibre Channel switch module or pass-through module Standard Integrated LOM NIC Fibre Channel mezzanine card Fibre Channel mezzanine card Ethernet switch module or pass-through module Fibre Channel switch or pass-through module Fibre Channel switch or pass-through module Standard Integrated LOM NIC Ethernet mezzanine card Fibre Channel mezzanine card Ethernet switch module or pass-through module Ethernet switch module or pass-through module Fibre Channel switch or pass-through module Standard Integrated LOM NIC Infiniband mezzanine card Infiniband mezzanine card Infiniband Ethernet switch switch module or module pass-through module Infiniband switch module About Your System 45 Table 1-11. Supported I/O Module Configurations (continued) Fabric A Fabric B Mezzanine Card Fabric C Mezzanine Card I/O Bay A1, A2 I/O Bay B1, B2 I/O Bay C1, C2 Standard Integrated LOM NIC Fibre Channel mezzanine card Ethernet mezzanine card Ethernet switch module or pass-through module Fibre Channel switch or pass-through module Ethernet switch module or pass-through module I/O Module Port Mapping The integrated LOMs and optional mezzanine card s are mapped to the I/O module ports based on the following rules: Full-Height Blades (PowerEdge M905 and M805) Each LOM or mezzanine card has two port connections. For a full-height blade in bay n: • Integrated NIC LOM1, connection 1 will connect to I/O module A1, port n. Integrated NIC LOM1, connection 2 will connect to I/O module A2, port n. • Integrated NIC LOM2, connection 1 will connect to I/O module A1, port n+8. Integrated NIC LOM2, connection 2 will connect to I/O module A2, port n+8. • Mezzanine card 1, connection 1 will connect to I/O module C1, port n. Mezzanine card 1, connection 2 will connect to I/O module C2, port n. • Mezzanine card 2, connection 1 will connect to I/O module B1, port n. Mezzanine card 2, connection 2 will connect to I/O module B2 port n. • Mezzanine card 3, connection 1 will connect to I/O module C1, port n+8. Mezzanine card 3, connection 2 will connect to I/O module C2 port n+8. • Mezzanine card 4, connection 1 will connect to I/O module B1, port n+8. Mezzanine card 4, connection 2 will connect to I/O module B2 port n+8. For example, in a full-height blade in slot 5, integrated NIC LOM1 connection 1 will connect to I/O module A1, port 5 and LOM1 connection 2 will connect to I/O module A2 port 5. NIC LOM2 connection 1 will connect to I/O module A1, port 13 and LOM2 connection 2 will connect to I/O 46 About Your System module A2, port 13. Mezzanine card 3, connection 1 will connect to I/O module C1, port 13 and Mezzanine card 3, connection 2 will connect to I/O module C2 port 13. Table 1-12 shows the port number assignments for the eight possible full height blade locations. Table 1-12. I/O Module Port Assignments - Full-Height Blades Blade 1 I/O Module A1 C1 A1 C2 B2 A2 Integrated LOM1 Port 1 Port 1 Integrated LOM2 Port 9 Port 9 Mezz1_Fab_C Port 1 Mezz2_Fab_B Port 1 Port 1 Mezz3_Fab_C Port 1 Port 9 Mezz4_Fab_B Port 9 Port 9 Blade 2 Port 9 I/O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port 2 Port 2 Integrated LOM2 Port 10 Port 10 Mezz1_Fab_C Port 2 Mezz2_Fab_B Port 2 Port 2 Mezz3_Fab_C Port 2 Port 10 Mezz4_Fab_B Port 10 Port 10 Blade 3 Port 10 I/O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port 3 Port 3 Integrated LOM2 Port 11 Port 11 Mezz1_Fab_C Mezz2_Fab_B Port 3 Port 3 Port 3 Port 3 About Your System 47 Blade 3 I/O Module A1 B1 Mezz3_Fab_C Mezz4_Fab_B C1 C2 Port 11 Port 11 Port 11 Blade 4 B2 A2 Port 11 I/O Module A1 A1 A1 C2 C2 C2 Integrated LOM1 Port 4 Port 4 Integrated LOM2 Port 12 Port 12 Mezz1_Fab_C Port 4 Mezz2_Fab_B Port 4 Port 4 Mezz3_Fab_C Port 4 Port 12 Mezz4_Fab_B Port 12 Port 12 Blade 5 Port 12 I/O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port 5 Port 5 Integrated LOM2 Port 13 Port 13 Mezz1_Fab_C Port 5 Mezz2_Fab_B Port 5 Port 5 Mezz3_Fab_C Port 5 Port 13 Mezz4_Fab_B Port 13 Port 13 Blade 6 Port 13 I/O Module A1 B1 A1 C2 B2 A2 Integrated LOM1 Port 6 Port 6 Integrated LOM2 Port 14 Port 14 Mezz1_Fab_C 48 About Your System Port 6 Port 6 Blade 6 I/O Module A1 Mezz2_Fab_B B1 A1 C2 B2 Port 6 Mezz3_Fab_C Port 6 Port 14 Mezz4_Fab_B Port 14 Port 14 Blade 7 A2 Port 14 I/O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port 7 Port 7 Integrated LOM2 Port 15 Port 15 Mezz1_Fab_C Port 7 Mezz2_Fab_B Port 7 Port 7 Mezz3_Fab_C Port 7 Port 15 Mezz4_Fab_B Port 15 Port 15 Blade 8 A1 A1 Port 15 I/O Module V A1 B2 C2 A2 Integrated LOM1 Port 8 Port 8 Integrated LOM2 Port 16 Port 16 Mezz1_Fab_C Mezz2_Fab_B Port 8 Port 8 Mezz3_Fab_C Mezz4_Fab_B Port 8 Port 8 Port 16 Port 16 Port 16 Port 16 Figure 1-16 shows the port connections for a full-height blade in bay 3 with four mezzanine cards. About Your System 49 Figure 1-16. Example of Full-Height Blade Port Mapping – Blade 3 50 About Your System Half-Height Blades (PowerEdge M600 and M605) For a half-height blade in bay n: • The integrated NIC will connect to I/O module A1, port n and I/O module A2, port n. • Mezzanine card B will connect to I/O module B1, port n and I/O module B2, port n. • Mezzanine card C will connect to I/O module C1, port n and I/O module C2, port n. For example, in a blade in slot 12, the integrated NIC will connect to I/O module A1, port 12 and I/O module A2, port 12. Table 1-13. Example of I/O Module Port Assignments - Half-Height Blade 1 Blade 1 I/O Module A1 B1 C1 C2 B2 Integrated LOM Port 1 Port 11 Mezzanine Card C Mezzanine Card B A2 Port 1 Port 1 Port 1 Port 1 Figure 1-17 shows the port connections for a half-height blade in bay 1 with two mezzanine cards. About Your System 51 Figure 1-17. Example of Half-Height Blade Port Mapping 52 About Your System Cisco SFS M7000e Infiniband Switch Module The Cisco SFS M7000e Infiniband switch module includes 24 4x DDR Infiniband ports. Eight ports are external uplink ports, and 16 internal ports provide connectivity to the blades in the enclosure. This switch module is hot-pluggable, and may be installed in Fabric B or Fabric C. For general information on installing this module, see "I/O Modules" on page 166. Figure 1-18. Cisco SFS M7000e Infiniband Switch Module Features 1 2 3 4 1 Infiniband ports (8) 2 port status indicator (8) 3 diagnostic status indicator 4 power indicator About Your System 53 Table 1-14. Cisco SFS M7000e Infiniband Switch Indicators Indicator Type Pattern Description Infiniband port status indicator Off Link error or Subnet Manager not operating Green flickering I/O activity on port Green on Link established Module status Off indicator Switch is not ready Blue on Switch operating normally Amber on or blinking Fault condition in module Module power Off indicator Green Power to the module is off Module has power PowerConnect M6220 Ethernet Switch Module The PowerConnect M6220 Ethernet switch module includes four external 10/100/1000 Mbps Ethernet connectors and one USB type A form factor serial connector. See Figure 1-19. Two option bays support the following three module options: • A resilient stacking module with 2 x 24 Gb stacking ports • A 10 Gb Ethernet module with two 10 Gb optical XFP connectors • A 10 Gb Ethernet module with two copper CX4 uplinks. Installing two option modules provides additional stacking and redundancy support. Sixteen internal Gb Ethernet connectors link to the blades in the enclosure. For additional information about the PowerConnect M6220 Ethernet switch module, see the documentation that shipped with the module. For general information on installing this module, see "I/O Modules" on page 166. 54 About Your System Figure 1-19. PowerConnect M6220 Ethernet Switch Module Features 1 2 3 4 5 1 optional module (2) (dual 10 Gb Ethernet uplink module shown) 2 standard 10/100/1000 Mb Ethernet connectors (4) 3 serial connector (USB type-A form factor) 4 power indicator 5 status/identification indicator Cisco Ethernet Switch Your system supports three Cisco Catalyst Blade Switch (CBS) versions: • The Cisco 3130G-S switch includes four 10/100/1000 Mb Ethernet uplink ports and two Stackwise Plus ports. About Your System 55 • The Cisco CBS 3130X-S switch includes four 10/100/1000 Mb Ethernet uplink ports, two 10 Gb uplink ports, and two Stackwise Plus ports. • The Cisco CBS 3032 switch includes four 10/100/1000 Mb Ethernet uplink ports. The two option bays support the following module options: • Cisco X2 10 Gb transceiver modules (CBS 3130X-S only) • Cisco TwinGig converter modules All three switches include a RJ-45 console connector for switch management. Sixteen internal Gb Ethernet connectors link to the blades in the enclosure. See Figure 1-19. For additional information about the Cisco CBS Ethernet switch modules, see the documentation that shipped with the module. For general information on installing this module, see "I/O Modules" on page 166. 56 About Your System Figure 1-20. Cisco Ethernet Switch Module Features 1 2 3 4 5 6 7 8 1 Stackwise Plus connectors (not enabled in CBS 3032) 2 10/100/1000 Mb Ethernet connectors (4) 3 option bays (2) 4 Cisco status indicators 5 mode button 6 console port for switch management 7 power indicator 8 status/identification indicator About Your System 57 Fibre Channel Pass-through Module The Fibre Channel pass-through module provides a bypass connection between a Fibre Channel mezzanine card in the blade and optical transceivers for direct connection into a Fibre Channel switch or a storage array (see Figure 1-21). The 16 pass-through ports on this module can negotiate speeds of 1-, 2-, or 4-Gbps. The Fibre Channel pass-through modules are hotpluggable, and may be installed in Fabric B or Fabric C. Table 1-15 and list the functionality of the indicators on each individual Fibre Channel connector. For general information on installing this module, see "I/O Modules" on page 166. NOTE: To ensure proper functionality, use only the Short Wave Small Form Factor Pluggable (SFP) transceivers provided with this module. 58 About Your System Figure 1-21. Fibre Channel Pass-through Module Features 1 2 3 4 1 SFP Fibre Channel connector (16) 2 Fibre Channel green/amber indicators (two per port) 3 power indicator 4 status/identification indicator About Your System 59 Table 1-15. Fibre Channel Pass-through Indicators Indicator Type Pattern Description Power indicator Off Power to the module is off Green Module has power. Status/ Blue on identification indicator Primary module in a stack, if applicable Blue off Secondary module in a stack Amber flashing Fault condition in module Fibre Channel port indicators with Emulex mezzanine card installed Green off, amber Mezzanine board failure before POST off Green off, amber Mezzanine board failure during POST on or green off, amber blinking Green off, amber POST in progress flashing irregularly Green on, amber Mezzanine board failure during operation off or green on, amber on Green on, one fast amber blink 1 Gb link established Green on, two 2 Gb link established fast amber blinks Green on, three 4 Gb link established fast amber blinks 60 Slow green blinking, amber off No link established Slow green blinking, slow amber blinking Offline for firmware download About Your System Table 1-15. Fibre Channel Pass-through Indicators (continued) Indicator Type Pattern Description Fibre Channel Port LEDs with Qlogic Mezzanine Card Installed Green off, amber Power off off Green off, amber Online, 1 Gb or 2 Gb link on Green on, amber Online, 4Gb link off Green off, amber I/O activity, 1 Gb or 2 Gb flashing Green flashing, amber off I/O activity, 4 Gb Green flashing and amber flashing at same time Loss of synchronization Green flashing Firmware error and amber flashing at different intervals Off/amber flashing (twice per second) Connection has lost synchronization. Brocade M4424 SAN I/O Module The Brocade M4424 SAN I/O module includes eight external autosensing Fibre Channel ports (four ports are enabled in the standard configuration and four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with an RJ-45 connector. The external Fibre Channel ports operate at 1 Gb/sec, 2 Gb/sec, or 4 Gb/sec. The Fibre Channel switch module is hot-pluggable, and may be installed in Fabric B or Fabric C. For general information on installing this module, see "I/O Modules" on page 166. About Your System 61 NOTE: The Fibre Channel switch module includes Short Wave Small Form Factor Pluggable (SFP) optical transceivers. To ensure proper functionality, use only SFPs provided with this module. Figure 1-22. Brocade M4424 SAN I/O Module Features 1 2 3 4 5 6 7 62 1 Fibre Channel port (8) 2 Fibre Channel port status indicator (8) 3 Fibre Channel port speed indicator (8) 4 serial port (RJ-45 connector) About Your System 5 module status indicator 7 status/identification indicator Table 1-16. 6 power indicator Brocade M4424 SAN I/O Module Indicators Indicator Type Pattern Description Fibre Channel Off port status Amber on indicator Green on No signal carrier Signal present but not online Online, but no activity Green blinking slowly Online but segmented Green blinking quickly Internal loopback Green flickering I/O activity on port Amber blinking slowly Port disabled Amber blinking rapidly Error or fault with port Fibre Channel Off port speed Green on indicator Amber on Module status Off indicator Green on 1 Gb link established 2 Gb link established 4 Gb link established Module is off or enclosure power is off. All ports are ready for use Amber on Module is booting being reset, or ports are offline Green/amber blinking Diagnostic message in error log, or environmental range exceeded Module power Off indicator Green Blue on Status/ identification Blue off indicator Amber flashing Power to the module is off Module has power. Primary module in a stack, if applicable Secondary module in a stack Fault condition in module About Your System 63 Ethernet Pass-through Module The Ethernet pass-through module supports 10/100/1000 Mb connections, and provides a direct connection between the optional internal Ethernet mezzanine card in the blade, and an external Ethernet device (see Figure 1-23). The Ethernet pass-through modules are hot-pluggable, and may be installed in any of the three Fabrics. Table 1-17 lists the functionality of the Ethernet pass-through module indicators. For additional information on installing this module, see "I/O Modules" on page 166. 64 About Your System Figure 1-23. Ethernet Pass-through Module Features 1 3 2 11 4 5 1 link indicator (16) 2 activity indicator (16) 3 RJ45 Ethernet connector (16) 4 power indicator 5 status/identification indicator NOTE: Connectors on the Ethernet pass-through module correspond directly to the blade number. For example, blade 5 is connected to port 5 on the Ethernet passthrough module. Integrated network adapter 1 will map to I/O slot A1. Integrated network adapter 2 will map to I/O slot A2. About Your System 65 Table 1-17. Ethernet Pass-through Module Indicators Indicator Type Pattern Description Link Green on, indicator/activity amber indicator blinking The Ethernet connector is linked to the blade and there is network activity. Green on, amber off The Ethernet connector is linked to the blade and there is no network activity. Green off, amber blinking The Ethernet connector is not linked to the blade and there is network activity. Green The Ethernet connector is not linked to the blade off/amber off and there is no network activity. Power indicator Status/ identification indicator Off Power to the module is off. Green Module has power. Blue on Active module. Amber flashing Fault condition in module. NOTE: Ethernet media speed is configured through the blade LOM firmware or by the operating system. Speed and duplex settings are not configured through the passthrough module itself. System Messages Table 1-18 lists the system messages that can occur and the probable cause and corrective action for each message. CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. NOTE: If you receive a system message that is not listed in Table 1-18, check the documentation for the application that is running when the message appears, or the operating system's documentation for an explanation of the message and recommended action. 66 About Your System Table 1-18. Blade Messages Message Causes Corrective Actions Alert: DIMM_n and The installed memory DIMM_n must be configuration is invalid. populated with a matched set of DIMMs if more than 1 DIMM is present. The following memory DIMMs have been disabled. Ensure that the memory modules are installed in matched pairs. See "System Memory" on page 105. Alert! Node The installed memory Interleaving configuration does not disabled! Memory support node interleaving. configuration does not support Node Interleaving. Install a memory configuration that supports node interleaving. See "System Memory" on page 105. Alert! Redundant memory disabled! Memory configuration does not support redundant memory. The installed memory configuration does not support redundant memory. Alert! Redundancy was previously lost. Power cycle required to reconfigure redundant memory. Memory error. Install a memory configuration that supports redundant memory. See "System Memory" on page 105. Disable the Redundant Memory option in the System Setup program. See "Using the System Setup Program" on page 79. Power cycle the blade. About Your System 67 Table 1-18. Blade Messages (continued) Message Causes Corrective Actions Alert! Unsupported The installed memory memory, incomplete configuration is invalid. sets, or unmatched sets. The following memory DIMMs have been disabled: Add, move, or remove memory modules to achieve a configuration supported by the system. See "System Memory" on page 105. Caution! NVRAM_CLR NVRAM_CLR jumper is jumper is set to "on." installed on system board. Set the NVRAM_CLR jumper to "off." See Figure 7-1, Figure 7-2, Figure 7-3 or Figure 7-4 for the jumper location. CPUs with different cache sizes detected. Mismatched processors are Install a correct version of installed. the microprocessor so that both microprocessors have the same cache size. See "Processors" on page 128. Decreasing available memory. Faulty or improperly Ensure that all memory installed memory modules. modules are properly installed. See "Troubleshooting Blade Memory" on page 191. DIMMs should be installed in pairs. Pairs must be matched in size, speed, and technology. Mismatched or unmatched DIMMs installed; faulty or improperly installed memory modules. The system will operate in a degraded mode with reduced ECC protection. Only memory installed in channel 0 will be accessible. 68 About Your System Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "System Memory" on page 105. If the problem persists, see "Troubleshooting Blade Memory" on page 191. Table 1-18. Blade Messages (continued) Message Causes Corrective Actions DIMMs must be populated in sequential order beginning with slot 1. The following DIMM is electrically isolated: DIMM x. The specified DIMM is Populate two, four, or eight inaccessible to the system DIMMs sequentially. due to its location. DIMMs must be populated in sequential order, beginning with slot 1. DIMM pairs must be matched in size, speed, and technology. The following DIMM pair is mismatched: DIMM x and DIMM y. Mismatched or unmatched DIMMs installed; faulty or improperly seated memory modules. Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. See "System Memory" on page 105. See "Troubleshooting Blade Memory" on page 191. Diskette read failure. Faulty or improperly inserted diskette. Replace the diskette. Drive not ready. Diskette missing or improperly inserted in diskette drive. Reinsert or replace the diskette. Error: Incorrect memory configuration. DIMMs must be installed in pairs of matched memory size, speed, and technology. Mismatched or unmatched DIMMs installed; faulty or improperly seated memory modules. Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. See "System Memory" on page 105. If the problem persists, see "Troubleshooting Blade Memory" on page 191. Error: Incorrect memory configuration. System halted. Less than 512 MB of memory installed. Add memory modules to achieve a configuration supported by the system. See "System Memory" on page 105. About Your System 69 Table 1-18. Blade Messages (continued) Message Causes Error: Memory Faulty or improperly failure detected. seated memory modules. Memory size reduced. Replace the faulty DIMM as soon as possible. Error programming flexAddress (MAC) for bus, device, function. Corrective Actions See "Troubleshooting Blade Memory" on page 191. FlexAddress (virtual Information only MAC) is not supported on the specified device. Error programming FlexAddress (virtual Information only flexAddress (iSCSI MAC) is not supported on the specified device. MAC) for bus, device, function. Error resetting NIC after programming flexAddress for bus, device, function. FlexAddress (virtual Information only MAC) is not supported on the specified device. FBD training error: The following branch has been disabled: Branch x. The specified branch (channel pair) contains DIMMs that are incompatible with each other. Gate A20 failure. Faulty keyboard controller See "Getting Help" on (faulty blade board). page 217. General failure. Operating system corrupted or improperly installed. 70 About Your System Ensure that only Dell qualified memory is used. Dell recommends purchasing memory upgrade kits directly from http://www.dell.com or your Dell sales agent to ensure compatibility. Reinstall the operating system. Table 1-18. Blade Messages (continued) Message Causes Corrective Actions HyperTransport error caused a system reset. Please check the system event log for details. HyperTransport error. See "Getting Help" on page 217. Invalid flexAddress for bus, device, function. FlexAddress (virtual Information only MAC) is not supported on the specified device. Keyboard controller failure. Faulty keyboard controller See "Getting Help" on (faulty blade board). page 217. Keyboard failure. Loose or improperly Ensure that the keyboard is connected keyboard cable properly connected. If the problem persists, replace the keyboard. Manufacturing mode System is incorrectly detected. configured. Set the NVRAM_CLR jumper to "on" and reboot the blade. See Figure 7-1, Figure 7-2, Figure 7-3 or Figure 7-4 for the jumper location. About Your System 71 Table 1-18. Blade Messages (continued) Message Causes Corrective Actions Faulty or improperly Ensure that all memory installed memory modules, modules are properly or faulty blade board. installed. See "Troubleshooting Blade Memory" on page 191. If the problem persists, see Memory double word "Getting Help" on page 217. logic failure at address, read value expecting value. Memory address line failure at address, read value expecting value. Memory odd/even logic failure at start address to end address. Memory write/read failure at address, read value expecting value. Memory mirroring enabled. Memory mirroring enabled Information only. Memory tests terminated by keystroke. The spacebar or ESC key was pressed during POST to terminate the memory test. Information only. 72 About Your System Table 1-18. Blade Messages (continued) Message Causes Corrective Actions No boot device available. Faulty or missing diskette Check the Integrated drive, optical drive, or hard Devices configuration drive. settings in the System Setup program and ensure that the controller for the boot device is enabled. See "Using the System Setup Program" on page 79. Ensure that the controller for the boot device is enabled. If the problem persists, replace the drive. See "Hard Drives" on page 142. No boot sector on hard-disk drive. An operating system is not Check the hard-drive on the hard drive. configuration settings in the System Setup program. See "Using the System Setup Program" on page 79. No timer tick interrupt. Faulty blade board. See "Getting Help" on page 217. Not a boot diskette. Not a bootable diskette. Use a bootable diskette. PCI BIOS failed to Faulty or improperly install. installed mezzanine card. Plug & Play Configuration Error. Error encountered in initializing PCI device; faulty blade board. Reseat the mezzanine card. See "I/O Module Mezzanine Cards" on page 123. If the problem persists, see "Getting Help" on page 217. Set the NVRAM_CLR jumper to "on" and reboot the blade. See Figure 7-1, Figure 7-2, Figure 7-3 or Figure 7-4 for the jumper location. Check for a BIOS update. If the problem persists, see "Getting Help" on page 217. About Your System 73 Table 1-18. Blade Messages (continued) Message Causes Corrective Actions Read fault. Faulty diskette, diskette drive, or optical drive. Replace the diskette. Ensure that the drive cable is properly connected. See "Troubleshooting USB Devices" on page 183 or "Troubleshooting Hard Drives" on page 192 for the appropriate drive(s) installed in your system. Remote Configuration update attempt failed. Blade could not implement Remote Configuration request. Retry Remote Configuration. Sector not found. Faulty diskette or hard drive. Replace the diskette. If the problem persists, see "Troubleshooting Hard Drives" on page 192 for the appropriate drive installed in your system. Shutdown failure. Shutdown test failure. Ensure that all memory modules are properly installed. See "Troubleshooting Blade Memory" on page 191. If the problem persists, see "Getting Help" on page 217. Spare bank enabled. Memory sparing enabled. Information only. The amount of system memory has changed. Faulty memory module. See "Troubleshooting Blade Memory" on page 191. If the problem persists, see "Getting Help" on page 217. Seek error. Seek operation failed. Information only, if you have changed the memory configuration. 74 About Your System Table 1-18. Blade Messages (continued) Message Causes Corrective Actions This system does Unsupported processor(s) not support installed. processors greater than 95W. Replace the processor(s) with a supported version. See "Processors" on page 128. This system only Unsupported processor(s) supports Opteron installed. 2000 series processors. System halted. Replace the processor(s) with a supported version. See "Processors" on page 128. Time-of-day clock stopped. Faulty battery; faulty blade See "Troubleshooting Blade board. Memory" on page 191. If the problem persists, see "Getting Help" on page 217. Time-of-day not set — please run SETUP program. Incorrect Time or Date Check the Time and Date settings; faulty blade board settings. See "Using the battery. System Setup Program" on page 79. If the problem persists, see "Troubleshooting the NVRAM Backup Battery" on page 195. Timer chip counter Faulty blade board. 2 failed. See "Getting Help" on page 217. See "Getting Help" on page 217. TPM failure A Trusted Platform Module (TPM) function has failed. Unsupported CPU combination. Mismatched processors are Replace a microprocessor so installed. that both microprocessors Processor is not supported match. See "Processors" on page 128. by the blade. Check for a BIOS update using the Dell Support website at support.dell.com. About Your System 75 Table 1-18. Blade Messages (continued) Message Causes Corrective Actions Unsupported CPU Processor is not supported Check for a BIOS update stepping detected. by the blade. using the Dell Support website at support.dell.com. If the problem persists, install a supported processor. See "Processors" on page 128. Warning! A fatal error has caused system reset. Please check the event log for details. Unspecified error. Warning! Following Faulty or improperly seated memory modules. faulty DIMMs are disabled: DIMMxx, DIMMyy. Check the system event log for information about the error. See "Troubleshooting Blade Memory" on page 191. Warning! No microcode update loaded for processor n. Unsupported processor. Warning: The current memory configuration is not validated. Change it to the recommended memory configuration or press any key to continue. There is no memory See "System Memory" on configuration error, but page 105. the memory configuration is not recommended by Dell. 76 About Your System Update the BIOS firmware using the Dell Support website at support.dell.com. Table 1-18. Blade Messages (continued) Message Causes Warning: The current memory configuration is not optimal. For more information on valid memory configurations, please see the Hardware Owner’ Manual on the technical support site. See "System Memory" on There is no memory configuration error, but page 105. the memory configuration is not recommended by Dell. Write fault. Faulty diskette, diskette drive, or optical drive. Write fault on selected drive. Corrective Actions Replace the diskette. Ensure that the drive cable is properly connected. See "Troubleshooting USB Devices" on page 183 or "Troubleshooting Hard Drives" on page 192 for the appropriate drive(s) installed in your system. Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no). NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application. About Your System 77 Diagnostics Messages When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help" on page 217, then follow the instructions in that section for obtaining technical assistance. Alert Messages Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation. 78 About Your System Using the System Setup Program After you set up your system, run the System Setup program to familiarize yourself with your system configuration and optional settings. Record the information for future reference. You can use the System Setup program to: • Change the system configuration stored in NVRAM after you add, change, or remove hardware • Set or change user-selectable options—for example, the time or date • Enable or disable integrated devices • Correct discrepancies between the installed hardware and configuration settings NOTE: When a blade is inserted into an enclosure, the blade functions as a system. Each blade has a System Setup program to allow configuration of the blade and features such as password protection. Entering the System Setup Program 1 Turn on or restart the blade. 2 Press <F2> immediately after you see the following message: <F2> = Setup If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again. NOTE: To ensure an orderly system shutdown, see the documentation that accompanied your operating system. Responding to Error Messages You can enter the System Setup program by responding to certain error messages. If an error message appears while the system is booting, make a note of the message. Before entering the System Setup program, see "System Messages" on page 66 and "Warning Messages" on page 77 for an explanation of the message and suggestions for correcting errors. Using the System Setup Program 79 NOTE: After installing a memory upgrade, it is normal for your system to send a message the first time you start your system. Using the System Setup Program Table 2-1 lists the keys that you use to view or change information on the System Setup program screens and to exit the program. Table 2-1. System Setup Program Navigation Keys Keys Action Up arrow or <Shift><Tab> Moves to the previous field. Down arrow or <Tab> Moves to the next field. Spacebar, <+>, <–>, left and right arrows Cycles through the settings in a field. In some fields, you can also type the appropriate value. <Esc> Exits the System Setup program and restarts the system if any changes were made. <F1> Displays the System Setup program's help file. NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system. System Setup Options Main Screen When you enter the System Setup program, the main System Setup program screen appears (see Figure 2-1). 80 Using the System Setup Program Figure 2-1. Main System Setup Program Screen Table 2-2 lists the options and descriptions for the information fields that appear on the main System Setup program screen. NOTE: The options for the System Setup program change based on the system configuration. NOTE: The System Setup program defaults are listed under their respective options, where applicable. Table 2-2. System Setup Program Options Option Description Asset Tag Displays the customer-programmable asset tag number for the system if an asset tag number has been assigned. To enter an asset tag number of up to 10 characters into NVRAM, see "Acquiring the asset.com Utility" on page 94. System Time Resets the time on the system's internal clock. System Date Resets the date on the system's internal calendar. Memory Information See "Memory Information Screen" on page 83. CPU Information See "CPU Information Screen" on page 84. Using the System Setup Program 81 Table 2-2. System Setup Program Options (continued) Option Description Boot Sequence Determines the order of devices from which the system attempts to boot during system startup. Available options can include a USB diskette drive, USB DVD/CD drive, hard drives, and USB flash drive. NOTE: The USB diskette and DVD/CD-ROM device will be displayed in the boot order setup screen even if they are not attached to the system before you run the System Setup program Hard-Disk Drive Sequence Determines the order in which the BIOS will attempt to boot from hard drives in the system during system startup. USB Flash Drive Emulation Type (Auto default) Determines the emulation type for a USB flash drive. Hard disk allows the USB flash drive to act as a hard drive. Floppy allows the USB flash drive to act as a removable diskette drive. Auto automatically chooses an emulation type. Auto automatically chooses the appropriate emulation type for the device, except for devices installed in the SD card slot. A device installed in the SD card slot will automatically emulate a hard drive. If you install a device in this slot that is configured as a removable diskette drive, you must manually set the emulation type to Floppy. Boot Sequence Retry If this field is enabled and the system has failed to boot, the (Disabled default) system will reattempt to boot after 30 seconds. Integrated Devices See "Integrated Devices Screen" on page 85. PCI IRQ Assignment Displays a screen to change the IRQ assigned to each of the integrated devices on the PCI bus, and any installed expansion cards that require an IRQ. Serial Communication See "Serial Communication Screen" on page 86. System Security Displays a screen to configure the system password and setup password features. See "Using the System Password" on page 90 and "Using the Setup Password" on page 93 for more information. Keyboard NumLock (On default) Determines whether your system starts up with the NumLock mode activated on 101- or 102-key keyboards (does not apply to 84-key keyboards). 82 Using the System Setup Program Table 2-2. System Setup Program Options (continued) Option Description Report Keyboard Errors (Report default) Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached. Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST. This setting does not affect the operation of the keyboard itself if a keyboard is attached to the system. Memory Information Screen Table 2-3 lists the options and descriptions for the information fields that appear on the Memory Information screen. Table 2-3. Memory Information Screen Option Description System Memory Size Displays the amount of main memory. (If memory mirroring or spare memory is enabled, this value will be less than the amount of physical memory installed in the blade.) This field does not have user-selectable settings. System Memory Type Displays the type of system memory. This field does not have user-selectable settings. System Memory Speed Displays the system memory clock frequency. This field does not have user-selectable settings. Video Memory Displays the amount of video memory. This field does not have user-selectable settings. System Memory Testing Determines if memory is being tested during POST. Setting (Enabled default) this value to Enabled will affect the duration of system POST. Node Interleaving (Disabled default) If set to Disabled (default), NUMA is employed. If Enabled, memory interleaving is implemented. Memory Optimizer (PowerEdge M905, M805, M605. Enabled default) If set to Disabled, the two DRAM controllers operate in 128-bit mode, and memory reliability is enhanced. If set to Enabled, the memory controllers operate independently in 64-bit mode, and memory performance is optimized. Using the System Setup Program 83 Table 2-3. Memory Information Screen (continued) Option Description Redundant Memory (PowerEdge M600) If a valid memory configuration is installed, you can enable memory mirroring or spare memory. Options are Mirror Mode, Spare Mode, and Disabled. See "System Memory" on page 105. Redundant Memory (PowerEdge M905, M805, M605) If a valid memory configuration is installed, you can enable spare memory. Options are Spare Mode, and Disabled. See "System Memory" on page 105. Low Power Mode (Disabled default) If set to Disabled, memory runs at full speed. If set to Enabled, memory runs at reduced speed to conserve power. CPU Information Screen Table 2-4 lists the options and descriptions for the information fields that appear on the CPU Information screen. Table 2-4. CPU Information Screen Option Description 64-bit Displays the processor register width. Core Speed Displays the core speed of the processors. Bus Speed Displays the bus speed of the processors. Virtualization Technology (Disabled default) NOTE: Disable this feature if your system will not be running Adjacent Cache Line Prefetch (PowerEdge M600. Enabled default) Enables or disables optimal use of sequential memory access. Enabled optimizes the system for applications that require sequential memory access. Disabled is used for applications with random memory access. Hardware Prefetcher (Enabled default) Enables or disables the hardware prefetcher. 84 virtualization software. Displays when the processors support Virtualization Technology. Enabled permits virtualization software to use Virtualization Technology incorporated in the processor design. This feature can only be used by software that supports Virtualization Technology. Using the System Setup Program Table 2-4. CPU Information Screen (continued) Option Description Demand-Based Power Management (Enabled default) Enables or disables demand-based power management. When enabled, the CPU Performance State tables will be reported to the operating system; when disabled, the CPU Performance State tables will not be reported to the operating system. If any of the CPUs do not support demand-based power management, the field will become read-only and is automatically set to Disabled. Processor X ID Displays the family and model number of each processor. A submenu displays the core speed, the amount of cache memory, and the number of cores of the processor(s) Integrated Devices Screen Table 2-5 lists the options and descriptions for the information fields that appear on the Integrated Devices screen. Table 2-5. Integrated Devices Screen Options Option Description Integrated SAS Controller or Integrated RAID controller (Enabled default.) Enables the integrated SAS or RAID controller. User Accessible USB Ports (All Ports On default) Enables or disables the system's USB ports. Options are All Ports On or All Ports Off. SD Card Port (PowerEdge M905 and M805) Enables or disables the system’s internal SD card port. Embedded Gb NICx (Enabled with PXE default) Enables or disables the system's integrated NICs. Options are Enabled, Enabled with PXE, Enabled with iSCSI Boot, and Disabled. PXE support allows the system to boot from the network. Changes take effect after the system reboots. NOTE: This port is dedicated to a hypervisor, if installed. Using the System Setup Program 85 Table 2-5. Integrated Devices Screen Options (continued) Option Description MAC Address Displays the MAC address for a particular integrated NIC. This field does not have user-selectable settings. Capability Detected Displays the features provided by the hardware key installed in the TOE_KEY socket on the system board. NOTE: Some features may require the installation of an additional driver. OS Watchdog Timer (Disabled default). If set to Enabled, the operating system will restart the system if it locks up, based on the expiration of a timer. If set to Disabled, in the event of a system lockup, no timer will be set and the OS will not restart the system in the event of a lockup. I/OAT DMA Engine If set to Enabled, the I/O Acceleration Technology feature (PowerEdge M600 only. is enabled for network controllers that support this Disabled default). technology. Serial Communication Screen The blade has a single serial port (COM1) which can be enabled for console redirection through the IMC. Table 2-6 lists the options and descriptions for the information fields that appear on the Serial Communication screen. Table 2-6. Serial Communication Screen Options Option Description Serial Communication (Off default) Options are On with Console Redirection via COM1, and Off. Failsafe Baud Rate (115200 default) Displays the failsafe baud rate used for console redirection when the baud rate cannot be negotiated automatically with the remote terminal. Remote Terminal Type (VT 100/VT 220 default) Select either VT 100/VT 220 or ANSI. Redirection After Boot (Enabled default) Enables or disables BIOS console redirection after your system boots to the operating system. 86 Using the System Setup Program Embedded Server Management Screen Table 2-7 lists the options and descriptions for the information fields that appear on the Embedded Server Management screen. Table 2-7. Embedded Server Management Screen Options Option Description Front Panel LCD Options (Default default Options are User Defined LCD String, Default (the system model name and number), or None Use-Defined LCD String You can enter a name or other identifier for the system, to be displayed on the LCD module screen. System Security Screen Table 2-8 lists the options and descriptions for the information fields that appear on the System Security screen. Table 2-8. System Security Screen Options Option Description System Password Displays the current status of your system’s password security feature and allows you to assign and verify a new password. NOTE: See "Using the System Password" on page 90 for instructions on assigning a password and using or changing an existing blade password. Setup Password Restricts access to the System Setup program in the same way that you restrict access to your system using the System Password feature. NOTE: See "Using the System Password" on page 90 for instructions on assigning a setup password and using or changing an existing setup password. Using the System Setup Program 87 Table 2-8. System Security Screen Options (continued) Option Description Password Status Setting the Setup Password option to Enabled prevents the system password from being changed or disabled at start-up. To lock the system password, assign a setup password in the Setup Password option and then change the Password Status option to Locked. In this state, you cannot change the system password using the System Password option and the system password cannot be disabled at start-up by pressing <Ctrl><Enter>. To unlock the system password, enter the setup password in the Setup Password field and then change the Password Status option to Unlocked. In this state, you can disable the system password at start-up by pressing <Ctrl><Enter> and then change the password using the System Password option. TPM Security (PowerEdge M905 M805, and M605. Off is default) Sets the reporting of the Trusted Platform Module (TPM) in the system. When set to Off, presence of the TPM is not reported to the operating system. When set to On with Pre-boot Measurements, the system reports the TPM to the operating system and stores the pre-boot measurements (compliant with Trusted Computing Group standards) to the TPM during POST. When set to On without Pre-boot Measurements, the system reports the TPM to the operating system and bypasses pre-boot measurements. TPM Activation (PowerEdge M905 M805, and M605. No Change is default) Changes the operational state of the TPM. When set to Activate, the TPM is enabled and activated at default settings. When set to Deactivate, the TPM is disabled and deactivated. The No Change state initiates no action. The operational state of the TPM remains unchanged (all user settings for the TPM are preserved). NOTE: This field is read-only when TPM Security is set to Off. 88 Using the System Setup Program Table 2-8. System Security Screen Options (continued) Option Description NOTICE: Clearing the TPM will cause loss of all encryption keys in the TPM. This option will prevent booting to the operating system and will result in loss of data if the encryption keys cannot be restored. Be sure to back up the TPM keys prior to enabling this option. TPM Clear (M905 M805, and M605 No is default) When set to Yes, all the contents of the TPM are cleared. NOTE: This field is read-only when TPM Security is set to Off. Power Button Enables or disables the blade’s power button. • If you turn off the blade using the power button and you are using an ACPI-compliant operating system, the blade can perform an orderly shutdown before power is turned off. • If the blade is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed. The button is enabled in the System Setup program. When disabled, the button can only turn on blade power. AC Power Recovery (Last is default) Determines how the blade reacts when power is restored. If the option is set to Last, the blade returns to the last power state. On turns on the blade after power is restored. When set to Off, the blade remains off after power is restored. Exit Screen After you press <Esc> to exit the System Setup program, the Exit screen displays the following options: • Save Changes and Exit • Discard Changes and Exit • Return to Setup Using the System Setup Program 89 System and Setup Password Features NOTICE: The password features provide a basic level of security for the data on your system. If your data requires more security, use additional forms of protection, such as data encryption programs. NOTICE: Anyone can access the data stored on your system if you leave the system running and unattended without having a system password assigned or if you leave your system unlocked so that someone can disable the password by changing a jumper setting. Your system is shipped to you without the system password feature enabled. If system security is a concern, operate your system only with system password protection. To change or delete an existing password, you must know the password (see "Deleting or Changing an Existing System Password" on page 92). If you forget your password, you cannot operate your system or change settings in the System Setup program until a trained service technician changes the password jumper setting to disable the passwords, and erases the existing passwords. See "Disabling a Forgotten Password" on page 214. Using the System Password After a system password is assigned, only those who know the password have full use of the system. When the System Password option is set to Enabled, the system prompts you for the system password after the system starts. Assigning a System Password Before you assign a system password, enter the System Setup program and check the System Password option. When a system password is assigned, the setting shown for the System Password option is Enabled. If the setting shown for the Password Status is Unlocked, you can change the system password. If the Password Status option is Locked, you cannot change the system password. When the system password feature is disabled by a jumper setting, the system password is Disabled, and you cannot change or enter a new system password. 90 Using the System Setup Program When a system password is not assigned and the password jumper on the system board is in the enabled (default) position, the setting shown for the System Password option is Not Enabled and the Password Status field is Unlocked. To assign a system password: 1 Verify that the Password Status option is set to Unlocked. 2 Highlight the System Password option and press <Enter>. 3 Type your new system password. You can use up to 32 characters in your password. As you press each character key (or the spacebar for a blank space), a placeholder appears in the field. The password assignment is not case-sensitive. However, certain key combinations are not valid. To erase a character when entering your password, press <Backspace> or the left-arrow key. NOTE: To escape from the field without assigning a system password, press <Enter> to move to another field, or press <Esc> at any time prior to completing step 5. 4 Press <Enter>. 5 To confirm your password, type it a second time and press <Enter>. The setting shown for the System Password changes to Enabled. Exit the System Setup program and begin using your system. 6 Either reboot your system now for your password protection to take effect or continue working. NOTE: Password protection does not take effect until you reboot the system. Using Your System Password to Secure Your System NOTE: If you have assigned a setup password (see "Using the Setup Password" on page 93), the system accepts your setup password as an alternate system password. When the Password Status option is set to Unlocked, you have the option to leave the password security enabled or to disable the password security. Using the System Setup Program 91 To leave the password security enabled: 1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>. 2 Press <Enter>. 3 Type your password and press <Enter>. To disable the password security: 1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>. 2 Press <Ctrl><Enter>. When the Password Status option is set to Locked whenever you turn on your system or reboot your system by pressing <Ctrl><Alt><Del>, type your password and press <Enter> at the prompt. After you type the correct system password and press <Enter>, your system operates as usual. If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message showing the number of unsuccessful attempts and that the system has halted and will shut down. This message can alert you to an unauthorized person attempting to use your system. Even after you shut down and restart the system, the error message continues to be displayed until the correct password is entered. NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password options to further protect your system from unauthorized changes. Deleting or Changing an Existing System Password 1 When prompted, press <Ctrl><Enter> to disable the existing system password. If you are asked to enter your setup password, contact your network administrator. 2 Enter the System Setup program by pressing <F2> during POST. 3 Select the System Security screen field to verify that the Password Status option is set to Unlocked. 4 When prompted, type the system password. 92 Using the System Setup Program 5 Confirm that Not Enabled is displayed for the System Password option. If Not Enabled is displayed for the System Password option, the system password has been deleted. If Enabled is displayed for the System Password option, press the <Alt><b> key combination to restart the system, and then repeat steps 2 through 5. Using the Setup Password Assigning a Setup Password You can assign (or change) a setup password only when the Setup Password option is set to Not Enabled. To assign a setup password, highlight the Setup Password option and press the <+> or <–> key. The system prompts you to enter and verify the password. NOTE: The setup password can be the same as the system password. If the two passwords are different, the setup password can be used as an alternate system password. However, the system password cannot be used in place of the setup password. You can use up to 32 characters in your password. As you press each character key (or the spacebar for a blank space), a placeholder appears in the field. The password assignment is not case-sensitive. However, certain key combinations are not valid. To erase a character when entering your password, press <Backspace> or the left-arrow key. After you verify the password, the Setup Password setting changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password. A change to the Setup Password option becomes effective immediately (restarting the system is not required). Operating With a Setup Password Enabled If Setup Password is set to Enabled, you must enter the correct setup password before you can modify most of the System Setup options. When you start the System Setup program, the program prompts you to enter a password. Using the System Setup Program 93 If you do not enter the correct password in three attempts, the system lets you view, but not modify, the System Setup screens—with the following exception: If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password (however, you cannot disable or change an existing system password). NOTE: You can use the Password Status option in conjunction with the Setup Password option to protect the system password from unauthorized changes. Deleting or Changing an Existing Setup Password 1 Enter the System Setup program and select the System Security option. 2 Highlight the Setup Password option, press <Enter> to access the setup password window, and press <Enter> twice to clear the existing setup password. The setting changes to Not Enabled. 3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 93. Disabling a Forgotten Password See "Disabling a Forgotten Password" on page 214. Acquiring the asset.com Utility The asset.com utility is not located in the Service Mode section of the Dell OpenManage Server Assistant CD. To acquire this utility, use the Server Assistant CD to create a bootable diskette; the utility is then automatically created on that diskette. The asset.com utility will be available in the Service Mode section in future releases of the Server Assistant CD. 94 Using the System Setup Program Installing Blade Components The procedures in this section describe how to remove and install components in a blade, including: • Memory modules • I/O module mezzanine cards • NIC TOE and iSCSI activation key • Processors • Hypertransport (HT) bridge card (service only) • Blade system board NVRAM backup battery (CMOS battery) • Hard drives • Video controller daughter card or riser card • Hard-drive backplane • System board (service only) • Storage controller card (service only) Installing Blade Components 95 Removing and Installing a Blade Removing a Blade 1 Power down the blade using OS commands or the CMC, and ensure that the blade's power is off. When a blade is powered off, its front-panel power indicator is off. See Figure 1-6. 2 Before removing full-height blades 1 or 2 or half-height blades 12 or 13, rotate the LCD panel to the storage position to prevent accidental damage to the LCD screen. 3 Press in the release button on the handle. See Figure 3-1 or Figure 3-2. 4 Pull out the handle to unlock the blade from the enclosure. 5 Slide the blade out of the enclosure. 6 Install the I/O connector cover over the I/O connector. NOTICE: To protect the I/O connector pins, install the I/O connector cover any time a blade is removed from the enclosure. (A full-height blade requires two connector covers.) NOTICE: If you are permanently removing the blade, install a blade blank. (A fullheight blade requires two blade blanks.) Operating the system for extended periods of time without a blade blank installed can cause the system to overheat. See "Removing and Installing a Blade Blank" on page 99. 96 Installing Blade Components Figure 3-1. Removing and Installing a Half-Height Blade 3 2 1 4 5 1 blade handle 2 release button 3 blade 4 guide rail on M1000e enclosure 5 guide rail on blade (or blade blank) Installing Blade Components 97 Figure 3-2. Removing and Installing a Full-Height Blade 3 2 1 4 5 1 blade handle 2 release button 3 blade 4 guide rail on M1000e enclosure 5 guide rail on blade Installing a Blade 1 If you are installing a new blade, remove the plastic cover from the I/O connector(s) and save for future use. See Figure 3-3. 2 Orient the blade so that the handle is on the left side of the blade. 98 Installing Blade Components 3 If you are installing a blade in one of the eight upper bays, align the guide rail on the upper edge of the blade so that the rail fits between the plastic guides on the enclosure. If you are installing a half-height blade in one of the eight lower bays, align the edge of the blade with the guide rail on the floor of the M1000e enclosure. If you are installing a full-height blade in bays 1 or 2 or a half-height blade in bays 12 or 13, rotate the LCD module to the horizontal storage position to prevent accidental damage to the LCD screen. 4 Slide the blade into the enclosure until the handle engages and locks the blade in place. Removing and Installing a Blade Blank NOTICE: If you are permanently removing a blade, install a blade blank. Operating the system for extended periods of time without a full complement of blades or blade blanks can cause the system to overheat. Removing a Blade Blank If you are removing a blade blank from one of the eight upper bays, press the blue latch at the upper edge of the blank faceplate and slide the blank out of the enclosure. If you are removing a blade blank from one of the eight lower bays, press the blue latch at the lower edge of the blank faceplate, and slide the blank out of the enclosure. Installing a Blade Blank 1 Hold the blank with the guide rail facing upwards (see detail in Figure 3-1). 2 Install the blank in the enclosure: • If you are installing a blade blank in one of the eight upper bays, align the metal guide rail on the upper edge of the blade blank so that the guide rail fits between the plastic guides on the enclosure (see detail in Figure 3-1). Installing Blade Components 99 • If you are installing a blade blank in one of the eight lower bays, align the edge of the blank with the plastic guide rail on the floor of the M1000e enclosure, and slide the blank into the enclosure until the lower latch engages. Opening and Closing the Blade Opening the Blade CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Remove the blade from the enclosure. See "Removing a Blade" on page 96. 2 Install the I/O connector cover (s). See Figure 3-3. A full-height blade requires two connector covers. 3 Orient the blade as shown in Figure 3-3 so that the cover-release latch faces up. 4 Lift the cover-release latch and slide the cover toward the back of the blade until it stops. 5 Carefully lift the cover away from the blade. 100 Installing Blade Components Figure 3-3. Opening a Blade (PowerEdge M600 Shown) 1 2 3 1 cover-release latch 3 I/O connector cover 2 chassis cover Installing Blade Components 101 Figure 3-4, Figure 3-5 and Figure 3-6 show the interior components in the blades. Figure 3-4. Inside a Half-Height Blade (PowerEdge M600 Shown) 3 2 1 4 5 6 10 7 9 8 102 1 optional Fabric C mezzanine card 2 optional Fabric B mezzanine card 3 memory modules 4 processor CPU1 and heat sink 5 hard-drive backplane 6 storage controller card (under drive bays) 7 hard drive 1 8 hard drive 0 9 processor CPU2 and heat sink 10 video riser card Installing Blade Components Figure 3-5. Inside a Full-Height Blade (PowerEdge M905 Shown) 4 5 6 3 7 2 1 8 14 13 12 9 11 10 1 optional mezzanine card 1 Fabric C 2 optional mezzanine card 2 Fabric B 3 optional mezzanine card 3 Fabric C 4 optional mezzanine card 4 Fabric B 5 SD card location 6 memory modules 7 processor CPU2 and heat sink 8 processor CPU4 and heat sink 9 hard drive 1 10 hard drive 0 11 hard-drive backplane 12 processor CPU3 and heat sink 13 processor CPU1 and heat sink 14 video riser card Installing Blade Components 103 Figure 3-6. Inside a Full-Height Blade (PowerEdge M805 Shown) 4 5 6 3 7 2 1 12 11 8 10 9 1 optional mezzanine card 1 Fabric C 2 optional mezzanine card 2 Fabric B 3 optional mezzanine card 3 Fabric C 4 optional mezzanine card 4 Fabric B 5 SD card location 6 processor CPU2 and heat sink 7 processor CPU2 and heat sink 8 hard drive 1 9 hard drive 0 10 hard-drive backplane 11 processor CPU1 and heat sink 12 video riser card Closing the Blade CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Ensure that no tools or parts are left inside the blade. 2 Align the notches in the edges of the enclosure with the cover alignment pins on the inner sides of the cover. 104 Installing Blade Components 3 Check that these cover-release latch is fully open, and lower the cover onto the enclosure. 4 Close the cover-release latch until it is flush with the surface of the cover. System Memory System Memory - PowerEdge M905 You can upgrade your system memory to a maximum of 192 GB by installing up to twenty-four 667-MHz registered DDR2 memory modules in sets of 1-GB, 2-GB, 4-GB, or 8-GB memory modules. (Dual-rank 8-GB modules are supported; quad-rank 8-GB modules are not supported.) Each processor has four memory channels, organized in sets of two channels. NOTICE: If more than four memory modules are installed per processor, the memory modules will be downclocked to operate at 533 Mhz. Installing Blade Components 105 Figure 3-7. Memory Locations - PowerEdge M905 B1 D1 D2 D3 D4 B8 C1 C2 C3 C4 A8 A1 General Memory Module Installation Guidelines - PowerEdge M905 To ensure optimal performance of your system, observe the following guidelines when configuring your system memory. 106 • Memory modules must be installed in pairs, beginning with the first two sockets in each set of memory modules. These sockets are marked by white retention levers. • All memory modules in the blade must be identical in speed and technology. The memory modules in each pair must be the same size. Installing Blade Components • If pairs of memory modules of different sizes are installed, the larger capacity memory modules must be installed in the lower numbered slots. • Memory sparing is supported if eight or 16 memory modules are installed. (Memory mirroring is not supported.) Table 3-1 shows examples of supported memory configurations. NOTICE: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. Table 3-1. Examples of PowerEdge M905 Memory Configurations Total System Memory Memory Modules Number and Size Memory Module Locations 8 GB Eight 1 GB A1, A2, B1, B2, C1, C2, D1, D2 16 GB Sixteen 1 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 16 GB Eight 2 GB A1, A2, B1, B2, C1, C2, D1, D2 32 GB Eight 4 GB A1, A2, B1, B2, C1, C2, D1, D2 32 GB Sixteen 2 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 48 GB Twenty-four 2 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4, D1, D2, D3, D4 64 GB* Eight 8 GB A1, A2, B1, B2, C1, C2, D1, D2 64 GB* Sixteen 4 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 96 GB Twenty-four 4 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4, D1, D2, D3, D4 128 GB Sixteen 8 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 192 GB Twenty-four 8 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4, D1, D2, D3, D4 *If 64 GB of memory is installed, the system will only recognize 63.75 GB during POST. Installing Blade Components 107 Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during startup stating that your memory configuration is nonoptimal. Memory Sparing Support - PowerEdge M905 Memory sparing (spare bank) is supported in systems that have one of the memory configurations shown in Table 3-2. The memory sparing feature must also be enabled in the Memory Information screen of the System Setup program. See "Memory Information Screen" on page 83. To use memory sparing, you must disable node interleaving. Table 3-2. Memory Sparing Configurations - PowerEdge M905 Total System Memory Usable System Memory Memory Modules Number and Size Memory Module Locations 16 GB 12 GB Eight 2 GB A1, A2, B1, B2, C1, C2, D1, D2 32 GB 28 GB Sixteen 2 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 64 GB 56 GB Sixteen 4 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 128 GB 112 GB Sixteen 8 GB A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3, C4, D1, D2, D3, D4 System Memory - PowerEdge M805 You can upgrade your system memory to a maximum of 128 GB by installing 667-MHz registered DDR2 memory modules in sets of 1-GB, 2-GB, 4-GB, or 8-GB memory modules. (Dual-rank 8-GB modules are supported; quad-rank 8-GB modules are not supported.) Each processor has four memory channels, organized in sets of two channels. NOTICE: If more than four memory modules are installed per processor, the memory modules will be downclocked to operate at 533 Mhz. 108 Installing Blade Components Figure 3-8. Memory Locations - PowerEdge M805 B1 B8 A8 A1 General Memory Module Installation Guidelines - PowerEdge M805 To ensure optimal performance of your system, observe the following guidelines when installing your system memory. • Memory modules must be installed in pairs of identically-sized DIMMs, beginning with slots A1 and A2 (processor 1) and B1 and B2. These slots are marked by white ejector tabs. • All memory modules in the blade must be identical in speed and technology. The memory modules in each pair must be the same size. Installing Blade Components 109 • Memory must be installed in the same configuration (symmetrically) for both processors. • If pairs of memory modules of different sizes are installed, the larger capacity memory modules must be installed in the lower numbered slots. • Memory sparing is supported if eight or sixteen memory modules are installed. (Memory mirroring is not supported.) Table 3-3 shows examples of supported memory configurations. NOTICE: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. Table 3-3. Examples of PowerEdge M805 Memory Configurations Total System Memory Memory Modules Number and Size Memory Module Locations 4 GB Four 1 GB A1, A2, B1, B2 8 GB Eight 1 GB A1, A2, A3, A4, B1, B2, B3, B4 8 GB Four 2 GB A1, A2, B1, B2 12 GB Twelve 2 GB A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6 16 GB Sixteen 1 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 16 GB Eight 2 GB A1, A2, A3, A4, B1, B2, B3, B4 16 GB Four 4 GB A1, A2, B1, B2 24 GB Twelve 2 GB A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6 32 GB Sixteen 2 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 32 GB Eight 4 GB A1, A2, A3, A4, B1, B2, B3, B4 48 GB Twelve 4 GB A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6 64 GB* Sixteen 4 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 64 GB* Eight 8 GB A1, A2, A3, A4, B1, B2, B3, B4 110 Installing Blade Components Table 3-3. Examples of PowerEdge M805 Memory Configurations (continued) Total System Memory Memory Modules Number and Size Memory Module Locations 128 GB Sixteen 8 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 *If 64 GB of memory is installed, the system will only recognize 63.75 GB during POST. Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during startup stating that your memory configuration is nonoptimal. Memory Sparing Support - PowerEdge M805 Memory sparing (spare bank) is supported in systems that have one of the memory configurations shown in Table 3-4. The memory sparing feature must also be enabled in the Memory Information screen of the System Setup program. See "Memory Information Screen" on page 83. To use memory sparing, you must disable node interleaving. Table 3-4. Memory Sparing Configurations - PowerEdge M805 Total System Memory Usable System Memory Memory Modules Number and Size Memory Module Locations 16 GB 12 GB Eight 2 GB A1, A2, A3, A4, B1, B2, B3, B4 32 GB 28 GB Sixteen 2 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 64 GB 56 GB Sixteen 4 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 128 GB 112 GB Sixteen 8 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 Installing Blade Components 111 System Memory - PowerEdge M600 You can upgrade your system memory to a maximum of 32 GB by installing 667-MHz registered DDRII fully-buffered DIMMs (FBDs). 512-MB, 1-GB, 2-GB, 4-GB, and 8-GB memory modules are supported. The memory module sockets are divided into two equal branches (0 and 1). Each branch consists of two channels and each channel consists of two memory module sockets: • Branch 0, Channel 0 consists of slot 1 and slot 5. • Branch 0, Channel 1 consists of slot 2 and slot 6. • Branch 1, Channel 2 consists of slot 3 and slot 7. • Branch 1, Channel 3 consists of slot 4 and slot 8. The first DIMM socket of each channel has white release tabs. Figure 3-9 shows the locations of the memory module sockets. Figure 3-9. Memory Locations - PowerEdge M600 8 4 7 3 6 2 5 1 112 Installing Blade Components General Memory Module Installation Guidelines - PowerEdge M600 To ensure optimal performance of your system, observe the following guidelines when configuring your system memory. • Memory modules must be installed in pairs of identically-sized DIMMs. The total number of memory modules must equal two, four, or eight. Six modules are not supported. • All memory modules in the blade must be identical in speed and technology. The memory modules in each pair must be the same size. For best system performance, all memory modules should be identical memory size, speed, and technology. • Memory sparing and memory mirroring require eight memory modules of identical size, speed, and technology. Memory sparing and memory mirroring cannot be implemented at the same time. Table 3-5 shows examples of supported memory configurations. NOTICE: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. Table 3-5. Total Memory Examples of Memory Configurations - PowerEdge M600 DIMM 1 2 3 4 5 6 7 8 blank 1 GB 512 MB 512 MB blank blank blank blank blank 2 GB 512 MB 512 MB 512 MB 512 MB blank blank blank blank 2 GB 1 GB blank blank blank 4 GB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 4 GB 1 GB 1 GB 1 GB 1 GB blank blank blank blank 8 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 8 GB 2 GB 2 GB 2 GB 2 GB blank blank blank blank 16 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 16GB 4 GB 4 GB 4 GB 4 GB blank blank blank blank 32 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 1 GB blank blank blank Installing Blade Components 113 Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during startup stating that your memory configuration is nonoptimal. Memory Sparing Support - PowerEdge M600 Memory sparing requires eight identical memory modules. The memory sparing feature must also be enabled in the System Setup program, and can be used only if memory mirroring is not enabled. Table 3-6 shows how memory sparing splits the available and spared memory in each memory module configuration. Table 3-6. Memory Sparing Configurations - PowerEdge M600 DIMMs Size/Type Total Memory Available Spare 8 512-MB 4 GB 2 GB 2 GB 8 1-GB single-rank 8 GB 4 GB 4 GB 8 2-GB dual-rank 16 GB 12 GB 4 GB 8 4-GB dual-rank 32 GB 24 GB 8 GB Memory Mirroring Support - PowerEdge M600 The system supports memory mirroring if eight identical memory modules are installed in the system. Mirroring must be enabled in the System Setup program and can be used only if memory sparing is not enabled. In a mirrored configuration, the total available system memory is one-half of the total installed memory. System Memory - PowerEdge M605 You can upgrade your system memory to a maximum of 16 GB (single processor) or 32 GB (dual processors) by installing 667- or 800-MHz registered DDR2 memory modules in sets of 512-MB, 1-GB, 2-GB, 4-GB, or 8-GB modules. Each processor has four memory channels, organized in sets of two channels. 114 Installing Blade Components Figure 3-10. Memory Locations - PowerEdge M605 A1 A2 A3 A4 B4 B3 B2 B1 General Memory Module Installation Guidelines - PowerEdge M605 To ensure optimal performance of your system, observe the following guidelines when installing your system memory. • Memory modules must be installed in pairs of identically-sized DIMMs, beginning with slots A1 and A2 (processor 1) and B1 and B2 (processor 2, if installed). These slots are marked by white ejector tabs. • All memory modules in the blade must be identical in speed and technology. The memory modules in each pair must be the same size. • In two-processor configurations, memory must be installed in the same configuration (symmetrically) for both processors. • If pairs of memory modules of different sizes are installed, the larger capacity memory modules must be installed in the lower numbered slots. • Memory sparing is supported if four (single-processor systems) or eight (dual-processor systems) memory modules are installed. Installing Blade Components 115 Table 3-7 and Table 3-8 show examples of supported single- and dualprocessor memory configurations. Single-Processor Memory Configurations NOTICE: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. Table 3-7. Total System Memory Single-Processor Memory Configurations - PowerEdge M605 CPU 1 A1 A2 A3 A4 1 GB 512 MB 512 MB blank blank 2 GB 512 MB 512 MB 512 MB 512 MB 2 GB 1 GB 1 GB blank blank 4 GB 1 GB 1 GB 1 GB 1 GB 4 GB 2 GB 2 GB blank blank 6 GB 2 GB 2 GB 1 GB 1 GB 8 GB 2 GB 2 GB 2 GB 2 GB 8 GB 4 GB 4 GB blank blank 12 GB 4 GB 4 GB 2 GB 2 GB 16 GB 4 GB 4 GB 4 GB 4 GB 32 GB 8 GB 8 GB 8 GB 8 GB 116 Installing Blade Components Dual-Processor Memory Configurations NOTICE: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. Table 3-8. Dual-Processor Memory Configurations - PowerEdge M605 Total System A1 Memory CPU1 A2 A3 CPU2 A4 B1 B2 B3 blank 512 MB 512 MB blank B4 2 GB 512 MB 512 MB blank 4 GB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 4 GB 1 GB 1 GB blank 1 GB 1 GB blank 6 GB 1 GB 1 GB 512 MB 512 MB 1 GB 1 GB 512 MB 512 MB 8 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 8 GB 2 GB 2 GB blank blank 2 GB 2 GB blank blank 12 GB 2 GB 2 GB 1 GB 1 GB 2 GB 2 GB 1 GB 1 GB 16 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 16 GB 4 GB 4 GB blank blank 4 GB 4 GB blank blank 24 GB 4 GB 4 GB 2 GB 2 GB 4 GB 4 GB 2 GB 2 GB 32 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 64 GB* 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB blank blank blank *If 64 GB of memory is installed, the system will only recognize 63.75 GB during POST. Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during startup stating that your memory configuration is nonoptimal. Installing Blade Components 117 Memory Sparing Support - PowerEdge M605 Memory sparing is supported in single- or dual-processor systems that have one of the fully populated memory configurations shown in Table 3-9. The memory sparing feature must be enabled in the Memory Information screen of the System Setup program. See "Memory Information Screen" on page 83. To use memory sparing, you must disable node interleaving. Memory sparing allocates only the first rank of memory of a DIMM. For a single-rank DIMM, the entire capacity of the DIMM must be allocated for sparing along with the adjacent single-rank DIMM to spare a memory channel. For dual-rank DIMMs, two DIMMs are also required for sparing, but as only the first rank of each DIMM is allocated, only half of a dual-rank DIMM’s capacity is allocated for sparing. The second ranks on both DIMMs are available memory. Table 3-9 shows how memory sparing splits the available and spared memory in each memory module configuration. 118 Installing Blade Components Table 3-9. Memory Sparing Configurations - PowerEdge M605 Processor 1 Available Memory Processor 2 DIMM DIMM DIMM DIMM DIMM DIMM DIMM DIMM 1 CPU / 1 2 3 4 5 6 7 8 2 CPUs 512 MB 512 MB Spared Memory 1 CPU / 2 CPUs 512 MB 512 MB 512 MB 512 MB 512 MB 512 MB 1 GB / 2 GB 1 GB / 2 GB 1 GB 1 GB 512 MB 512 MB 1 GB 1 GB 512 MB 512 MB 1 GB / 2 GB 2 GB / 4 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 2 GB / 4 GB 2 GB / 4 GB 2 GB 2 GB 512 MB 512 MB 2 GB 2 GB 512 MB 3 GB / 6 GB 2 GB / 4 GB 2 GB 2 GB 1 GB 1 GB 2 GB 2 GB 1 GB 1 GB 4 GB / 8 GB 2 GB / 4 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 6 GB / 12 GB 2 GB / 4 GB 4 GB 4 GB 512 MB 512 MB 4 GB 4 GB 512 MB 512 MB 5 GB / 10 GB 4 GB / 8 GB 4 GB 4 GB 1 GB 1 GB 4 GB 4 GB 1 GB 1 GB 6 GB / 12 GB 4 GB / 8 GB 4 GB 4 GB 2 GB 2 GB 4 GB 4 GB 2 GB 2 GB 8 GB / 16 GB 4 GB / 8 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 1 GB 4 GB 512 MB 12 GB / 24 4 GB / 8 GB GB Indicates a spared single-rank DIMM (512-MB or 1-GB). The entire capacity of this DIMM is reserved for sparing. Indicates a spared dual-rank DIMM (2-GB and higher). One-half of this DIMM’s capacity is reserved for sparing. Installing Blade Components 119 Installing Memory Modules CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. CAUTION: The memory modules are hot to the touch for some time after the blade has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Locate the memory module sockets. See Figure 7-3 or Figure 7-4. 4 PowerEdge 905 systems only - You must slide the system board back in the blade chassis to access memory sockets C1 through C4 and D1 through D4. See step 1 through step 7 in "Removing the System Board" on page 150. 5 Press the ejectors on the memory module socket down and out, as shown in Figure 3-11, to allow the memory module to be inserted into the socket. If a memory module blank is installed in the socket, remove it. 120 Installing Blade Components Figure 3-11. Installing and Removing a Memory Module or Memory Module Blank 2 1 3 4 5 1 memory module 2 edge connector 3 ejectors (2) 4 socket 5 alignment key 6 Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket. NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way. 7 Press down on the memory module with your thumbs to lock the memory module into the socket. When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed. 8 Repeat step 5 through step 7 of this procedure to install the remaining memory modules. See Table 3-5, Table 3-7, or Table 3-8 for sample memory configurations. 9 PowerEdge 905 systems only - If you removed the system board to access the memory modules, reinstall the system board. 10 Close the blade. See "Closing the Blade" on page 104. 11 Install the blade. See "Installing a Blade" on page 98. Installing Blade Components 121 12 (Optional) Press <F2> to enter the System Setup program, and check the System Memory setting on the main System Setup screen. The system should have already changed the value to reflect the newly installed memory. 13 If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 1 through step 12 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets. 14 Run the system memory test in the system diagnostics. See "Running System Diagnostics" on page 197. Removing Memory Modules CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. CAUTION: The DIMMs are hot to the touch for some time after the blade has been powered down. Allow time for the DIMMs to cool before handling them. Handle the DIMMs by the card edges and avoid touching the DIMM components. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Locate the memory module sockets. See Figure 7-3 or Figure 7-4. 4 PowerEdge 905 systems only - You must slide the system board back in the blade chassis to access memory sockets C1 through C4 and D1 through D4. See step 1 through step 7 in "Removing the System Board" on page 150. 5 Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 3-11. 6 PowerEdge 905 systems only - If you removed the system board to access the memory modules, reinstall the system board. 7 Close the blade. See "Closing the Blade" on page 104. 8 Install the blade. See "Installing a Blade" on page 98. 122 Installing Blade Components I/O Module Mezzanine Cards The blades support a variety of optional mezzanine cards. If installed, the mezzanine card(s) must be used in conjunction with a matching appropriate I/O module(s). (For more information on I/O modules, see "Guidelines for Installing I/O Modules" on page 42.) Mezzanine Card Installation Guidelines PowerEdge M905 and M805 The full-height PowerEdge M905 and M805 blades support up to four mezzanine cards. • Slot 1 and slot 3 support Fabric C. If a card is installed in both slots, both cards must be identical. They must also match the fabric type of the I/O modules installed in I/O module bays C1 and C2. • Slot 2 and slot 4 support Fabric B. If a card is installed in both slots, both cards must be identical. They must also match the fabric type of I/O module installed in I/O module bays B1 and B2. NOTE: The four mezzanine card slots do not need to be fully populated. If a blade does require support by a particular fabric and only two external I/O port connections are needed, only one mezzanine card is required. For example, a Fibre Channel I/O module in I/O bay C1 or C2 only requires one Fibre Channel mezzanine card in slot 1 or slot 3 in the blade. If a blade does not require support from a particular fabric, a mezzanine card is not required in either of the corresponding mezzanine card slots. PowerEdge M600 and M605 The half-height PowerEdge M600 and M605 blades support two mezzanine cards: • Mezzanine card slot C supports Fabric C. This card must match the fabric type of I/O modules installed in I/O module bays C1 and C2. • Mezzanine card slot B supports Fabric B. This card must match the fabric type of I/O modules installed in I/O module bays B1 and B2. Installing Blade Components 123 Installing a Mezzanine Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Open the mezzanine card latch by pressing the ridged area on the latch with your thumb and lifting the end of the latch. See Figure 3-12 or Figure 3-13. Figure 3-12. Installing and Removing a Mezzanine Card - Full-Height Blades 4 3 2 1 7 6 5 124 1 optional Fabric C mezzanine card 1 2 optional Fabric B mezzanine card 2 3 optional Fabric C mezzanine card 3 4 optional Fabric B mezzanine card 4 Installing Blade Components 5 retention latch 7 mezzanine card Figure 3-13. 6 mezzanine card connector Installing and Removing a Mezzanine Card - Half-Height Blades 4 3 2 5 1 1 Fabric C mezzanine card slot 2 Fabric B mezzanine card slot 3 mezzanine card 4 mezzanine card connector 5 retention latch 4 If present, remove the connector cover from the mezzanine card bay. NOTICE: Hold the mezzanine card by its edges only. Installing Blade Components 125 5 Mezzanine cards are designed to fit in either card slot. Rotate the card to align the connector on the bottom of the mezzanine card with the corresponding socket on the blade board. 6 Lower the card into place until it is fully seated and the plastic clip on the outer edge of the card fits over the side of the blade chassis. 7 Close the retention latch to secure the mezzanine card. 8 Close the blade. See "Closing the Blade" on page 104. 9 Install the blade. See "Installing a Blade" on page 98. Removing a Mezzanine Card CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Open the mezzanine card latch by pressing the ridged area on the latch with your thumb, and lifting the end of the latch. See Figure 3-13. NOTICE: Hold the mezzanine card by its edges only. 4 Lift up the mezzanine card straight up from the system board. 5 Close the retention latch. 6 Close the blade. See "Closing the Blade" on page 104. 7 Install the blade. See "Installing a Blade" on page 98. Installing an SD Card (PowerEdge M905 and M805) Locate the SD card slot on the system board and insert the contact-pin end of the card into the slot with the label on the card facing upwards. See Figure 3-14. 126 Installing Blade Components Figure 3-14. Installing an SD Card (PowerEdge M805 and M905 Only) 1 1 2 SD card 2 SD card connector Integrated NIC Hardware Key TOE, iSCSI, and other future functionality for the blade’s integrated NICs is enabled by installing a NIC hardware key in the TOE_KEY socket on the system board (see Figure 7-3 or Figure 7-4.) NOTE: TOE Operating system support and the Microsoft scalable network pack are required for TOE functionality. Installing Blade Components 127 Figure 3-15. Installing a NIC Hardware Key 1 2 1 NIC hardware key 2 connector on system board Processors NOTE: The following removal and installation procedures apply to the PowerEdge M905, M805, M605, and M600 blades. Appropriate illustrations are provided for each type of processor. Processor Installation Guidelines PowerEdge 905 Systems 128 • The PowerEdge 905 supports dual-core or quad-core AMD™ Opteron™ 8xxxx Series processors only. • Four processors must be installed; dual-processor configurations are not supported • Only AMD 8xxxx MP series processors are supported. Installing Blade Components PowerEdge 805 Systems • The PowerEdge 805 supports dual-core or quad-core AMD Opteron 2xxxx Series processors only. • In a PowerEdge 805 system, two processors must be installed; a single-processor configuration is not supported. • Hypertransport (HT) bridge cards must be installed in sockets CPU3 and CPU4. See "HT Bridge Card (Service Only)" on page 138. PowerEdge 605 Systems • The PowerEdge 605 supports dual-core or quad-core AMD Opteron 2xxxx MP Series processors only. • Both single and dual-processor configurations are supported. PowerEdge 600 Systems • The PowerEdge 600 supports dual-core or quad-core Intel ® Xeon® processors only. • Both single and dual-processor configurations are supported. Removing a Processor CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. CAUTION: The processor and heat sink can become extremely hot. Be sure the processor has had sufficient time to cool before handling. NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions. 3 Loosen the four screws that secure the heat sink to the system board. See Figure 3-16 (PowerEdge M905), Figure 3-17 (PowerEdge M805), Figure 3-18 (PowerEdge M600) or Figure 3-19 (PowerEdge M605). Installing Blade Components 129 Figure 3-16. Installing and Removing the Heat Sink (PowerEdge M905) 2 1 3 4 6 5 130 1 heat sink You must install the heatsink in the orientation shown here. 2 screws (4) 3 socket CPU2 4 socket CPU4 5 socket CPU3 6 socket CPU1 Installing Blade Components Figure 3-17. Installing and Removing a Heat Sink (PowerEdge M805) 1 2 3 4 1 heat sink You must install the heatsink in the orientation shown here. 2 screws (4) 3 socket CPU2 4 socket CPU1 Installing Blade Components 131 Figure 3-18. Installing and Removing a Heat Sink (PowerEdge M600) 1 2 3 4 132 1 heat sink 2 screws (4) 3 socket CPU1 4 socket CPU2 Installing Blade Components Figure 3-19. Installing and Removing a Heat Sink (PowerEdge M605) 1 2 4 3 1 heat sink 2 screws (4) 3 socket CPU2 4 socket CPU1 4 Remove the heat sink. Set the heat sink upside down on the work surface to avoid contaminating the thermal grease. 5 Use a clean lint-free cloth to remove any thermal grease from the surface of the processor shield. 6 Pull the socket-release lever straight up until the processor is released from the socket. See Figure 3-20 (PowerEdge M600) or Figure 3-21 (PowerEdge M905, M805, or M605). Installing Blade Components 133 Figure 3-20. Installing and Removing an Intel Processor (PowerEdge M600) 2 3 4 1 6 5 134 1 socket-release lever 2 processor 3 processor shield 4 notch in processor 5 pin-1 corner of socket 6 pin-1 corner of processor Installing Blade Components Figure 3-21. M605) Installing and Removing an AMD Processor (PowerEdge M905, M805, or 3 4 2 5 1 6 1 pin-1 corner of socket 2 pin-1 corner of processor 3 processor 4 socket-release lever 5 processor shield 6 notch in processor Installing Blade Components 135 7 Open the processor shield and then lift the processor out of the socket. Leave the release lever up so that the socket is ready for the new processor. Installing a Processor 1 If you are adding a processor to an unoccupied socket, perform the following steps first. NOTE: If you are installing just one processor, it must be installed in socket CPU1. See Figure 7-3 or Figure 7-4. a Remove the processor filler blank b Lift the plastic processor socket cover from the socket. c Unlatch and rotate the socket-release lever 90 degrees upward. d Lift the processor shield. 2 Install the processor in the socket. See Figure 3-20 (PowerEdge M600) or Figure 3-21 (PowerEdge M905, M805, or M605). NOTE: Positioning the processor incorrectly can permanently damage the processor and the system board when you turn it on. Be careful not to bend the pins on the LGA socket. a Identify the pin-1 corner of the processor by locating the tiny gold triangle on one corner of the processor. Place this corner in the same corner of the ZIF socket identified by a corresponding triangle on the system board. Align the pin-1 corner of the processor with the pin-1 corner of the ZIF socket. See Figure 3-20 (PowerEdge M600) or Figure 3-21 (PowerEdge M905, M805, or M605). b Ensure that the socket-release lever is fully open. c With the pin-1 corners of the processor and socket aligned, set the processor lightly in the socket. Because the system uses a ZIF processor socket, do not use force. When the processor is positioned correctly, it drops down into the socket with minimal pressure. 136 d Close the processor shield. e Rotate the socket release lever down until it snaps into place, securing the processor. Installing Blade Components 3 Install the heat sink. See Figure 3-18 (PowerEdge M600) or Figure 3-19 (PowerEdge M905, M805, or M605). a If you are reinstalling a heat sink, use a clean lint-free cloth to remove the existing thermal grease from the heat sink. If you are upgrading a processor and a new heat sink was supplied with the processor, install the new heat sink. If you are reinstalling a processor, also clean any remnants of thermal grease from the processor. b Apply thermal grease evenly to the top of the processor. c Place the heat sink onto the processor. The heat sink must match the orientation shown in Figure 3-16 (PowerEdge M905), Figure 3-17 (PowerEdge M805), Figure 3-18 (PowerEdge M600) or Figure 3-19 (PowerEdge M605). NOTE: Do not over-tighten the heat sink retention screws when installing the heat sink. To prevent over-tightening, tighten the retention screw until resistance is felt and stop once the screw is seated. The screw tension should be no more than 6 in-lb (6.9 kg-cm). d Carefully tighten the four screws to secure the heat sink to the blade board. 4 Close the blade. See "Closing the Blade" on page 104. 5 Install the blade. See "Installing a Blade" on page 98. As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup program. 6 Press <F2> to enter the System Setup program, and check that the processor information matches the new system configuration. See "Using the System Setup Program" on page 79 for instructions about using the System Setup program. 7 Run the system diagnostics to verify that the new processor operates correctly. See "Running System Diagnostics" on page 197 for information about running the diagnostics and troubleshooting processor problems. 8 Update the system BIOS. Installing Blade Components 137 HT Bridge Card (Service Only) An HT (hypertransport) bridge card must be installed in the third and fourth CPU sockets on the PowerEdge M805 system board. Consequently, if you replace the system board, you must transfer the HT bridge cards to the replacement planar. Removing an HT Bridge Card CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Remove the blade. "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Pull the socket-release lever straight up until the bridge card is released from the socket. See Figure 3-22. 4 Open the processor shield and then lift the card out of the socket. 138 Installing Blade Components Figure 3-22. Installing and Removing an HT Bridge Card (PowerEdge M805 Only) 2 1 3 4 1 HT bridge card 2 socket-release lever 3 processor shield 4 notch in card Installing an HT Bridge Card 1 Perform the following steps to prepare the two sockets on the new system board: a Remove the processor filler blank b Lift the plastic processor socket cover from the socket. c Unlatch and rotate the socket-release lever 90 degrees upward. d Lift the processor shield. e Repeat steps a through d to prepare the second processor socket. Installing Blade Components 139 2 Install the bridge card in the socket. See Figure 3-22. NOTE: Positioning the card incorrectly can permanently damage the card and the system board when you turn the system on. Be careful not to bend the pins on the LGA socket. a Identify the pin-1 corner of the card by locating the tiny gold triangle on one corner of the card. Place this corner in the same corner of the ZIF socket identified by a corresponding triangle on the system board. b Ensure that the socket-release lever is fully open. c With the pin-1 corners of the card and socket aligned, set the processor lightly in the socket. Because the system uses a ZIF processor socket, do not use force. When the card is positioned correctly, it drops down into the socket with minimal pressure. d Close the processor shield. e Rotate the socket release lever down until it snaps into place, securing the card. 3 Close the blade. See "Closing the Blade" on page 104. 4 Install the blade. See "Installing a Blade" on page 98. Blade System Board NVRAM Backup Battery The NVRAM backup battery is a 3.0-volt (V), coin-cell battery. Removing and Installing the NVRAM Backup Battery CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. CAUTION: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. See the safety instructions that came with your system for additional information. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 140 Installing Blade Components 3 If you are replacing the battery in a PowerEdge M905, M805, or M605 system, you must remove the system board to access the battery. See "Blade System Board (Service Only)" on page 150. 4 Remove the battery by lifting it straight up from its connector. See Figure 3-23. See Figure 7-1 (PowerEdge M905), Figure 7-2 (PowerEdge M805), Figure 7-3 (PowerEdge M600), or Figure 7-4 (PowerEdge M605) to locate the battery on the blade board. 5 Install the new battery with the side labeled "+" facing up. See Figure 3-23. Figure 3-23. Replacing the NVRAM Backup Battery 1 2 1 "+" side of battery 2 battery connector 6 If you removed the system board to replace the battery, reinstall the board now. See "Blade System Board (Service Only)" on page 150. 7 Close the blade. See "Closing the Blade" on page 104. 8 Install the blade. See "Installing a Blade" on page 98. 9 Enter the System Setup program to confirm that the battery is operating properly. See "Using the System Setup Program" in your User's Guide. 10 Enter the correct time and date in the System Setup program's Time and Date fields. 11 Exit the System Setup program. Installing Blade Components 141 12 To test the newly installed battery, remove the blade for at least an hour. See "Removing a Blade" on page 96. 13 After an hour, reinstall the blade. See "Installing a Blade" on page 98. 14 Enter the System Setup program and if the time and date are still incorrect, see "Getting Help" on page 217 for instructions about obtaining technical assistance. Hard Drives • The PowerEdge M805 and M905 blades support one or two hot-pluggable 2.5 inch SAS hard drives. • The PowerEdge M600 and M605 blades support one or two hot-pluggable 2.5-inch SATA hard drives and one or two 2.5 inch SAS hard drives. NOTE: SAS and SATA hard drives cannot be mixed within a blade. NOTE: SATA hard drives are not hot pluggable with the SATA repeater daughter card. Hard-Drive Installation Guidelines • If a SATA RAID controller storage card is installed, the blade supports hotplug drive removal and installation. • If only one hard drive is used, a blank must be installed to maintain proper cooling. Installing a Hard Drive NOTICE: When a replacement hot-pluggable hard drive is installed and the blade is powered on, the hard drive automatically begins to rebuild. Make absolutely sure that the replacement hard drive is blank or contains data that you wish to have over-written. Any data on the replacement hard drive is immediately lost after the hard drive is installed. NOTICE: Not all operating systems support hot-plug drive installation. See the documentation supplied with your operating system. 1 Open the hard-drive carrier handle. See Figure 3-24. 142 Installing Blade Components Figure 3-24. Installing a Hard Drive (Half-Height Blade Shown) 2 1 3 4 1 hard drive carrier 2 hard drive bay 0 3 hard drive bay 1 4 carrier handle 2 Insert the hard-drive carrier into the drive bay. 3 Close the hard-drive carrier handle to lock it in place. Removing a Hard Drive NOTICE: Not all operating systems support hot-plug drive installation. See the documentation supplied with your operating system. 1 Take the hard drive offline and wait until the hard-drive indicator codes on the drive carrier signal that the drive may be removed safely. See Figure 1-8. When all indicators are off, the drive is ready for removal. Installing Blade Components 143 See your operating system documentation for more information on taking the hard drive offline. 2 Open the hard-drive carrier handle to release the drive. See Figure 3-24. 3 Slide the hard drive out until it is free of the drive bay. If you are permanently removing the hard drive, install a blank insert. Shutdown Procedure for Servicing a Hard Drive NOTE: This section applies only to situations where the blade must be powered down to service a hard drive. In many situations, the hard drive can be serviced while the blade is powered on. If you need to power off the blade to service a hard drive, wait 30 seconds after the blade’s power indicator turns off before removing the hard drive. Otherwise, the hard drive may not be recognized after the hard drive is reinstalled and the blade is powered on again. Configuring the Boot Drive The drive or device from which the system boots is determined by the boot order specified in the System Setup program (see "Using the System Setup Program" on page 79. Removing a Hard Drive From a Hard-Drive Carrier Remove the four screws from the slide rails on the hard-drive carrier and separate the hard drive from the carrier. See Figure 3-24. Installing a Hard Drive In a Drive Carrier 1 Insert the hard drive into the hard-drive carrier with the connector end of the drive at the back of the carrier. See Figure 3-24. 2 Align the screw holes on the hard drive with the holes on the hard-drive carrier. 3 Attach the four screws to secure the hard drive to the hard-drive carrier. 144 Installing Blade Components Figure 3-25. Removing and Installing a Hard Drive In a Drive Carrier 1 2 3 1 hard drive 3 screws (4) 2 drive carrier Video Controller Follow these steps to replace the video controller. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Remove the video controller: • If you are removing the video controller from a PowerEdge M600, press the latch on the upper edge of the video riser card, then lift the card from the blade. See Figure 3-26. • If you are removing the video controller from a PowerEdge M605, M805, or M905, remove the two torx screws securing the daughter card, then lift the card from the blade. See Figure 3-27. Installing Blade Components 145 Figure 3-26. Removing and Installing a Video Riser Card (PowerEdge M600) 1 2 3 146 1 video riser card 3 connector on system board Installing Blade Components 2 latch Figure 3-27. Removing and Installing a Video Controller Daughter Card (PowerEdge M605 Shown) 1 2 3 1 video controller board 3 connector on system board 2 torx screws (2) 4 To install a new video controller: • If you are installing a video controller in a PowerEdge M600, align the edge connector on the riser card with the connector on the system board, then lower the riser card into place until the connector is fully seated and the latch snaps into place. See Figure 3-26. • If you are installing a video controller in a PowerEdge M605, align the connector on the underside of the controller card with the connector on the system board, then lower the card into place. Secure the card with the two screws. See Figure 3-27. Installing Blade Components 147 Hard-Drive Backplane Follow these steps to remove and replace the hard-drive backplane. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. NOTICE: If you are removing two hard drives, label them so you can replace them in their original locations. NOTICE: You must remove the hard drives before removing the backplane. 3 Remove the hard drive(s). See "Removing a Hard Drive" on page 143. 4 Lift the latches at each end of the backplane, then lift the backplane from the blade chassis. See Figure 3-28. 148 Installing Blade Components Figure 3-28. Shown) Removing and Installing the Hard-Drive Backplane (PowerEdge M605 2 3 4 1 5 1 hard-drive backplane 2 hard-drive connectors (2) 3 retention hooks (3) 4 latches (2) 5 backplane connector on system board 5 To install the hard-drive backplane: a Hold the backplane with the drive connectors facing towards the hard drive bays. b Position the backplane so that the retention hooks on the end of the drive bay are aligned with the corresponding slots in the backplane. c Press the backplane into place until the connector. is fully seated and the latches at each end snap over the upper edge of the board. 6 Replace the hard drive(s). If you are installing two drives, be sure and reinstall them in their original locations. Installing Blade Components 149 7 Close the blade. See "Closing the Blade" on page 104. 8 Install the blade in the system. See "Installing a Blade" on page 98. Blade System Board (Service Only) Removing the System Board CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Remove the blade. See "Removing a Blade" on page 96. 2 Install an I/O connector cover on the I/O connector(s) at the back of the board. 3 Open the blade. See "Opening the Blade" on page 100. CAUTION: The processor and heat sink can become extremely hot. Be sure the processor has had sufficient time to cool before handling. CAUTION: The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components. NOTICE: If you are removing two hard drives, label them so you can replace them in their original locations. 4 Remove the hard drives. See "Removing a Hard Drive" on page 143. 5 Remove the hard-drive backplane. See "Hard-Drive Backplane" on page 148. 6 For a PowerEdge M905 or M805 blade, remove mezzanine cards 1 and 4 (the outermost mezzanine cards). For a PowerEdge M605 or M600 blade, remove both mezzanine cards if present. NOTICE: If you are removing multiple mezzanine cards, label them so you can replace them in their original locations. 150 Installing Blade Components 7 To remove a full-height blade system board: a Use the thumb and index fingers of your right hand to lift the system board retention pin. See Figure 3-29. b Keeping the retention pin raised with your index finger, press the corner of the blade chassis with your thumb to slide the system board out of the open end of the chassis. Figure 3-29. Removing and Installing the System Board - Full-Height Blades 2 1 4 3 1 system board 2 system board retention pin 3 tabs on system chassis 4 slots in system board tray Installing Blade Components 151 To remove a half-height blade system board, hold the blade chassis with one hand, lift and pull the system board retention latch with the other hand, and then slide the system board out of the open end of the chassis. See Figure 3-30. Figure 3-30. Removing and Installing the System Board - Half-Height Blades 1 2 3 5 4 1 I/O connector cover 2 retention latch 3 system board 4 tabs on system chassis 5 slots in system board tray NOTICE: If you are removing multiple mezzanine cards, label them so you can replace them in their original locations. 8 Insure that the I/O connector cover is still in place on the I/O connector at the back of the board. See Figure 3-29 or Figure 3-30. 152 Installing Blade Components 9 Remove the video riser card or daughter card. See "Video Controller" on page 145. 10 Remove the memory modules and memory module blanks. See "Removing Memory Modules" on page 122. 11 Remove the processor(s). See "Removing a Processor" on page 129. 12 Remove the storage controller board. See "Removing the Storage Controller Board" on page 154. 13 Remove the TOE or iSCSI activation key. See "System Board Connectors" on page 207 for the location of the key. Installing the System Board CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin this procedure, review the safety instructions that came with the system. 1 Transfer the following components to the new system board: • TOE or iSCSI activation key. See "System Board Connectors" on page 207 for the location of the key. • Storage controller board. See "Installing the Storage Controller Board" on page 155. • Memory modules and memory module blanks. See "Installing Memory Modules" on page 120. • Processor(s) and heat sink(s), or processor filler blank. See "Installing a Processor" on page 136. • HT bridge cards (PowerEdge M805 only). See "HT Bridge Card (Service Only)" on page 138. 2 Slide the new system board into the open end of the blade chassis until the retention latch or retention pin engages. NOTE: Ensure that the system board plate is parallel with the chassis. When the board assembly is installed correctly, the tabs on the system board pan fit into the corresponding openings in the floor of the blade chassis. See Figure 3-29 or Figure 3-30. 3 Reinstall the video daughter card or video riser card. See "Video Controller" on page 145. Installing Blade Components 153 4 Replace the mezzanine card(s) in their original locations. See "Installing a Mezzanine Card" on page 124. 5 Reinstall the hard-drive backplane. See "Hard-Drive Backplane" on page 148. 6 Replace the hard drive(s). • If there are two drives, be sure and reinstall them in their original locations. • If only one hard-drive is installed, install it in bay 0. 7 Close the blade. See "Closing the Blade" on page 104. 8 Remove the plastic I/O connector covers from the back of the blade. 9 Install the blade in the system. See "Installing a Blade" on page 98. Storage Controller Card (Service Only) The storage controller board is located underneath the drive bays. Removing the Storage Controller Board 1 Remove the blade. See "Removing a Blade" on page 96. 2 Open the blade. See "Opening the Blade" on page 100. 3 Remove the system board and place it on the work surface. See "Removing the System Board" on page 150. 4 Open the release lever to disengage the controller board edge connector from the system board connector. 5 Lift the controller board straight up from the system board. 154 Installing Blade Components Figure 3-31. Shown) Removing and Installing the Storage Controller Card (Half-Height Blade 1 1 storage controller card 2 2 release lever Installing the Storage Controller Board 1 To place the storage controller board onto the system board, align the controller board so that the tabs on the metal system board tray fit through the corresponding notches in the edges of the controller board. 2 Slide the board towards the connector on the system board until the boards’s edge connector is fully seated. 3 Reinstall the system board. See "Installing the System Board" on page 153. 4 Close the blade. See "Closing the Blade" on page 104. 5 Install the blade in the system. See "Installing a Blade" on page 98. Installing Blade Components 155 156 Installing Blade Components Installing Enclosure Components The procedures in this section describe how to remove and install components in the M1000e enclosure, including: • Power supply modules • Fan modules • Chassis Management Controller (CMC) modules • iKVM module • I/O modules • Blades • Enclosure midplane (service-only procedure) • Enclosure control panel assembly (service-only procedure) • LCD panel (service-only procedure) Installing Enclosure Components 157 Power Supply Modules The M1000e enclosure supports up to six hot-pluggable power supply modules, accessible from the enclosure back panel. NOTE: The 2360-W power supply modules require 200–240 V input from a PDU. If the power supply modules are plugged into 110-V electrical outlets, the system will not power up. NOTE: In addition to supplying power to the system, the power supply modules also have internal fans that provide thermal cooling for the blades. A power supply module must be replaced if an internal fan failure occurs. System Power Guidelines Your system has one of the following power supply configurations: • Three 2360-W power supply modules, which do not provide redundancy if one power supply module fails. The power supplies are installed in bays 1 though 3. • Six 2360-W power supply modules, which provide redundancy if up to three power supply modules fail. The CMC module controls power management for the system. You can program the CMC to configure the power budget, redundancy, and dynamic power of the entire enclosure (chassis, servers, I/O modules, iKVM, CMC, and power supplies). The power management service optimizes power consumption and re-allocates power to different modules based on real-time demand. For more information, see "Power Management" in the Dell Chassis Management Controller User’s Guide. NOTE: The wattage of a power supply module is listed on its regulatory label. NOTICE: PDU inlet cords for this system may be too thick to fit in the wire guides installed in the rack vertical rails. If this is the case, remove the wire guides by removing the attachment screw securing each guide. Route the PDU inlet cords along the vertical rails, securing them with tie wraps or Velcro strips. Power Supply Blanks If the M1000e enclosure is operated with only three power supplies, power supply blanks must be installed in the three unoccupied power supply bays (4 through 6) to maintain proper cooling airflow in the enclosure. 158 Installing Enclosure Components Removing a Power Supply Module NOTICE: The power supply modules are hot-pluggable. Remove and replace only one power supply module at a time in a system that is turned on. 1 Release the power cord retention clip and disconnect the power cord from the power supply module. See Figure 4-1. Figure 4-1. Power Cable Retention Clip 2 1 3 4 5 1 power supply 2 retention clip tether 3 notch in power supply handle 4 retention clip 5 power cable 2 Press down on the power supply module release button on the handle. See Figure 4-2. Installing Enclosure Components 159 Figure 4-2. Removing and Installing a Power Supply Module 1 2 3 1 power supply 3 release button 2 handle 3 Rotate the power supply module handle down to eject the power supply module. 4 Slide the power supply module out of the enclosure. Installing a Power Supp