Download chapter 1 - Regal Australia
Transcript
Chapter 6 - Parameter Description [APP] 1st Functions [Stall Level] FU1-61 [ETH 1min] FU1-62 [ETH cont] FU2-43 Motor rated current [Rated-Curr] Description level ETH level for 1 minute ETH level for continuous Note: Sleep function is not operated if the Sleep Delay Time (APP-29) set to ‘0’. Actual quantity Wakeup level (APP-29) Tartget Time The 1st functions are applied if the assigned multifunction terminal is not defined as ‘2nd Func’ nor ON. The 2nd function parameters are applied when the multifunction input terminal set to ‘2nd Func’ is ON. Parameters not listed on the table above are same as the 1st function. Freq. t<APP-27 Sleep delay (APP-27) Sleep freq (APP-28) Time Main motor Stop ☞ Caution: Exchange the motor connection from the 1st motor to the 2nd motor or the opposite when the motor is stopped. Over voltage or over current fault may occur when the motor is exchanged during operation. Start [Sleep Operation] APP-30 ~ APP-39: 2nd Functions APP►2nd Acc time 30 5.0 sec Factory Default: 31 10.0 sec Acceleration time Deceleration time Base Frequency Volts/Hz mode Forward torque boost Reverse torque boost Stall prevention 1st Functions DRV-01 [Acc. time] DRV-02 [Dec. time] FU1-31 [Base freq] FU1-40 [V/F Pattern] FU2-68 [Fwd Boost] FU2-69 [Rev Boost] FU1-60 APP-40: Number of Running Aux. Motor Display APP-40~APP-72: MMC Operation Control 10.0 10.0 These functions APP-30 ~ APP-39 are displayed only when one of the multifunction inputs in codes I/O-20 to I/O-27 is set at ‘2nd func’. When an inverter is controlling two motors by exchanging, different values can be set for the 2nd motor by using the multifunction input terminal. Following a cross reference table shows the 2nd functions corresponding to the 1st functions. Description Note: The ‘User V/F’ function of FU1-40 [V/F Pattern] is commonly used for the 1st and the 2nd motor. 5.0 5.0 5.0 sec APP►2nd Dec time 31 10.0 sec Factory Default: 30 2nd Functions [2nd Stall] APP-37 [2nd ETH 1min] APP-38 [2nd ETH cont] APP-39 [2nd R-Curr] APP► Aux Mot Run 40 0 Factory Default: 0 40 0 0 This code shows how many auxiliary motors are run by MMC control. [MMC]: The ‘PID’ control should be selected in APP-02 to use this function. One inverter can control multiple motors. This function is often used when controlling the rate and pressure of flow in fans or pumps. Built-in PI controller controlsa main motor after receiving process control feedback value and keeps the control value constant by connecting auxiliary motors to commercial line when needed. 2nd Functions APP-30 [2nd Acc time] APP-31 [2nd Dec time] APP-32 [2nd BaseFreq] APP-33 [2nd V/F] APP-34 [2nd F-boost] APP-35 [2nd R-boost] APP-36 In case that flow rate or flow pressure is beyond or below the reference so the main motor cannot control by itself, auxiliary motors are automatically turned on/off. Maximum four (Aux.1-4 output) auxiliary 6-60