Download RUGGEDCOM WiN7000
Transcript
RUGGEDCOM WiN7000 Chapter 3 Installation Guide Installation Procedures Item Quantity Description 2 1 WiN7000 3 4 Screw NC 1/4" × 1/2" hex 4 4 Washer flat NC 1/4" 5 4 Washer spring NC 1/4" 6 2 Bolt NC 1/4" 7 4 Screw 5/16" hex cap × 2" 8 4 Washer flat 5/16" 9 4 Washer spring 5/16" 10 4 Dowel 5/16" 11 1 Mounting upper bracket Procedure: Installing the WiN7000 on a Wall 1. Select a mounting location. 2. Place the mounting bracket on the wall and mark the location of the four mounting holes, two at the top and two at the bottom. 3. With a 5/16" drill bit suitable for the wall material, drill holes at the marked locations. 4. Insert the 5/16" dowels (Item 10) into the holes. 5. Assemble four 5/16" flat washers (Item 8), four 5/16" spring washers (Item 9), and four 5/16" × 2" hex cap screws (Item 7) into the holes on the mounting bracket. 6. Secure the mounting bracket to the wall. 7. Lift the base station by the eye bolts and secure it to the mounting bracket. At the top of the unit and mounting bracket, use NC 1/4" × 1/2" hex screws (Item 3), NC 14" flat washers (Item 4), and NC 1/4" spring washers (Item 5). 8. Complete the wiring connections. NOTE Seal all connectors with self-fusing electrical tape or insulating putty suitable for use in the unit’s installation environment. For more information on sealing the connectors, see Section 3.6, “Weatherproofing”. Section 3.5.5 Tower Mount Follow the same procedure as for wall mounting; see Section 3.5.4, “Wall Mounting”. Ensure that the tower can hold the load of the base station. Tower Mount 15