ALARMS AND WARNINGS LIST
SHOWN ON DISPLAY (SCROLLING) "TOO HIGH SMOKE TEMPERATURE"
Smoke temperature above maximum temperature ("Smoke
Max", in the ALARMS submenu) and timeout expired
ABNORMAL DESCRIPTION Temp.
(timeout duration displays "HIGH SMOKE TEMPERATURE",
see warnings list)
During the Alarm phase: Ignition Heater OFF, Auger OFF,
Motor to maximum speed, until stove cold (smoke
ACTIONS TAKEN Smoke
temperature below threshold of "Smoke Temperat." in
LIGHTING OFF submenu)
USER RESET Display knob depressed for 5s
SHOWN ON DISPLAY (SCROLLING) "SMOKE MOTOR KO"
ABNORMAL DESCRIPTION Damaged Smoke Motor Output (delayed alarm)
ACTIONS TAKEN During the Alarm phase: Ignition heater OFF, Auger OFF
USER RESET Display knob depressed for 5s
DISPLAY SAVED TO EVENTS LOG "SMOKE OUT DAMAGED"
(INTERNAL MEMORY)
DISPLAY SAVED TO EVENTS LOG "SMOKE T HIGH"
(INTERNAL MEMORY)
SHOWN ON DISPLAY (SCROLLING) "OBSTRUCTED CHIMNEY"
ABNORMAL DESCRIPTION Air Pressure Switch tripped (open contact)
During the Alarm phase: Ignition Heater OFF, Auger OFF,
Motor to maximum speed, until stove cold (smoke
ACTIONS TAKEN Smoke
temperature below threshold of "Smoke Temperat." in
LIGHTING OFF submenu)
USER RESET Display knob depressed for 5s
DISPLAY SAVED TO EVENTS LOG "CHIMNEY OBSTR."
(INTERNAL MEMORY)
SHOWN ON DISPLAY (SCROLLING) "SMOKE MOTOR KO"
ABNORMAL DESCRIPTION Smoke Motor blocked (delayed alarm)
ACTIONS TAKEN During the Alarm phase: Ignition heater OFF, Auger OFF
USER RESET Display knob depressed for 5s
DISPLAY SAVED TO EVENTS LOG "SMOKE M BLOCKED"
(INTERNAL MEMORY)
41 USER MANUAL