Download Controller Manual
Transcript
5 ALARMS AND WARNINGS LIST SHOWN ON DISPLAY (SCROLLING) "SMOKE MOTOR KO" ABNORMAL DESCRIPTION Smoke Motor phases disconnected (delayed alarm) ACTIONS TAKEN During the Alarm phase: Ignition heater OFF, Auger OFF USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG (INTERNAL MEMORY) "SMOKE M DISC." SHOWN ON DISPLAY (SCROLLING) "AMBIENT FAN KO" Fan phases disconnected or Ambient Fan output damaged ABNORMAL DESCRIPTION Ambient (delayed alarm) During the Alarm phase: Ignition Heater OFF, Auger OFF, Smoke ACTIONS TAKEN Motor to maximum speed, until stove cold (smoke temperature below threshold of "Smoke Temperat." in LIGHTING OFF submenu) USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG "AIR MOTOR KO" (INTERNAL MEMORY) SHOWN ON DISPLAY (SCROLLING) "IGNITION HEATER KO" Heater disconnected or Ignition Heater output ABNORMAL DESCRIPTION Ignition damaged (delayed alarm) During the Alarm phase: Ignition Heater OFF, Auger OFF, Motor to maximum speed, until stove cold (smoke ACTIONS TAKEN Smoke temperature below threshold of "Smoke Temperat." in LIGHTING OFF submenu) USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG "IGNIT. HEAT. KO" (INTERNAL MEMORY) SHOWN ON DISPLAY (SCROLLING) "AUGER KO" phases disconnected or Auger damaged ABNORMAL DESCRIPTION Auger (delayed alarm) ACTIONS TAKEN All loads are disconnected (Safety Relay open) USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG "AUGER KO" (INTERNAL MEMORY) SHOWN ON DISPLAY (SCROLLING) SMOKE PROBE KO ABNORMAL DESCRIPTION Smoke Probe fault in Working phase the Alarm phase: Smoke Motor OFF, Ambient Fan OFF, ACTIONS TAKEN During Ignition Heater OFF, Auger OFF USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG "SMOKE PROBE KO" (INTERNAL MEMORY) SHOWN ON DISPLAY (SCROLLING) "ELECTRONIC BOARD KO" ABNORMAL DESCRIPTION Communication loss to Control Unit internal bus ACTIONS TAKEN All loads are disconnected (Safety Relay open) USER RESET Display knob depressed for 5s DISPLAY SAVED TO EVENTS LOG "ELECTRONIC KO" (INTERNAL MEMORY) 43 USER MANUAL