EntelliGuard® G Circuit Breaker Application Guide Section 5. Catalog Numbering Guide DET-653A 02 Apr 09 Digit 13 – Bell Alarm/Trip Annunciation Bell Alarm and Trip Annunciation Bell Alarm Contact (1NO/1NC) with Lockout (BACL) Mechanical Operations Counter (MOC) Bell Alarm Contact (1NO/1NC) with Lockout and MOC RTC Power Rated Contacts on SD* RTC Signal Rated (Hi-Fi) Contacts on SD* RTC Signal Rated (Hi-Fi) Contacts through Trip Unit** BACL and RTC Power Rated Contacts on SD* BACL and RTC Signal Rated (Hi-Fi) Contacts on SD* BACL and RTC Signal Rated (Hi-Fi) through Trip Unit** BACL, MOC and RTC Power Rated on SD* BACL, MOC and RTC Signal Rated on SD* BACL, MOC and RTC Signal Rated (Hi-Fi) through Trip Unit** MOC and RTC Power Rated on SD* MOC and RTC Signal Rated on SD* MOC and RTC Signal Rated (Hi-Fi) through Trip Unit** Blank/none BACL = Bell Alarm Contact with Lockout RTC = Ready To Close Contacts Code A B C 1 2 3 D E F G H Digit 15 – Mechanical Interlocks Mechanical Interlocks Blank/None DEFAULT Mechanical Interlock - Type A Mechanical Interlock - Type B Mechanical Interlock - Type C Mechanical Interlock - Type D Code X 1 2 3 4 • Some installations use multiple power sources that are required to supply energy simultaneously, alternately, or, in a specified sequence. EntelliGuard G Circuit Breakers can be used to interconnect these sources and be electrically and mechanically interlocked to provide the necessary transition and protection. Mechanical Interlocks are available for fixed and J draw out circuit breakers. The interlocks enable directly interlocking K L M X breakers that are mounted side by side or in vertical stacks. The interlocks Hi-Fi = High Fidelity SD = Secondary Disconnect **In order to output the RTC contact output via Trip Unit (options 3, F, J, consist of two components: (A) The factory-installed bracket fitted to the breaker (fixed breakers) or the cassette (drawout breakers), and (B) The field-installable interconnecting cables available in lengths of 1.0, 1.6, 2.0, 2.5, 3.0, 3.5 and 4.0m (ordered separately). Refer to Section 4 for interlocking schemes. • Contact factory for availability. M) a communications package must be selected in Advanced Features (Code 19/Step 16); this requires Secondary Disconnect Block B. **If a UL or ANSI Switch is selected, the (Hi-Fi Through Trip Unit) is not valid (Options 3, F, J, M). **RTC Through the Trip Unit is not a valid option for Switches. Bell Alarm Contact with Lockout comes with the Trip Unit set to Manual LO Enabled. • The term “Hi-Fi” refers to gold-plated contacts use for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125vac). • Option "B", “I”, “2”, “3”, “K”, “L”, “M”, and “X” are the only valid options when a Switch is selected in Digit 2. Digit 14 – Key Interlock Key Interlock (Breaker Mounted) Castell Key Interlock Kirk Key Interlock Ronis Key Interlock Pushbutton Padlock Device Castell Key Interlock and Push Button Padlock Device Kirk Key Interlock and Push Button Padlock Device Ronis Key Interlock and Push Button Padlock Device Blank/none Code C K R L 1 2 3 X • This option provides factory installed interlocking devices for installation between separate circuit breakers (baseplates and mechanism). This safeguard ensures that a circuit breaker cannot be closed unless the dedicated key has been inserted and secured within the lock. • If selecting a Draw Out Breaker (Digit 6), consider putting the Key Interlock on the Cassette versus the breaker. This enables the ability to swap breakers without having to change the key interlocks. • Locks and Keys are NOT Supplied by GE. 46 ® 2009 General Electric All Rights Reserved