Download section 1 - Artisan Technology Group

Transcript
ANCOT Corporation
User=s Manual
SCSI Bus Analyzer Ultra-2000: Section 3
SCSI COMMAND PROFILE
Trace Address
IDs
Command Code
Data Transferred
Arb/Sel:
ID Msg:
Command:
Data:
Status:
End Msg:
Cmd Total:
:
:
:
:
00040 - 0025B
I7 -> T0
08 Read/Rcv
512 Bytes
71 600 ns
93 920 ns
300 560 ns
735 600 ns
286 360 ns
398 480 ns
────────────
1 886 520 ns
3.7%
4.9%
15.9%
38.9%
15.1%
21.1%
The following definitions of phases are used in calculating the timing:
Arb/Sel
: from the assertion of BSY to the first event in
Message-Out (for the Identify message).
ID Msg
: from the start of Message-Out phase to the first event w
which is neither Message-Out nor Message-In phase.
Command
: from the first event in the Command phase to the first
event not in Command phase.
Data
: from the first event of either Data-In or Data-Out phase
to the first event after the last event in the same
phase, after subtracting any disconnect time.
Status
: from the first event in Status phase to the first event
not in Status phase.
End Msg
: from the first event in the last Message-In phase of this
command to the release of BSY (Bus Free).
Disconnect
: from start of Message-In phase for any disconnect message
to the end of Message-In phase for the Identify message
after reconnect. All such periods within this command are
added together.
53
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com