1.2
Converting from NEMA Format to RBC
Previous versions of VISSIM included the NEMA signal controller type. The VISSIM Ring Barrier
Controller (RBC) replaces the need for the NEMA signal controller. Through VISSIM Version 5.20,
both types of controllers will be available for simulation; however, beginning with VISSIM Version
5.30, the NEMA controller will no longer be available. As such, it is necessary to convert any NEMA
signal controller types (*.nse file type) in VISSIM to the RBC format (*.rbc).
To convert from NEMA to RBC, VISSIM users have two options:
Option 1: Convert a single NEMA signal controller to RBC:
In the Signal Control dialogue box, select the signal controller to change from the list on the
left and use the drop-down menu on the right to change type to Ring Barrier Controller and
click OK.
This will result in a *.rbc file being created in the project directory with the same file name
as the previous *.nse file. In addition, the Program File and Dialog DLL file reference will
update to reflect the RBC controller type.
Option 2: Convert all NEMA signal controllers in a network to RBC:
Under the Signal Control menu, select “Convert NEMA to RBC”.
This will create *.rbc files for all *.nse files in the network. In the Signal Control dialogue
box, all signal control types that were NEMA will now be changed to type Ring Barrier
Controller.
This conversion process will only convert the signal timing and detector parameters. Transit
signal priority (TSP) and railroad pre-emption parameters do not automatically convert but can
be manually transferred to the RBC by the user.