INSTALLING VCA COMPONENTS
Mirasys provides configuration services for the VCA functionality;
for further information, please contact Mirasys.
This section of the manual only covers installing basic VCA functionality.
Please refer to Mirasys VMS VCA Configuration Guide for more information
on using VCA with Mirasys products.
Mirasys VMS supports both analog and IP based VCA services. The VCA
functionality allows using VCA metadata for creating alarms based on
metadata information. This functionality requires separate licensing (see
below).
If you are using the VCA functionality through analog capture cards, please
see Supported capture cards for analog VCA for a list of supported capture
cards.
Installing VCA components to a Mirasys VMS system requires the following
steps:
1.
Installing a database to each Mirasys VMS recorder with VCA streams
2.
Adding the license keys:
a.
Adding VCA channel license keys to each recorder with VCA
streams
b.
Adding capture card / IP capture specific licenses to each
recorder with VCA streams
3.
Configuring the VCA cameras
4.
Configuring alarm events based on VCA messages in System Manager
These steps are further discussed below.
IMPORTANT: It is important to note that the licenses and the database are
recorder specific and need to be installed on the recorder(s) on which the
VCA feeds are situated. If a system contains multiple recorders, the licenses
and database must be installed separately on each recorder with VCA feeds.
NOTE: VMS release 7.2.0 comes pre-installed with drivers for VCA
metadata analysis and metadata enrichment. The drivers can be updated
later from system manager application.