4. Offline Adapter Management Utility Command Line Interface
Command Syntax
4. Offline Adapter Management Utility
Command Line Interface
The Offline Adapter Management Utility allows you to configure Emulex adapters
before you install or boot a server operating system.
The Offline Adapter Management Utility includes:


winlpcfg
linlpcfg
You can use the Offline Adapter Management Utility to do the following:










View information on an Emulex adapter
Reset the adapter
Download firmware and boot code files
Select a boot device
Read and update world wide names (WWNs)
Enable boot code
Update configuration regions
Set the adapter to use soft jumpers
Run diagnostic tests
Read and process script files
Command Syntax
In all cases, the commands are given with the prefix os. When you enter any command,
you must replace the os with either:


win – for the WinPE Offline Adapter Management Utility commands for use on
WinPE machines.
./lin – for the Linux Offline Adapter Management Utility commands for use on
Linux and FreeBSD machines.
The Offline Adapter Management Utility commands are not case-sensitive, nor are
their arguments. You can enter them in upper, lower, or mixed case. However, for
Linux operating systems, Emulex recommends using linlpcfg (all lowercase) for the
Offline Adapter Management Utility commands (for example, ./linlpcfg listhba).
The Offline Adapter Management Utility commands require both:


One space between the command name and the first argument.
One space between additional arguments.
Note: Do not put a space before or after the equal sign within an argument.
WWN values are reported and specified with two 4-byte hexadecimal words – WWN
word 0 (w0) and WWN word 1 (w1). Concatenate the w0 and w1 values to make the
full WWN.
Offline and Online Adapter Management Utilities Version 6.3 User Manual
P009408-01A Rev. A
37