Download 8501028 ACEX-FP-IO-XX User`s Manual
Transcript
ACEX-FP-IO-0x COM Express Front Panel Board for Ruggedized/Military Packaging With Support for I/O Mezzanine Board USER’S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom, MI 48393-2417 U.S.A. Tel: (248) 295-0310 Fax: (248) 624-9234 Copyright 2015, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8501028B ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging The information contained in this manual is subject to change without notice. Acromag, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Further, Acromag, Inc. assumes no responsibility for any errors that may appear in this manual and makes no commitment to update, or keep current, the information contained in this manual. No part of this manual may be copied or reproduced in any form, without the prior written consent of Acromag, Inc. IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider the possible adverse effects of power, wiring, component, sensor, or software failures in designing any type of control or monitoring system. This is especially important where economic property loss or human life is involved. It is important that the user employ satisfactory overall system design. It is agreed between the Buyer and Acromag, that this is the Buyer's responsibility. Acromag, Inc. Tel: 248-295-0310 -2- www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Table of Contents 1.0 General Information ....................................................................................... 5 Key Features ................................................................................................................................... 6 2.0 Ordering Information .................................................................................... 6 3.0 Preparation for Use ........................................................................................ 7 Unpacking and Inspecting ................................................................................................................ 7 4.0 Operation ............................................................................................................ 8 Operational Block Diagram .............................................................................................................. 8 ACEX-FP-IO-01 – Board layout ......................................................................................................... 9 ACEX-FP-IO-02 – Board layout ....................................................................................................... 10 ACEX-IO – Board layout .................................................................................................................. 11 Mezzanine Board Interface ............................................................................................................ 13 5.0 Connector Pin-out ........................................................................................ 15 J1 (200 – Pin SEARAY Connector) ................................................................................................... 15 J2 (500 – Pin SEARAY Connector) ................................................................................................... 20 J3 – Keyed-A (130-Pin size #23 38999 Connector) ......................................................................... 33 J4 – Keyed-B (130-Pin size #23 38999 Connector) ......................................................................... 34 J5 – Keyed-C (130-Pin size #23 38999 Connector) ......................................................................... 35 J6 – Keyed-A (6-Pin size #12 38999 Connectors) ........................................................................... 36 J7 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 36 J8 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 37 J9 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 38 J10 (160-Pin SEARAY Mezzanine Connector) ................................................................................. 39 Handling ........................................................................................................................................ 40 ESD Safe Work Area Guidelines ..................................................................................................... 40 6.0 Service and Repair ....................................................................................... 41 Service and Repair Assistance ........................................................................................................ 41 Preliminary Service Procedure ....................................................................................................... 41 Where to Get Help ......................................................................................................................... 41 7.0 Specifications ................................................................................................. 42 Physical........................................................................................................................................... 42 Acromag, Inc. Tel: 248-295-0310 -3- www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Power Requirements...................................................................................................................... 42 Environmental ................................................................................................................................ 42 Appendix...................................................................................................................... 43 500 - Pin SEARAY Connector pin-out by Type ................................................................................ 43 #23, 130 Pin 38999 keyed-B, Peripheral connector pin out (front view) ...................................... 56 #23, 130 Pin 38999 keyed-A and C, I/O connector pin out (front view) ........................................ 57 38999 Crimping Tools .................................................................................................................... 58 PCB Mechanical Drawings .............................................................................................................. 59 Bill of Materials .............................................................................................................................. 61 Schematic ....................................................................................................................................... 61 Mezzanine Board Installation......................................................................................................... 62 Certificate of Volatility .......................................................................................... 64 Revision History ....................................................................................................... 65 Acromag, Inc. Tel: 248-295-0310 -4- www.acromag.com ACEX-FP-IO-0x User’s Manual 1.0 COM Express Front Panel for Ruggedized/Military Packaging General Information The ACEX-FP-IO-0x is a front panel board that provides the I/O interface for the ARCX-4xxx product family via the 38999 type connections. The ACEX-FP-IO-0x board connects to the ACEX-46xx Carrier via high-speed, high-density ruggedized SEARAY connector. The signals are then passed thru to the XCOM-6400 CPU module via COM Express connector. The ACEX-FP-IO-0x front panel boards supports the use of custom mezzanine modules through the use of ultra-high-density SEARAY connectors. Models: ACEX-FP-IO-01 (Single wide) Two high-density 130-pin circular 38999 type connectors o One Peripheral I/O o One PMC/XMC rear I/O One 6-Pin circular 38999 type connectors o Power input o Power On switch ACEX-FP-IO-02 (Double wide) Three high-density 130-pin circular 38999 type connectors o One Peripheral I/O o Two PMC/XMC rear I/O One 6-Pin circular 38999 type connectors o Power input o Power On switch Note: Single wide / Double wide refers to the number of supported PMC/XMC rear I/O slots available which is determined by the use of a single wide or double wide ACEX-46xx Carrier board. i.e. the double wide carrier board has two PMC/XMC expansion sites available. The XMC rear I/O supports the UD (user defined) signals as defined in the ANSI/VITA 42.0 specifications. The DPxx+ and DPxx- signals are not brought out the 130-Pin 38999 connector. Acromag, Inc. Tel: 248-295-0310 -5- www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Key Features Provides access to standard peripherals of the Type 6 COM Express CPU through high-density ruggedized connector. o Two HDMI/DVI ports o One VGA port o Three USB 2.0 Ports o Two RS-232/422/485 Communication ports o One SATA port o Two Gigabit Ethernet Ports o Audio (One Line in and One Line out) o Fault/Status LED Provides Rear I/O connections to PMC/XMC expansion cards on the ACEX-46xx carrier through high-density ruggedized connector(s). Supports the use of mezzanine modules that interface between the system and the PMC/XMC Rear I/O 38999 connectors. Designed to meet requirements of MIL-STD-810F environmental specification. 2.0 Ordering Information ACEX-FP-IO-xx xx = ACEX-IO 01 = Single Wide – Supports one PMC/XMC Rear I/O sites 02 = Double Wide – Supports two PMC/XMC Rear I/O sites Pass-through Mezzanine Board Front Panel Accessories (optional) 5028-556 38999 #23 size , CPU I/O Peripheral Breakout Cable 5028-557 38999 #12 size , Power Cable 5028-558 38999 #23 size Keyed “A” mating cable connector only 5028-559 38999 #23 size Keyed “C” mating cable connector only 5028-560 38999 #23 size Keyed “B” mating cable connector only 5028-561 38999 #12 size Keyed A mating cable connector only 5028-566 38999 #23 size, PMC/XMC Site 1 Rear I/O Breakout Cable 5028-567 38999 #23 size, PMC/XMC Site 2 Rear I/O Breakout Cable Note: 5028-566 and 5028-567 cables intended for use with two 5025-288 SCSI-3 termination panels Acromag, Inc. Tel: 248-295-0310 -6- www.acromag.com ACEX-FP-IO-0x User’s Manual 3.0 COM Express Front Panel for Ruggedized/Military Packaging Preparation for Use Unpacking and Inspecting Upon receipt of this product, inspect the shipping carton for evidence of mishandling during transit. If the shipping carton is badly damaged or water stained, request that the carrier's agent be present when the carton is opened. If the carrier's agent is absent when the carton is opened and the contents of the carton are damaged, keep the carton and packing material for the agent's inspection. WARNING: This board utilizes static sensitive components and should only be handled at a static-safe workstation. Acromag, Inc. Tel: 248-295-0310 For repairs to a product damaged in shipment, refer to the Acromag Service Policy to obtain return instructions. It is suggested that salvageable shipping cartons and packing material be saved for future use in the event the product must be shipped. This board is physically protected with packing material and electrically protected with an anti-static bag during shipment. However, it is recommended that the board be visually inspected for evidence of mishandling prior to applying power. -7- www.acromag.com ACEX-FP-IO-0x User’s Manual 4.0 COM Express Front Panel for Ruggedized/Military Packaging Operation Operational Block Diagram Acromag, Inc. Tel: 248-295-0310 -8- www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging ACEX-FP-IO-01 – Board layout Acromag, Inc. Tel: 248-295-0310 -9- www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging ACEX-FP-IO-02 – Board layout Acromag, Inc. Tel: 248-295-0310 - 10 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging ACEX-IO – Board layout Acromag, Inc. Tel: 248-295-0310 - 11 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J3 is a 130-pin size #23 38999 type connector, keyed – A. This connector provides access to the Rear I/O coming from the PMC/XMC site on the carrier board (ACEX-46xx). If a PMC P4/J4 connector is used/installed in site 1 on the carrier board than all 32 differential Pairs of Rear I/O signals are available thru J3. If an XMC card P15 connector is used/installed in site 1 of the carrier board than the UD (user defined signals) Row C and F of the XMC boards P16 connector as defined in VITA 42.0 signals are available. J4 is a 130-pin size #23 38999 type connector, keyed – B. This connector provides the following standard peripheral I/O as shown below. Optional cable 5028-556 is available. Acromag, Inc. Tel: 248-295-0310 - 12 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J5 is a 130-pin size #23 38999 type connector, Keyed – C. This connector provides access to the Rear I/O coming from the PMC/XMC site on the carrier board (ACEX-46xx). If a PMC P4/J4 connector is used/installed in site 2 on the carrier board than all 32 differential Pairs of Rear I/O signals are available thru J3. If an XMC card P15 connector is used/installed in site 2 of the carrier board than the UD (user defined signals) Row C and F of the XMC boards P16 connector as defined in VITA 42.0 signals are available. J6 is a 6-pin size #12 38999 type connector, keyed - A. This connector is used to provide External input power 10V to 36VDC to the Carrier (ACEX-46xx). This connector also provides PWR_BTN line to allow the user to use a power switch. Optional cable 5028-557 is available. J7 and J8 are high-density connectors that provide the mezzanine board interface for 38999 connector J3. The PMC/XMC Rear I/O signals from Site 1 on the carrier board (ACEX-46xx) are routed up to the mezzanine interface on J8 and then back down on J7 before being sent out the 38999 connector J3. The ACEX-FP-IO-0x boards require the use of a mezzanine board on J7/J8 in order to provide connections for the signals being routed to the 38999 connector J3. A “pass-through” mezzanine board is included on standard models that allow the PMC/XMC Rear I/O signals to be routed directly out the 38999 connector J3. A design kit for developing custom mezzanine boards is available upon request. J9 and J10 are high-density connectors that provide the mezzanine board interface for 38999 connector J5. The PMC/XMC Rear I/O signals from Site 2 on the carrier board (ACEX-46xx) are routed up to the mezzanine interface on J10 and then back down on J9 before being sent out the 38999 connector J5. The ACEX-FP-IO-0x boards require the use of a mezzanine board on J9/J10 in order to provide connections for the signals being routed to the 38999 connector J5. A “pass-through” mezzanine board is included on standard models that allow the PMC/XMC Rear I/O signals to be routed directly out the 38999 connector J5. A design kit for developing custom mezzanine boards is available upon request. Mezzanine Board Interface The ACEX-FP-IO-0x boards require the use of a mezzanine board on J7/J8 and J9/J10 in order to provide connections for the signals being routed to the corresponding 38999 connectors J3 and J5, respectively. On standard models, a “pass-through” mezzanine board is included for each of the mezzanine board sites on the ACEX-FP-IO-0x boards. The “pass-through” mezzanine board simply routes the PMC/XMC Rear I/O signals straight through to the 38999 connector. The “pass-through” mezzanine board is designed to be interchangeable between the two mezzanine board sites. In addition to the core set of PMC/XMC Rear I/O signals that are identical between the two sites, there are a set of signals unique to each of the mezzanine board sites. On the J7/J8 mezzanine board (Site 1) there are a variety of miscellaneous signals are available for use on custom mezzanine boards. These include PCIe lanes, a SATA interface, GPIO signals, and I2C Bus lines. On the J9/J10 mezzanine board (Site 2) the additional pins are used to bring up the rest of the PMC/XMC Rear I/O signals for use on custom mezzanine boards. Acromag, Inc. Tel: 248-295-0310 - 13 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Power LED The Blue Power LED indicates DC 10V-36V power is applied at the external power input. Status LED The Status LED is Bi-color (RED/GREEN) LED that is used to show the status of the system power state S3 and S4. System Power State S3 the Sleep state: All power is off except memory. If power is removed at this point you will lose your current session. System Power State S4 the Hibernate state: Safe to remove power, will always resume the current session when power is reapplied. S3# and S4# are active low signals (# indicates active low). There are three basic states indicated by the Status LED: Status LED steady “Green On” when the system is running. Status LED “Blink Green” when the system enters sleep state S3. Status LED will turn off when the system enters Sleep state S4 Hibernate. Note: It is ok to remove power from the system when the Status LED is off. Signal Activity Sleep S3# Sleep S4# 0 0 1 0 1 1 Status LED Green On Blink Green LED Off - Condition of the Status LED 0 - Represents a Low state 1 - Represents a High state Note: S5 State is not monitored by the LED however the Status LED will go off during a S5 or shutdown condition. SW2 – Reserved SW2 is reserved for future use. SW2 - Bold indicates default factory settings SW2 - 1 ON Reserved OFF Normal operation SW2 - 2 ON Reserved OFF Normal operation SW2 - 3 ON Reserved OFF Normal operation SW2 - 4 ON Reserved OFF Normal operation Acromag, Inc. Tel: 248-295-0310 - 14 - www.acromag.com ACEX-FP-IO-0x User’s Manual 5.0 COM Express Front Panel for Ruggedized/Military Packaging Connector Pin-out J1 (200 – Pin SEARAY Connector) Signal Name VCC_5V_IN J24_RIO3_P J24_RIO3_N J24_RIO7_P J24_RIO7_N J24_RIO10_P J24_RIO10_N J24_RIO14_P J24_RIO14_N J24_RIO17_P J24_RIO17_N J24_RIO21_P J24_RIO21_N J24_RIO24_P J24_RIO24_N J24_RIO28_P J24_RIO28_N J24_RIO31_P J24_RIO31_N EXT_PWR_OUT J24_RIO1_P J24_RIO1_N J24_RIO5_P J24_RIO5_N J24_RIO8_P J24_RIO8_N J24_RIO12_P J24_RIO12_N J24_RIO15_P J24_RIO15_N J24_RIO19_P J24_RIO19_N J24_RIO22_P J24_RIO22_N J24_RIO26_P J24_RIO26_N Description 5V Input Voltage PMC Site 2 Rear I/O Differential Pair "J24_RIO3+" PMC Site 2 Rear I/O Differential Pair "J24_RIO3-" PMC Site 2 Rear I/O Differential Pair "J24_RIO7+" PMC Site 2 Rear I/O Differential Pair "J24_RIO7-" PMC Site 2 Rear I/O Differential Pair "J24_RIO10+" PMC Site 2 Rear I/O Differential Pair "J24_RIO10-" PMC Site 2 Rear I/O Differential Pair "J24_RIO14+" PMC Site 2 Rear I/O Differential Pair "J24_RIO14-" PMC Site 2 Rear I/O Differential Pair "J24_RIO17+" PMC Site 2 Rear I/O Differential Pair "J24_RIO17-" PMC Site 2 Rear I/O Differential Pair "J24_RIO21+" PMC Site 2 Rear I/O Differential Pair "J24_RIO21-" PMC Site 2 Rear I/O Differential Pair "J24_RIO24+" PMC Site 2 Rear I/O Differential Pair "J24_RIO24-" PMC Site 2 Rear I/O Differential Pair "J24_RIO28+" PMC Site 2 Rear I/O Differential Pair "J24_RIO28-" PMC Site 2 Rear I/O Differential Pair "J24_RIO31+" PMC Site 2 Rear I/O Differential Pair "J24_RIO31-" External Output Power PMC Site 2 Rear I/O Differential Pair "J24_RIO1+" PMC Site 2 Rear I/O Differential Pair "J24_RIO1-" PMC Site 2 Rear I/O Differential Pair "J24_RIO5+" PMC Site 2 Rear I/O Differential Pair "J24_RIO5-" PMC Site 2 Rear I/O Differential Pair "J24_RIO8+" PMC Site 2 Rear I/O Differential Pair "J24_RIO8-" PMC Site 2 Rear I/O Differential Pair "J24_RIO12+" PMC Site 2 Rear I/O Differential Pair "J24_RIO12-" PMC Site 2 Rear I/O Differential Pair "J24_RIO15+" PMC Site 2 Rear I/O Differential Pair "J24_RIO15-" PMC Site 2 Rear I/O Differential Pair "J24_RIO19+" PMC Site 2 Rear I/O Differential Pair "J24_RIO19-" PMC Site 2 Rear I/O Differential Pair "J24_RIO22+" PMC Site 2 Rear I/O Differential Pair "J24_RIO22-" PMC Site 2 Rear I/O Differential Pair "J24_RIO26+" PMC Site 2 Rear I/O Differential Pair "J24_RIO26-" Acromag, Inc. Tel: 248-295-0310 - 15 - SEARAY Pin A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 www.acromag.com ACEX-FP-IO-0x User’s Manual J24_RIO29_P J24_RIO29_N RSVD EXT_PWR_OUT VCC_3.3V_IN J24_RIO2_P J24_RIO2_N J24_RIO6_P J24_RIO6_N J24_RIO9_P J24_RIO9_N J24_RIO13_P J24_RIO13_N J24_RIO16_P J24_RIO16_N J24_RIO20_P J24_RIO20_N J24_RIO23_P J24_RIO23_N J24_RIO27_P J24_RIO27_N J24_RIO30_P J24_RIO30_N VCC_12V_IN J24_RIO0_P J24_RIO0_N J24_RIO4_P J24_RIO4_N J26_SIO4_P J26_SIO4_N J24_RIO11_P J24_RIO11_N J26_SIO8_P J26_SIO8_N J24_RIO18_P J24_RIO18_N J26_SIO12_P J26_SIO12_N J24_RIO25_P J24_RIO25_N J26_SIO16_P COM Express Front Panel for Ruggedized/Military Packaging PMC Site 2 Rear I/O Differential Pair "J24_RIO29+" PMC Site 2 Rear I/O Differential Pair "J24_RIO29-" Reserved External Output Power 3.3V Input Voltage PMC Site 2 Rear I/O Differential Pair "J24_RIO2+" PMC Site 2 Rear I/O Differential Pair "J24_RIO2-" PMC Site 2 Rear I/O Differential Pair "J24_RIO6+" PMC Site 2 Rear I/O Differential Pair "J24_RIO6-" PMC Site 2 Rear I/O Differential Pair "J24_RIO9+" PMC Site 2 Rear I/O Differential Pair "J24_RIO9-" PMC Site 2 Rear I/O Differential Pair "J24_RIO13+" PMC Site 2 Rear I/O Differential Pair "J24_RIO13-" PMC Site 2 Rear I/O Differential Pair "J24_RIO16+" PMC Site 2 Rear I/O Differential Pair "J24_RIO16-" PMC Site 2 Rear I/O Differential Pair "J24_RIO20+" PMC Site 2 Rear I/O Differential Pair "J24_RIO20-" PMC Site 2 Rear I/O Differential Pair "J24_RIO23+" PMC Site 2 Rear I/O Differential Pair "J24_RIO23-" PMC Site 2 Rear I/O Differential Pair "J24_RIO27+" PMC Site 2 Rear I/O Differential Pair "J24_RIO27-" PMC Site 2 Rear I/O Differential Pair "J24_RIO30+" PMC Site 2 Rear I/O Differential Pair "J24_RIO30-" 12V Input Voltage PMC Site 2 Rear I/O Differential Pair "J24_RIO0+" PMC Site 2 Rear I/O Differential Pair "J24_RIO0-" PMC Site 2 Rear I/O Differential Pair "J24_RIO4+" PMC Site 2 Rear I/O Differential Pair "J24_RIO4-" XMC Site 2 Rear I/O Differential Pair "J26_SIO4+" XMC Site 2 Rear I/O Differential Pair "J26_SIO4-" PMC Site 2 Rear I/O Differential Pair "J24_RIO11+" PMC Site 2 Rear I/O Differential Pair "J24_RIO11-" XMC Site 2 Rear I/O Differential Pair "J26_SIO8+" XMC Site 2 Rear I/O Differential Pair "J26_SIO8-" PMC Site 2 Rear I/O Differential Pair "J24_RIO18+" PMC Site 2 Rear I/O Differential Pair "J24_RIO18-" XMC Site 2 Rear I/O Differential Pair "J26_SIO12+" XMC Site 2 Rear I/O Differential Pair "J26_SIO12-" PMC Site 2 Rear I/O Differential Pair "J24_RIO25+" PMC Site 2 Rear I/O Differential Pair "J24_RIO25-" XMC Site 2 Rear I/O Differential Pair "J26_SIO16+" Acromag, Inc. Tel: 248-295-0310 - 16 - B17 B18 B19 B20 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 www.acromag.com ACEX-FP-IO-0x User’s Manual J26_SIO16_N RSVD VCC_12V_IN VCC_3.3V_IN J26_SIO1_P J26_SIO1_N J26_SIO3_P J26_SIO3_N J26_SIO5_P J26_SIO5_N J26_SIO7_P J26_SIO7_N J26_SIO9_P J26_SIO9_N J26_SIO11_P J26_SIO11_N J26_SIO13_P J26_SIO13_N J26_SIO15_P J26_SIO15_N J26_SIO17_P J26_SIO17_N VCC_5V_IN J26_SIO0_P J26_SIO0_N GND GND J26_SIO2_P J26_SIO2_N GND GND J26_SIO6_P J26_SIO6_N GND GND J26_SIO10_P J26_SIO10_N GND GND J26_SIO14_P J26_SIO14_N COM Express Front Panel for Ruggedized/Military Packaging XMC Site 2 Rear I/O Differential Pair "J26_SIO16-" Reserved 12V Input Voltage 3.3V Input Voltage XMC Site 2 Rear I/O Differential Pair "J26_SIO1+" XMC Site 2 Rear I/O Differential Pair "J26_SIO1-" XMC Site 2 Rear I/O Differential Pair "J26_SIO3+" XMC Site 2 Rear I/O Differential Pair "J26_SIO3-" XMC Site 2 Rear I/O Differential Pair "J26_SIO5+" XMC Site 2 Rear I/O Differential Pair "J26_SIO5-" XMC Site 2 Rear I/O Differential Pair "J26_SIO7+" XMC Site 2 Rear I/O Differential Pair "J26_SIO7-" XMC Site 2 Rear I/O Differential Pair "J26_SIO9+" XMC Site 2 Rear I/O Differential Pair "J26_SIO9-" XMC Site 2 Rear I/O Differential Pair "J26_SIO11+" XMC Site 2 Rear I/O Differential Pair "J26_SIO11-" XMC Site 2 Rear I/O Differential Pair "J26_SIO13+" XMC Site 2 Rear I/O Differential Pair "J26_SIO13-" XMC Site 2 Rear I/O Differential Pair "J26_SIO15+" XMC Site 2 Rear I/O Differential Pair "J26_SIO15-" XMC Site 2 Rear I/O Differential Pair "J26_SIO17+" XMC Site 2 Rear I/O Differential Pair "J26_SIO17-" 5V Input Voltage XMC Site 2 Rear I/O Differential Pair "J26_SIO0+" XMC Site 2 Rear I/O Differential Pair "J26_SIO0-" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_SIO2+" XMC Site 2 Rear I/O Differential Pair "J26_SIO2-" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_SIO6+" XMC Site 2 Rear I/O Differential Pair "J26_SIO6-" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_SIO10+" XMC Site 2 Rear I/O Differential Pair "J26_SIO10-" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_SIO14+" XMC Site 2 Rear I/O Differential Pair "J26_SIO14-" Acromag, Inc. Tel: 248-295-0310 - 17 - D18 D19 D20 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 www.acromag.com ACEX-FP-IO-0x User’s Manual J26_SIO18_P J26_SIO18_N GND GND J26_DP17_N J26_DP17_P GND GND J26_DP13_N J26_DP13_P GND GND J26_DP09_N J26_DP09_P GND GND J26_DP05_N J26_DP05_P GND GND J26_DP01_N J26_DP01_P J26_DP19_N J26_DP19_P GND GND J26_DP15_N J26_DP15_P GND GND J26_DP11_N J26_DP11_P GND GND J26_DP07_N J26_DP07_P GND GND J26_DP03_N J26_DP03_P GND COM Express Front Panel for Ruggedized/Military Packaging XMC Site 2 Rear I/O Differential Pair "J26_SIO18+" XMC Site 2 Rear I/O Differential Pair "J26_SIO18-" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP17-" XMC Site 2 Rear I/O Differential Pair "J26_DP17+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP13-" XMC Site 2 Rear I/O Differential Pair "J26_DP13+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP09-" XMC Site 2 Rear I/O Differential Pair "J26_DP09+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP05-" XMC Site 2 Rear I/O Differential Pair "J26_DP05+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP01-" XMC Site 2 Rear I/O Differential Pair "J26_DP01+" XMC Site 2 Rear I/O Differential Pair "J26_DP19-" XMC Site 2 Rear I/O Differential Pair "J26_DP19+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP15-" XMC Site 2 Rear I/O Differential Pair "J26_DP15+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP11-" XMC Site 2 Rear I/O Differential Pair "J26_DP11+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP07-" XMC Site 2 Rear I/O Differential Pair "J26_DP07+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP03-" XMC Site 2 Rear I/O Differential Pair "J26_DP03+" Ground Acromag, Inc. Tel: 248-295-0310 - 18 - F19 F20 G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 G19 G20 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 www.acromag.com ACEX-FP-IO-0x User’s Manual GND GND GND J26_DP16_N J26_DP16_P GND GND J26_DP12_N J26_DP12_P GND GND J26_DP08_N J26_DP08_P GND GND J26_DP04_N J26_DP04_P GND GND J26_DP00_N J26_DP00_P J26_DP18_N J26_DP18_P GND GND J26_DP14_N J26_DP14_P GND GND J26_DP10_N J26_DP10_P GND GND J26_DP06_N J26_DP06_P GND GND J26_DP02_N J26_DP02_P GND GND COM Express Front Panel for Ruggedized/Military Packaging Ground Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP16-" XMC Site 2 Rear I/O Differential Pair "J26_DP16+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP12-" XMC Site 2 Rear I/O Differential Pair "J26_DP12+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP08-" XMC Site 2 Rear I/O Differential Pair "J26_DP08+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP04-" XMC Site 2 Rear I/O Differential Pair "J26_DP04+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP00-" XMC Site 2 Rear I/O Differential Pair "J26_DP00+" XMC Site 2 Rear I/O Differential Pair "J26_DP18-" XMC Site 2 Rear I/O Differential Pair "J26_DP18+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP14-" XMC Site 2 Rear I/O Differential Pair "J26_DP14+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP10-" XMC Site 2 Rear I/O Differential Pair "J26_DP10+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP06-" XMC Site 2 Rear I/O Differential Pair "J26_DP06+" Ground Ground XMC Site 2 Rear I/O Differential Pair "J26_DP02-" XMC Site 2 Rear I/O Differential Pair "J26_DP02+" Ground Ground Acromag, Inc. Tel: 248-295-0310 - 19 - H20 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 J17 J18 J19 J20 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 K15 K16 K17 K18 K19 K20 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J2 (500 – Pin SEARAY Connector) Signal Name GND J14_RIO19_N J14_RIO19_P J14_RIO24_P J14_RIO24_N J14_RIO20_N J14_RIO20_P J14_RIO21_N J14_RIO21_P J14_RIO23_P J14_RIO23_N J14_RIO25_P J14_RIO25_N J14_RIO27_P J14_RIO27_N J14_RIO29_P J14_RIO29_N J14_RIO31_P J14_RIO31_N VCC_12V_IN USB0_+5V FAN_TACH FAN_PWM PLT_RST# USB3_+5V EDP_HPD EDP_BKLTCTL EDP_BKLTEN USB4_+5V EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT EXT_PWR_OUT Description Ground PMC Site 1 Rear I/O Differential Pair "J14_RIO19-" PMC Site 1 Rear I/O Differential Pair "J14_RIO19+" PMC Site 1 Rear I/O Differential Pair "J14_RIO24+" PMC Site 1 Rear I/O Differential Pair "J14_RIO24-" PMC Site 1 Rear I/O Differential Pair "J14_RIO20-" PMC Site 1 Rear I/O Differential Pair "J14_RIO20+" PMC Site 1 Rear I/O Differential Pair "J14_RIO21-" PMC Site 1 Rear I/O Differential Pair "J14_RIO21+" PMC Site 1 Rear I/O Differential Pair "J14_RIO23+" PMC Site 1 Rear I/O Differential Pair "J14_RIO23-" PMC Site 1 Rear I/O Differential Pair "J14_RIO25+" PMC Site 1 Rear I/O Differential Pair "J14_RIO25-" PMC Site 1 Rear I/O Differential Pair "J14_RIO27+" PMC Site 1 Rear I/O Differential Pair "J14_RIO27-" PMC Site 1 Rear I/O Differential Pair "J14_RIO29+" PMC Site 1 Rear I/O Differential Pair "J14_RIO29-" PMC Site 1 Rear I/O Differential Pair "J14_RIO31+" PMC Site 1 Rear I/O Differential Pair "J14_RIO31-" 12V Input Voltage USB0 Positive 5V from Carrier CPU Fan TACH Input CPU Fan Speed Control Platform Reset Signal USB3 Positive 5V from Carrier eDP Hot Plug Detect eDP Backlight Brightness Control eDP Backlight Enable USB4 Positive 5V from Carrier External Output Power External Output Power External Output Power External Output Power External Output Power External Output Power External Output Power External Output Power External Output Power Acromag, Inc. Tel: 248-295-0310 - 20 - SEARAY Pin A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 www.acromag.com ACEX-FP-IO-0x User’s Manual EXT_PWR_OUT VCC_5V_IN GND LINE-OUT_R AUDIO_GND LINE-IN_R LINE-IN_L GND GBE0_MDI3_P GBE0_MDI3_N GBE1_MDI3_P GBE1_MDI3_N J14_RIO18_N J14_RIO18_P J14_RIO14_P J14_RIO14_N J14_RIO7_N J14_RIO7_P J14_RIO10_N J14_RIO10_P J14_RIO6_N J14_RIO6_P J14_RIO17_P J14_RIO17_N J14_RIO22_P J14_RIO22_N J14_RIO26_P J14_RIO26_N J14_RIO8_P J14_RIO8_N GPI_2 GPI_3 USB0_P USB0_N GPO_0 GPO_1 USB3_P USB3_N GND GND USB4_P COM Express Front Panel for Ruggedized/Military Packaging External Output Power 5V Input Voltage Ground Right Channel Audio Line Out from CODEC on Carrier AUDIO_GND connected to Digital GND near CODEC on Carrier Right Channel Audio Line In from CODEC on Carrier Left Channel Audio Line In from CODEC on Carrier Ground Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Negative PMC Site 1 Rear I/O Differential Pair "J14_RIO18-" PMC Site 1 Rear I/O Differential Pair "J14_RIO18+" PMC Site 1 Rear I/O Differential Pair "J14_RIO14+" PMC Site 1 Rear I/O Differential Pair "J14_RIO14-" PMC Site 1 Rear I/O Differential Pair "J14_RIO7-" PMC Site 1 Rear I/O Differential Pair "J14_RIO7+" PMC Site 1 Rear I/O Differential Pair "J14_RIO10-" PMC Site 1 Rear I/O Differential Pair "J14_RIO10+" PMC Site 1 Rear I/O Differential Pair "J14_RIO6-" PMC Site 1 Rear I/O Differential Pair "J14_RIO6+" PMC Site 1 Rear I/O Differential Pair "J14_RIO17+" PMC Site 1 Rear I/O Differential Pair "J14_RIO17-" PMC Site 1 Rear I/O Differential Pair "J14_RIO22+" PMC Site 1 Rear I/O Differential Pair "J14_RIO22-" PMC Site 1 Rear I/O Differential Pair "J14_RIO26+" PMC Site 1 Rear I/O Differential Pair "J14_RIO26-" PMC Site 1 Rear I/O Differential Pair "J14_RIO8+" PMC Site 1 Rear I/O Differential Pair "J14_RIO8-" General Purpose Input 2 General Purpose Input 3 USB0 Differential Pair - "USB0+" USB0 Differential Pair - "USB0-" General Purpose Output 0 General Purpose Output 1 USB3 Differential Pair - "USB3+" USB3 Differential Pair - "USB3-" Ground Ground USB4 Differential Pair - "USB4+" Acromag, Inc. Tel: 248-295-0310 - 21 - A39 A40 A41 A42 A43 A44 A45 A46 A47 A48 A49 A50 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 www.acromag.com ACEX-FP-IO-0x User’s Manual USB4_N USB5_+5V DPC_AUX_SEL UART_TX0_P UART_TX0_N UART_RX0_P UART_RX0_N UART_TX1_P UART_TX1_N UART_RX1_P UART_RX1_N VCC_3.3V_IN LINE-OUT_L VGA_BLU VGA_RED VGA_GRN GND GBE0_MDI2_P GBE0_MDI2_N GBE1_MDI2_P GBE1_MDI2_N WDTO J14_RIO13_N J14_RIO13_P J14_RIO9_N J14_RIO9_P J14_RIO5_N J14_RIO5_P J14_RIO1_N J14_RIO1_P J14_RIO2_N J14_RIO2_P J14_RIO28_P J14_RIO28_N J14_RIO12_N J14_RIO12_P J14_RIO4_P J14_RIO4_N J14_RIO30_P J14_RIO30_N GPI_1 COM Express Front Panel for Ruggedized/Military Packaging USB4 Differential Pair - "USB4-" USB5 Positive 5V from Carrier Digital Display Interface 2 - AUX Function Select General Purpose Serial Port 0 from Carrier Transmitter Positive General Purpose Serial Port 0 from Carrier Transmitter Negative General Purpose Serial Port 0 from Carrier Receiver Positive General Purpose Serial Port 0 from Carrier Receiver Negative General Purpose Serial Port 1 from Carrier Transmitter Positive General Purpose Serial Port 1 from Carrier Transmitter Negative General Purpose Serial Port 1 from Carrier Receiver Positive General Purpose Serial Port 1 from Carrier Receiver Negative 3.3V Input Voltage Left Channel Audio Line Out from CODEC on Carrier Analog Video Output Blue Analog Video Output Red Analog Video Output Green Ground Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Negative Watchdog Timer Output PMC Site 1 Rear I/O Differential Pair "J14_RIO13-" PMC Site 1 Rear I/O Differential Pair "J14_RIO13+" PMC Site 1 Rear I/O Differential Pair "J14_RIO9-" PMC Site 1 Rear I/O Differential Pair "J14_RIO9+" PMC Site 1 Rear I/O Differential Pair "J14_RIO5-" PMC Site 1 Rear I/O Differential Pair "J14_RIO5+" PMC Site 1 Rear I/O Differential Pair "J14_RIO1-" PMC Site 1 Rear I/O Differential Pair "J14_RIO1+" PMC Site 1 Rear I/O Differential Pair "J14_RIO2-" PMC Site 1 Rear I/O Differential Pair "J14_RIO2+" PMC Site 1 Rear I/O Differential Pair "J14_RIO28+" PMC Site 1 Rear I/O Differential Pair "J14_RIO28-" PMC Site 1 Rear I/O Differential Pair "J14_RIO12-" PMC Site 1 Rear I/O Differential Pair "J14_RIO12+" PMC Site 1 Rear I/O Differential Pair "J14_RIO4+" PMC Site 1 Rear I/O Differential Pair "J14_RIO4-" PMC Site 1 Rear I/O Differential Pair "J14_RIO30+" PMC Site 1 Rear I/O Differential Pair "J14_RIO30-" General Purpose Input 1 Acromag, Inc. Tel: 248-295-0310 - 22 - B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 B40 B41 B42 B43 B44 B45 B46 B47 B48 B49 B50 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 www.acromag.com ACEX-FP-IO-0x User’s Manual USB1_+5V EDP_VDDEN EDP_TX3_N EDP_TX3_P GND GND DPC_TX3_N DPC_TX3_P GND GND USB5_P USB5_N DPC_HPD THRMTRIP3# SPKR BATLOW# SUS_STAT# VCC_5V_IN VCC_5V_IN SATA_ACT# VCC_3.3V_IN GND GND GND GND VGA_I2C_DAT GBE0_MDI1_P GBE0_MDI1_N GBE1_MDI1_P GBE1_MDI1_N J14_RIO15_N J14_RIO15_P J14_RIO11_N J14_RIO11_P J16_SIO1_N J16_SIO1_P J14_RIO3_N J14_RIO3_P J16_SIO8_P J16_SIO8_N J14_RIO16_N COM Express Front Panel for Ruggedized/Military Packaging USB1 Positive 5V from Carrier eDP Power Enable eDP Differential Pair 3 Negative eDP Differential Pair 3 Positive Ground Ground Digital Display Interface 2 - Output Differential Pair 3 Negative Digital Display Interface 2 - Output Differential Pair 3 Positive Ground Ground USB5 Differential Pair - "USB5+" USB5 Differential Pair - "USB5-" Digital Display Interface 2 - Hot Plug Detect Output Signal Indicating CPU Entered Thermal Shutdown Audio Enunciator Output - PC Beep Signal Low Battery Indicator for External Battery Imminent Suspend Operation Indicator - Notifies LPC Devices 5V Input Voltage 5V Input Voltage ATA (Parallel and Serial) or SAS Activity Indicator Signal 3.3V Input Voltage Ground Ground Ground Ground Display Data Channel (DDC) Data Line Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Negative PMC Site 1 Rear I/O Differential Pair "J14_RIO15-" PMC Site 1 Rear I/O Differential Pair "J14_RIO15+" PMC Site 1 Rear I/O Differential Pair "J14_RIO11-" PMC Site 1 Rear I/O Differential Pair "J14_RIO11+" XMC Site 1 Rear I/O Differential Pair "J16_SIO1-" XMC Site 1 Rear I/O Differential Pair "J16_SIO1+" PMC Site 1 Rear I/O Differential Pair "J14_RIO3-" PMC Site 1 Rear I/O Differential Pair "J14_RIO3+" XMC Site 1 Rear I/O Differential Pair "J16_SIO8+" XMC Site 1 Rear I/O Differential Pair "J16_SIO8-" PMC Site 1 Rear I/O Differential Pair "J14_RIO16-" Acromag, Inc. Tel: 248-295-0310 - 23 - C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C50 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 www.acromag.com ACEX-FP-IO-0x User’s Manual J14_RIO16_P J16_SIO12_P J16_SIO12_N J14_RIO0_N J14_RIO0_P J16_SIO16_P J16_SIO16_N GPI_0 GPO_3 USB1_P USB1_N GND GND EDP_TX1_N EDP_TX1_P GND GND DPC_TX0_N DPC_TX0_P GND GND DPD_AUX_SEL DPD_HPD COM_THRM# DPB_AUX_SEL DPB_HPD SLP_S5# SLP_S4# SLP_S3# LPC_DRQ1# LPC_DRQ0# VCC_3.3V_IN VGA_VSYNC VGA_HSYNC VGA_I2C_CK GBE0_MDI0_P GBE0_MDI0_N GBE1_MDI0_P GBE1_MDI0_N SYSRST# J16_SIO2_N COM Express Front Panel for Ruggedized/Military Packaging PMC Site 1 Rear I/O Differential Pair "J14_RIO16+" XMC Site 1 Rear I/O Differential Pair "J16_SIO12+" XMC Site 1 Rear I/O Differential Pair "J16_SIO12-" PMC Site 1 Rear I/O Differential Pair "J14_RIO0-" PMC Site 1 Rear I/O Differential Pair "J14_RIO0+" XMC Site 1 Rear I/O Differential Pair "J16_SIO16+" XMC Site 1 Rear I/O Differential Pair "J16_SIO16-" General Purpose Input 0 General Purpose Output 3 USB1 Differential Pair - "USB1+" USB1 Differential Pair - "USB1-" Ground Ground eDP Differential Pair 1 Negative eDP Differential Pair 1 Positive Ground Ground Digital Display Interface 2 - Output Differential Pair 0 Negative Digital Display Interface 2 - Output Differential Pair 0 Positive Ground Ground Digital Display Interface 3 - AUX Function Select Digital Display Interface 3 - Hot Plug Detect Off-Module Temp Sensor Input Signal Indicating Over-Temp Condition Digital Display Interface 1 - AUX Function Select Digital Display Interface 1 - Hot Plug Detect Output Signal Indicating Soft Off State Output Signal Indicating Suspend to Disk State Output Signal Indicating Suspend to RAM State LPC Serial DMA Request Signal 1 LPC Serial DMA Request Signal 0 3.3V Input Voltage VGA Output Vertical Sync VGA Output Horizontal Sync Display Data Channel (DDC) Clock Line Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Negative System Reset Signal XMC Site 1 Rear I/O Differential Pair "J16_SIO2-" Acromag, Inc. Tel: 248-295-0310 - 24 - D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 D25 D26 D27 D28 D29 D30 D31 D32 D33 D34 D35 D36 D37 D38 D39 D40 D41 D42 D43 D44 D45 D46 D47 D48 D49 D50 E1 E2 www.acromag.com ACEX-FP-IO-0x User’s Manual J16_SIO2_P J16_SIO3_P J16_SIO3_N J16_DP16_N J16_DP16_P J16_DP19_P J16_DP19_N J16_SIO9_P J16_SIO9_N J16_SIO0_GCLK_P J16_SIO0_GCLK_N J16_SIO13_P J16_SIO13_N J16_SIO15_P J16_SIO15_N J16_SIO17_P J16_SIO17_N GPO_2 USB2_+5V GND EDP_TX0_N EDP_TX0_P GND GND DPC_TX2_N DPC_TX2_P GND GND DPC_CTRL_AUX_N DPC_CTRL_AUX_P GND GND I2C_DAT I2C_CLK GND GND SMB_DATA SMB_CLK SMB_ALERT# LPC_SERIRQ LPC_FRAME# COM Express Front Panel for Ruggedized/Military Packaging XMC Site 1 Rear I/O Differential Pair "J16_SIO2+" XMC Site 1 Rear I/O Differential Pair "J16_SIO3+" XMC Site 1 Rear I/O Differential Pair "J16_SIO3-" XMC Site 1 Rear I/O Differential Pair "J16_DP16-" XMC Site 1 Rear I/O Differential Pair "J16_DP16+" XMC Site 1 Rear I/O Differential Pair "J16_DP19+" XMC Site 1 Rear I/O Differential Pair "J16_DP19-" XMC Site 1 Rear I/O Differential Pair "J16_SIO9+" XMC Site 1 Rear I/O Differential Pair "J16_SIO9-" XMC Site 1 Rear I/O Differential Pair "J16_SIO0+" XMC Site 1 Rear I/O Differential Pair "J16_SIO0-" XMC Site 1 Rear I/O Differential Pair "J16_SIO13+" XMC Site 1 Rear I/O Differential Pair "J16_SIO13-" XMC Site 1 Rear I/O Differential Pair "J16_SIO15+" XMC Site 1 Rear I/O Differential Pair "J16_SIO15-" XMC Site 1 Rear I/O Differential Pair "J16_SIO17+" XMC Site 1 Rear I/O Differential Pair "J16_SIO17-" General Purpose Output 2 USB2 Positive 5V from Carrier Ground eDP Differential Pair 0 Negative eDP Differential Pair 0 Positive Ground Ground Differential Pair - "DDI2_PAIR2-" Differential Pair - "DDI2_PAIR2+" Ground Ground Digital Display Interface 2 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 2 - DVI/HDMI/DP AUX Control Positive Ground Ground General Purpose I2C Port Data I/O Line General Purpose I2C Port Clock Output Ground Ground System Management Bus Bidirectional Data Line System Management Bus Bidirectional Clock Line System Management Bus Alert Signal LPC Serial Interrupt Signal LPC Frame Signal - LPC Cycle Start Indicator Acromag, Inc. Tel: 248-295-0310 - 25 - E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 E33 E34 E35 E36 E37 E38 E39 E40 E41 E42 E43 www.acromag.com ACEX-FP-IO-0x User’s Manual VCC_3.3V_IN LPC_AD1 LPC_AD0 GBE0_L1000# GBE1_1V9 GBE0_LINK# GBE1_LINK# J16_DP17_N J16_DP17_P GND GND J16_DP11_N J16_DP11_P GND GND J16_DP07_N J16_DP07_P GND GND J16_SIO10_P J16_SIO10_N GND GND J16_DP02_N J16_DP02_P J16_DP00_N J16_DP00_P USB2_P USB2_N GND GND EDP_TX2_N EDP_TX2_P GND GND DPC_TX1_N DPC_TX1_P GND GND DPD_CTRL_AUX_N DPD_CTRL_AUX_P COM Express Front Panel for Ruggedized/Military Packaging 3.3V Input Voltage LPC Multiplexed Address - Command and Data Bus 1 LPC Multiplexed Address - Command and Data Bus 0 Gigabit Ethernet Controller 0 from Module - 1000 Mb/s Link Indicator External 1.9V Reference Voltage from Carrier for Gigabit Ethernet Controller 1 Gigabit Ethernet Controller 0 from Module - Link Indicator Gigabit Ethernet Controller 1 from Carrier - Link Indicator XMC Site 1 Rear I/O Differential Pair "J16_DP17-" XMC Site 1 Rear I/O Differential Pair "J16_DP17+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP11-" XMC Site 1 Rear I/O Differential Pair "J16_DP11+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP07-" XMC Site 1 Rear I/O Differential Pair "J16_DP07+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO10+" XMC Site 1 Rear I/O Differential Pair "J16_SIO10-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP02-" XMC Site 1 Rear I/O Differential Pair "J16_DP02+" XMC Site 1 Rear I/O Differential Pair "J16_DP00-" XMC Site 1 Rear I/O Differential Pair "J16_DP00+" USB2 Differential Pair - "USB2+" USB2 Differential Pair - "USB2-" Ground Ground eDP Differential Pair 2 Negative eDP Differential Pair 2 Positive Ground Ground Digital Display Interface 2 - Output Differential Pair 1 Negative Digital Display Interface 2 - Output Differential Pair 1 Positive Ground Ground Digital Display Interface 3 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 3 - DVI/HDMI/DP AUX Control Positive Acromag, Inc. Tel: 248-295-0310 - 26 - E44 E45 E46 E47 E48 E49 E50 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 www.acromag.com ACEX-FP-IO-0x User’s Manual GND GND DPB_CTRL_AUX_N DPB_CTRL_AUX_P GND GND PWRBTN# LPC_CLK GND GND LPC_AD3 LPC_AD2 GND GND GBE0_ACT# GBE1_ACT# GND GND J16_SIO5_P J16_SIO5_N GND GND J16_DP08_N J16_DP08_P GND GND J16_DP09_N J16_DP09_P GND GND J16_DP05_N J16_DP05_P GND GND J16_DP01_N J16_DP01_P WAKE1# WAKE0# PCIE0_RX_N PCIE0_RX_P GND COM Express Front Panel for Ruggedized/Military Packaging Ground Ground Digital Display Interface 1 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 1 - DVI/HDMI/DP AUX Control Positive Ground Ground Power Button Input Signal LPC Clock Output - 33MHz Nominal Ground Ground LPC Multiplexed Address - Command and Data Bus 3 LPC Multiplexed Address - Command and Data Bus 2 Ground Ground Gigabit Ethernet Controller 0 from Module - Activity Indicator Gigabit Ethernet Controller 1 from Carrier - Activity Indicator Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO5+" XMC Site 1 Rear I/O Differential Pair "J16_SIO5-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP08-" XMC Site 1 Rear I/O Differential Pair "J16_DP08+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP09-" XMC Site 1 Rear I/O Differential Pair "J16_DP09+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP05-" XMC Site 1 Rear I/O Differential Pair "J16_DP05+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP01-" XMC Site 1 Rear I/O Differential Pair "J16_DP01+" General Purpose Wake Signal PCI Express Wake Signal PCI Express Lane 0 Receive Differential Pair Negative PCI Express Lane 0 Receive Differential Pair Positive Ground Acromag, Inc. Tel: 248-295-0310 - 27 - F35 F36 F37 F38 F39 F40 F41 F42 F43 F44 F45 F46 F47 F48 F49 F50 G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 G19 G20 G21 G22 G23 G24 G25 www.acromag.com ACEX-FP-IO-0x User’s Manual GND PCIE2_RX_N PCIE2_RX_P GND GND DPD_TX3_N DPD_TX3_P GND GND DPB_TX3_N DPB_TX3_P GND GND SATA1_RX_N SATA1_RX_P GND GND USB3_SSRX_P USB3_SSRX_N GND GND USB1_SSRX_P USB1_SSRX_N GND GND J16_DP15_N J16_DP15_P GND GND J16_DP13_N J16_DP13_P GND GND J16_SIO11_P J16_SIO11_N GND GND J16_DP04_N J16_DP04_P GND GND COM Express Front Panel for Ruggedized/Military Packaging Ground PCI Express Lane 2 Receive Differential Pair Negative PCI Express Lane 2 Receive Differential Pair Positive Ground Ground Digital Display Interface 3 - Output Differential Pair 3 Negative Digital Display Interface 3 - Output Differential Pair 3 Positive Ground Ground Digital Display Interface 1 - Output Differential Pair 3 Negative Digital Display Interface 1 - Output Differential Pair 3 Positive Ground Ground SATA1 Receive Differential Pair Negative SATA1 Receive Differential Pair Positive Ground Ground USB3 USB 3.0 SuperSpeed Receive Positive USB3 USB 3.0 SuperSpeed Receive Negative Ground Ground USB1 USB 3.0 SuperSpeed Receive Positive USB1 USB 3.0 SuperSpeed Receive Negative Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP15-" XMC Site 1 Rear I/O Differential Pair "J16_DP15+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP13-" XMC Site 1 Rear I/O Differential Pair "J16_DP13+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO11+" XMC Site 1 Rear I/O Differential Pair "J16_SIO11-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP04-" XMC Site 1 Rear I/O Differential Pair "J16_DP04+" Ground Ground Acromag, Inc. Tel: 248-295-0310 - 28 - G26 G27 G28 G29 G30 G31 G32 G33 G34 G35 G36 G37 G38 G39 G40 G41 G42 G43 G44 G45 G46 G47 G48 G49 G50 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 www.acromag.com ACEX-FP-IO-0x User’s Manual J16_SIO6_N J16_SIO6_P GND GND EDP_AUX_N EDP_AUX_P GND GND PCIE0_TX_N PCIE0_TX_P GND GND PCIE2_TX_N PCIE2_TX_P GND GND DPD_TX0_N DPD_TX0_P GND GND DPB_TX0_N DPB_TX0_P GND GND SATA1_TX_N SATA1_TX_P GND GND USB3_SSTX_P USB3_SSTX_N GND GND USB1_SSTX_P USB1_SSTX_N GND GND J16_SIO7_P J16_SIO7_N GND GND J16_SIO4_P COM Express Front Panel for Ruggedized/Military Packaging XMC Site 1 Rear I/O Differential Pair "J16_SIO6-" XMC Site 1 Rear I/O Differential Pair "J16_SIO6+" Ground Ground eDP AUX Signal Negative eDP AUX Signal Positive Ground Ground PCI Express Lane 0 Transmit Differential Pair Negative PCI Express Lane 0 Transmit Differential Pair Positive Ground Ground PCI Express Lane 2 Transmit Differential Pair Negative PCI Express Lane 2 Transmit Differential Pair Positive Ground Ground Digital Display Interface 3 - Output Differential Pair 0 Negative Digital Display Interface 3 - Output Differential Pair 0 Positive Ground Ground Digital Display Interface 1 - Output Differential Pair 0 Negative Digital Display Interface 1 - Output Differential Pair 0 Positive Ground Ground SATA1 Transmit Differential Pair Negative SATA1 Transmit Differential Pair Positive Ground Ground USB3 USB 3.0 SuperSpeed Transmit Positive USB3 USB 3.0 SuperSpeed Transmit Negative Ground Ground USB1 USB 3.0 SuperSpeed Transmit Positive USB1 USB 3.0 SuperSpeed Transmit Negative Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO7+" XMC Site 1 Rear I/O Differential Pair "J16_SIO7-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO4+" Acromag, Inc. Tel: 248-295-0310 - 29 - H17 H18 H19 H20 H21 H22 H23 H24 H25 H26 H27 H28 H29 H30 H31 H32 H33 H34 H35 H36 H37 H38 H39 H40 H41 H42 H43 H44 H45 H46 H47 H48 H49 H50 J1 J2 J3 J4 J5 J6 J7 www.acromag.com ACEX-FP-IO-0x User’s Manual J16_SIO4_N GND GND J16_DP06_N J16_DP06_P GND GND J16_DP03_N J16_DP03_P GND GND J16_DP12_N J16_DP12_P GND GND PCIE1_RX_N PCIE1_RX_P GND GND PCIE3_RX_N PCIE3_RX_P GND GND DPD_TX2_N DPD_TX2_P GND GND DPB_TX2_N DPB_TX2_P GND GND SATA0_RX_N SATA0_RX_P GND GND USB2_SSRX_P USB2_SSRX_N GND GND USB0_SSRX_P USB0_SSRX_N COM Express Front Panel for Ruggedized/Military Packaging XMC Site 1 Rear I/O Differential Pair "J16_SIO4-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP06-" XMC Site 1 Rear I/O Differential Pair "J16_DP06+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP03-" XMC Site 1 Rear I/O Differential Pair "J16_DP03+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP12-" XMC Site 1 Rear I/O Differential Pair "J16_DP12+" Ground Ground PCI Express Lane 1 Receive Differential Pair Negative PCI Express Lane 1 Receive Differential Pair Positive Ground Ground PCI Express Lane 3 Receive Differential Pair Negative PCI Express Lane 3 Receive Differential Pair Positive Ground Ground Digital Display Interface 3 - Output Differential Pair 2 Negative Digital Display Interface 3 - Output Differential Pair 2 Positive Ground Ground Digital Display Interface 1 - Output Differential Pair 2 Negative Digital Display Interface 1 - Output Differential Pair 2 Positive Ground Ground SATA0 Receive Differential Pair Negative SATA0 Receive Differential Pair Positive Ground Ground USB2 USB 3.0 SuperSpeed Receive Positive USB2 USB 3.0 SuperSpeed Receive Negative Ground Ground USB0 USB 3.0 SuperSpeed Receive Positive USB0 USB 3.0 SuperSpeed Receive Negative Acromag, Inc. Tel: 248-295-0310 - 30 - J8 J9 J10 J11 J12 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J24 J25 J26 J27 J28 J29 J30 J31 J32 J33 J35 J35 J36 J37 J38 J39 J40 J41 J42 J43 J44 J45 J46 J47 J48 www.acromag.com ACEX-FP-IO-0x User’s Manual GND GND J16_DP18_N J16_DP18_P GND GND J16_DP14_N J16_DP14_P GND GND J16_DP10_N J16_DP10_P GND GND J16_SIO14_P J16_SIO14_N GND GND J16_SIO18_GCLK_P J16_SIO18_GCLK_N GND GND CLK_PEG_N CLK_PEG_P GND GND PCIE1_TX_P PCIE1_TX_N GND GND PCIE3_TX_N PCIE3_TX_P GND GND DPD_TX1_N DPD_TX1_P GND GND DPB_TX1_N DPB_TX1_P GND COM Express Front Panel for Ruggedized/Military Packaging Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP18-" XMC Site 1 Rear I/O Differential Pair "J16_DP18+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP14-" XMC Site 1 Rear I/O Differential Pair "J16_DP14+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_DP10-" XMC Site 1 Rear I/O Differential Pair "J16_DP10+" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO14+" XMC Site 1 Rear I/O Differential Pair "J16_SIO14-" Ground Ground XMC Site 1 Rear I/O Differential Pair "J16_SIO18+" XMC Site 1 Rear I/O Differential Pair "J16_SIO18-" Ground Ground PCIe/PEG Reference Clock Output Negative PCIe/PEG Reference Clock Output Positive Ground Ground PCI Express Lane 1 Transmit Differential Pair Positive PCI Express Lane 1 Transmit Differential Pair Negative Ground Ground PCI Express Lane 3 Transmit Differential Pair Negative PCI Express Lane 3 Transmit Differential Pair Positive Ground Ground Digital Display Interface 3 - Output Differential Pair 1 Negative Digital Display Interface 3 - Output Differential Pair 1 Positive Ground Ground Digital Display Interface 1 - Output Differential Pair 1 Negative Digital Display Interface 1 - Output Differential Pair 1 Positive Ground Acromag, Inc. Tel: 248-295-0310 - 31 - J49 J50 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 K15 K16 K17 K18 K19 K20 K21 K22 K23 K24 K25 K26 K27 K28 K29 K30 K31 K32 K33 K34 K35 K36 K37 K38 K39 www.acromag.com ACEX-FP-IO-0x User’s Manual GND SATA0_TX_N SATA0_TX_P GND GND USB2_SSTX_P USB2_SSTX_N GND GND USB0_SSTX_P USB0_SSTX_N COM Express Front Panel for Ruggedized/Military Packaging Ground SATA0 Transmit Differential Pair Negative SATA0 Transmit Differential Pair Positive Ground Ground USB2 USB 3.0 SuperSpeed Transmit Positive USB2 USB 3.0 SuperSpeed Transmit Negative Ground Ground USB0 USB 3.0 SuperSpeed Transmit Positive USB0 USB 3.0 SuperSpeed Transmit Negative Acromag, Inc. Tel: 248-295-0310 - 32 - K40 K41 K42 K43 K44 K45 K46 K47 K48 K49 K50 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J3 – Keyed-A (130-Pin size #23 38999 Connector) PMC/XMC rear I/O from PMC/XMC Site 1 on the carrier (ACEX-46xx) Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Signal Name J14_RIO0_P J14_RIO0_N J14_RIO1_P J14_RIO1_N J14_RIO2_P J14_RIO2_N J14_RIO3_P J14_RIO3_N GND J14_RIO4_P J14_RIO4_N GND J14_RIO5_P J14_RIO5_N GND J14_RIO6_P J14_RIO6_N J14_RIO7_P J14_RIO7_N J14_RIO8_P J14_RIO8_N J14_RIO9_P J14_RIO9_N J14_RIO10_P J14_RIO10_N GND J14_RIO11_P J14_RIO11_N J14_RIO12_P J14_RIO12_N No Connect J14_RIO13_P J14_RIO13_N Pin 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 Acromag, Inc. Tel: 248-295-0310 Signal Name J14_RIO14_P J14_RIO14_N GND J14_RIO15_P J14_RIO15_N GND GND J14_RIO16_P J14_RIO16_N J14_RIO17_P J14_RIO17_N GND GND J14_RIO18_P J14_RIO18_N GND J14_RIO19_P J14_RIO19_N J14_RIO20_P J14_RIO20_N GND J14_RIO21_P J14_RIO21_N J14_RIO22_P J14_RIO22_N GND J14_RIO23_P J14_RIO23_N J14_RIO24_P J14_RIO24_N GND J14_RIO25_P J14_RIO25_N Pin 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Signal Name J14_RIO26_P J14_RIO26_N GND J14_RIO27_P J14_RIO27_N J14_RIO28_P J14_RIO28_N GND J14_RIO29_P J14_RIO29_N GND J14_RIO30_P J14_RIO30_N GND J14_RIO31_P J14_RIO31_N GND J16_SIO0_GCLK_P J16_SIO0_GCLK_N J16_SIO1_P J16_SIO1_N J16_SIO2_P J16_SIO2_N J16_SIO3_P J16_SIO3_N J16_SIO4_P J16_SIO4_N GND J16_SIO5_P J16_SIO5_N GND J16_SIO6_P J16_SIO6_N - 33 - Pin 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 Signal Name GND J16_SIO7_P J16_SIO7_N J16_SIO8_P J16_SIO8_N GND J16_SIO9_P J16_SIO9_N J16_SIO10_P J16_SIO10_N No Connect J16_SIO11_P J16_SIO11_N GND J16_SIO12_P J16_SIO12_N GND J16_SIO13_P J16_SIO13_N GND J16_SIO14_P J16_SIO14_N GND J16_SIO15_P J16_SIO15_N J16_SIO16_P J16_SIO16_N J16_SIO17_P J16_SIO17_N J16_SIO18_GCLK_P J16_SIO18_GCLK_N www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J4 – Keyed-B (130-Pin size #23 38999 Connector) Standard Peripheral I/O Signals Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Signal Name DPB_DDC_CLOCK DPB_DDC_DATA USB0_N USB0_P DPC_DDC_CLOCK DPC_DDC_DATA DPB_TMDS_D1_SHIELD DPB_TMDS_D0_P DPB_TMDS_D0_N USB0_+5V USB0_GND USB1_GND DPC_TMDS_D0_P DPC_TMDS_D0_N DPC_TMDS_D0_SHIELD DPB_TMDS_D1_P DPB_TMDS_D1_N DPB_TMDS_D0_SHIELD GND GND USB1_N USB1_P DPC_TMDS_D1_SHIELD DPC_TMDS_D1_P DPC_TMDS_D1_N DPB_TMDS_D2_P DPB_TMDS_D2_N DPB_TMDS_CLOCK_SHIELD DPB_TMDS_PWR USB2_N USB2_P USB1_+5V DPC_TMDS_PWR Acromag, Inc. Tel: 248-295-0310 Pin 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 Signal Name DPC_TMDS_CLOCK_SHIELD DPC_TMDS_D2_P DPC_TMDS_D2_N DPB_HPD DPB_TMDS_D2_SHIELD DPB_TMDS_CLK_P DPB_TMDS_CLK_N GND USB2_GND USB2_+5V GND DPC_TMDS_CLK_P DPC_TMDS_CLK_N DPC_TMDS_D2_SHIELD DPC_HPD No Connect No Connect No Connect No Connect No Connect No Connect No Connect No Connect GND GND +12V (SATA) LAN0 DI0 P LAN0 DI1 P LAN0 DI2 P LAN0 DI3 P LAN1 DI0 P LAN1 DI1 P LAN1 DI2 P - 34 - Pin 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Signal Name LAN1 DI3 P GND GND +12V (SATA) +5V (SATA) LAN0 DI0 N LAN0 DI1 N LAN0 DI2 N LAN0 DI3 N LAN1 DI0 N LAN1 DI1 N LAN1 DI2 N LAN1 DI3 N UART_RX1_P GND +5V (SATA) GND VGA GND GND SATA0_TX_P SATA0_TX_N GND GND GND UART_TX1_P UART_RX1_N +5V (SATA) +3.3V (SATA) VGA BLUE VGA GND SATA0_RX_N SATA0_RX_P GND Pin 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 Signal Name WDTO GND GND UART_TX1_N GND +3.3V (SATA) VGA RED VGA GND GND GND GND UART_RX0_P LINE IN R AUDIO GND LINE OUT R +3.3V (SATA) VGA GREEN VGA PWR (1.5AHSYNC –FUSED) VGA VGA VSYNC UART_TX0_P UART_RX0_N LINE IN L LINE OUT L AUDIO GND VGA SDATA VGA SCLOCK GND UART_TX0_N GND No Connect www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J5 – Keyed-C (130-Pin size #23 38999 Connector) PMC/XMC rear I/O from PMC/XMC Site 2 on the carrier (ACEX-46xx) Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Signal Name J24_RIO0_P J24_RIO0_N J24_RIO1_P J24_RIO1_N J24_RIO2_P J24_RIO2_N J24_RIO3_P J24_RIO3_N GND J24_RIO4_P J24_RIO4_N GND J24_RIO5_P J24_RIO5_N GND J24_RIO6_P J24_RIO6_N J24_RIO7_P J24_RIO7_N J24_RIO8_P J24_RIO8_N J24_RIO9_P J24_RIO9_N J24_RIO10_P J24_RIO10_N GND J24_RIO11_P J24_RIO11_N J24_RIO12_P J24_RIO12_N No connect J24_RIO13_P J24_RIO13_N Pin 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 Acromag, Inc. Tel: 248-295-0310 Signal Name J24_RIO14_P J24_RIO14_N GND J24_RIO15_P J24_RIO15_N GND GND J24_RIO16_P J24_RIO16_N J24_RIO17_P J24_RIO17_N GND GND J24_RIO18_P J24_RIO18_N GND J24_RIO19_P J24_RIO19_N J24_RIO20_P J24_RIO20_N GND J24_RIO21_P J24_RIO21_N J24_RIO22_P J24_RIO22_N GND J24_RIO23_P J24_RIO23_N J24_RIO24_P J24_RIO24_N GND J24_RIO25_P J24_RIO25_N Pin 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Signal Name J24_RIO26_P J24_RIO26_N GND J24_RIO27_P J24_RIO27_N J24_RIO28_P J24_RIO28_N GND J24_RIO29_P J24_RIO29_N GND J24_RIO30_P J24_RIO30_N GND J24_RIO31_P J24_RIO31_N GND J26_SIO0_GCLK_P J26_SIO0_GCLK_ N J26_SIO1_P J26_SIO1_N J26_SIO2_P J26_SIO2_N J26_SIO3_P J26_SIO3_N J26_SIO4_P J26_SIO4_N GND J26_SIO5_P J26_SIO5_N GND J26_SIO6_P J26_SIO6_N - 35 - Pin 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 Signal Name GND J26_SIO7_P J26_SIO7_N J26_SIO8_P J26_SIO8_N GND J26_SIO9_P J26_SIO9_N J26_SIO10_P J26_SIO10_N No connect J26_SIO11_P J26_SIO11_N GND J26_SIO12_P J26_SIO12_N GND J26_SIO13_P J26_SIO13_N GND J26_SIO14_P J26_SIO14_N GND J26_SIO15_P J26_SIO15_N J26_SIO16_P J26_SIO16_N J26_SIO17_P J26_SIO17_N J26_SIO18_GCLK_P J26_SIO18_GCLK_N www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J6 – Keyed-A (6-Pin size #12 38999 Connectors) Input power connector Pin 1 2 3 4 5 6 Signal Name PWR_BTN Reserved (DO NOT USE) INPUT_PWR INPUT_GND Reserved (DO NOT USE) GND J7 (160-Pin SEARAY Mezzanine Connector) Signals between Site 1 mezzanine board to 38999 connector, J3. A B C D E F G H 1 J14_RIO0_P J14_RIO2_N 14_RIO7_N J14_RIO5_N J14_RIO10_N J14_RIO12_P J14_RIO14_N J14_RIO18_N 2 J14_RIO0_N J14_RIO2_P J14_RIO7_P J14_RIO5_P J14_RIO10_P J14_RIO12_N J14_RIO14_P J14_RIO18_P 3 GND GND GND GND GND GND GND GND 4 J14_RIO3_P J14_RIO4_P J14_RIO8_P J14_RIO1_P J14_RIO11_P J14_RIO22_N J14_RIO31_N J16_SIO18_GCLK_P 5 J14_RIO3_N J14_RIO4_N J14_RIO8_N J14_RIO1_N J14_RIO11_N J14_RIO22_P J14_RIO31_P J16_SIO18_GCLK_N 6 GND GND GND GND GND GND GND GND 7 J14_RIO6_P J14_RIO13_P J14_RIO16_P J14_RIO9_P J14_RIO21_N J16_SIO4_N J16_SIO12_N NC 8 J14_RIO6_N J14_RIO13_N J14_RIO16_N J14_RIO9_N J14_RIO21_P J16_SIO4_P J16_SIO12_P NC 9 GND GND GND GND GND GND GND NC 10 J14_RIO15_P J14_RIO19_P J14_RIO20_P J14_RIO17_P J14_RIO24_N J14_RIO30_P J16_SIO13_N NC 11 J14_RIO15_N J14_RIO19_N J14_RIO20_N J14_RIO17_N J14_RIO24_P J14_RIO30_N J16_SIO13_P NC 12 GND GND GND GND GND GND GND NC 13 J14_RIO23_P J14_RIO29_P J16_SIO11_N J14_RIO25_P J14_RIO26_P J16_SIO0_GCLK_P J16_SIO15_N NC 14 J14_RIO23_N J14_RIO29_N J16_SIO11_P J14_RIO25_N J14_RIO26_N J16_SIO0_GCLK_N J16_SIO15_P NC 15 GND GND GND GND GND GND GND NC 16 J14_RIO28_P J16_SIO3_N J16_SIO10_P J16_SIO1_P J16_SIO7_N J16_SIO8_N J16_SIO14_N NC 17 J14_RIO28_N J16_SIO3_P J16_SIO10_N J16_SIO1_N J16_SIO7_P J16_SIO8_P J16_SIO14_P NC 18 GND GND GND GND GND GND GND NC 19 J16_SIO5_P J16_SIO6_P J16_SIO17_P J14_RIO27_P J16_SIO2_P J16_SIO9_P J16_SIO16_P NC 20 J16_SIO5_N J16_SIO6_N J16_SIO17_N J14_RIO27_N J16_SIO2_N J16_SIO9_N J16_SIO16_N NC Acromag, Inc. Tel: 248-295-0310 - 36 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J8 (160-Pin SEARAY Mezzanine Connector) Signals between system and Site 1 mezzanine board. A B C D E F G H 1 3.3V 3.3V 3.3V J14_RIO15_N J14_RIO19_P J14_RIO18_N J16_SIO7_P J14_RIO23_P 2 5V 5V 5V J14_RIO15_P J14_RIO19_N J14_RIO18_P J16_SIO7_N J14_RIO23_N 3 12V 12V GND J14_RIO13_N J14_RIO11_P J14_RIO14_P J16_SIO8_P J14_RIO25_P 4 J16_SIO4_N J16_SIO14_N J14_RIO12_N J14_RIO13_P J14_RIO11_N J14_RIO14_N J16_SIO8_N J14_RIO25_N 5 J16_SIO4_P J16_SIO14_P J14_RIO12_P J16_SIO2_N J14_RIO24_N J14_RIO7_N J16_SIO9_P J14_RIO27_P 6 J14_RIO31_P J14_RIO8_P J16_SIO5_N J16_SIO2_P J14_RIO24_P J14_RIO7_P J16_SIO9_N J14_RIO27_N 7 J14_RIO31_N J14_RIO8_N J16_SIO5_P J14_RIO9_N J16_SIO1_P J14_RIO10_N J16_SIO10_P J14_RIO29_P 8 GND GND GND J14_RIO9_P J16_SIO1_N J14_RIO10_P J16_SIO10_N J14_RIO29_N 9 J16_SIO6_P J14_RIO26_N J16_SIO15_P J16_SIO3_P J14_RIO20_P J14_RIO6_N J16_SIO11_P J14_RIO17_P 10 J16_SIO6_N J14_RIO26_P J16_SIO15_N J16_SIO3_N J14_RIO20_N J14_RIO6_P J16_SIO11_N J14_RIO17_N 11 J14_RIO4_P J14_RIO0_N J14_RIO30_N J14_RIO5_N J14_RIO3_P J14_RIO28_P J16_SIO12_P J14_RIO22_P 12 J14_RIO4_N J14_RIO0_P J14_RIO30_P J14_RIO5_P J14_RIO3_N J14_RIO28_N J16_SIO12_N J14_RIO22_N 13 GND GND GND WAKE0# I2C_DAT GPI_1 GPI_2 GPI_3 14 J16_SIO0_GCLK_P J16_SIO13_N J16_SIO16_N PLT_RST# I2C_CLK GPO_1 GPO_2 GPO_3 15 J16_SIO0_GCLK_N J16_SIO13_P J16_SIO16_P SATA1_TX_P GND GND GND GND 16 J16_SIO18_GCLK_N J14_RIO2_N J14_RIO16_P SATA1_TX_N PCIE0_RX_N PCIE0_TX_N PCIE2_TX_P PCIE3_TX_P 17 J16_SIO18_GCLK_P J14_RIO2_P J14_RIO16_N SATA1_RX_N PCIE0_RX_P PCIE0_TX_P PCIE2_TX_N PCIE3_TX_N 18 GND GND GND SATA1_RX_P GND GND GND GND 19 J16_SIO17_N J14_RIO21_P J14_RIO1_N PCIE1_RX_P PCIE_CLK_PEG_N PCIE1_TX_N PCIE2_RX_P PCIE3_RX_P 20 J16_SIO17_P J14_RIO21_N J14_RIO1_P PCIE1_RX_N PCIE_CLK_PEG_P PCIE1_TX_P PCIE2_RX_N PCIE3_RX_N Acromag, Inc. Tel: 248-295-0310 - 37 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J9 (160-Pin SEARAY Mezzanine Connector) Signals between Site 2 mezzanine board and 38999 connector, J5. A B C D E F G H 1 J24_RIO0_P J24_RIO2_N J24_IO7_N J24_RIO5_N J24_RIO10_N J24_RIO12_P J24_RIO14_N J24_RIO18_N 2 J24_RIO0_N J24_RIO2_P J24_RIO7_P J24_RIO5_P J24_RIO10_P J24_RIO12_N J24_RIO14_P J24_RIO18_P 3 GND GND GND GND GND GND GND GND 4 J24_RIO3_P J24_RIO4_P J24_RIO8_P J24_RIO1_P J24_RIO11_P J24_RIO22_N J24_RIO31_N J26_SIO18_GCLK_P 5 J24_RIO3_N J24_RIO4_N J24_RIO8_N J24_RIO1_N J24_RIO11_N J24_RIO22_P J24_RIO31_P J26_SIO18_GCLK_N 6 GND GND GND GND GND GND GND GND 7 J24_RIO6_P J24_RIO13_P J24_RIO16_P J24_RIO9_P J24_RIO21_N J26_SIO4_N J26_SIO12_N NC 8 J24_RIO6_N J24_RIO13_N J24_RIO16_N J24_RIO9_N J24_RIO21_P J26_SIO4_P J26_SIO12_P NC 9 GND GND GND GND GND GND GND NC 10 J24_RIO15_P J24_RIO19_P J24_RIO20_P J24_RIO17_P J24_RIO24_N J24_RIO30_P J26_SIO13_N NC 11 J24_RIO15_N J24_RIO19_N J24_RIO20_N J24_RIO17_N J24_RIO24_P J24_RIO30_N J26_SIO13_P NC 12 GND GND GND GND GND GND GND NC 13 J24_RIO23_P J24_RIO29_P J26_SIO11_N J24_RIO25_P J24_RIO26_P J26_SIO0_GCLK_P J26_SIO15_N NC 14 J24_RIO23_N J24_RIO29_N J26_SIO11_P J24_RIO25_N J24_RIO26_N J26_SIO0_GCLK_N J26_SIO15_P NC 15 GND GND GND GND GND GND GND NC 16 J24_RIO28_P J26_SIO3_N J26_SIO10_P J26_SIO1_P J26_SIO7_N J26_SIO8_N J26_SIO14_N NC 17 J24_RIO28_N J26_SIO3_P J26_SIO10_N J26_SIO1_N J26_SIO7_P J26_SIO8_P J26_SIO14_P NC 18 GND GND GND GND GND GND GND NC 19 J26_SIO5_P J26_SIO6_P J26_SIO17_P J24_RIO27_P J26_SIO2_P J26_SIO9_P J26_SIO16_P NC 20 J26_SIO5_N J26_SIO6_N J26_SIO17_N J24_RIO27_N J26_SIO2_N J26_SIO9_N J26_SIO16_N NC Acromag, Inc. Tel: 248-295-0310 - 38 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging J10 (160-Pin SEARAY Mezzanine Connector) Signals between system and Site 2 mezzanine board. A B C D E F G H 1 3.3V 3.3V 3.3V J24_RIO15_N J24_RIO19_P J24_RIO18_N J26_SIO7_P J24_RIO23_P 2 5V 5V 5V J24_RIO15_P J24_RIO19_N J24_RIO18_P J26_SIO7_N J24_RIO23_N 3 12V 12V GND J24_RIO13_N J24_RIO11_P J24_RIO14_P J26_SIO8_P J24_RIO25_P 4 J26_SIO4_N J26_SIO14_N J24_RIO12_N J24_RIO13_P J24_RIO11_N J24_RIO14_N J26_SIO8_N J24_RIO25_N 5 J26_SIO4_P J26_SIO14_P J24_RIO12_P J26_SIO2_N J24_RIO24_N J24_RIO7_N J26_SIO9_P J24_RIO27_P 6 J24_RIO31_P J24_RIO8_P J26_SIO5_N J26_SIO2_P J24_RIO24_P J24_RIO7_P J26_SIO9_N J24_RIO27_N 7 J24_RIO31_N J24_RIO8_N J26_SIO5_P J24_RIO9_N J26_SIO1_P J24_RIO10_N J26_SIO10_P J24_RIO29_P 8 GND GND GND J24_RIO9_P J26_SIO1_N J24_RIO10_P J26_SIO10_N J24_RIO29_N 9 J26_SIO6_P J24_RIO26_N J26_SIO15_P J26_SIO3_P J24_RIO20_P J24_RIO6_N J26_SIO11_P J24_RIO17_P 10 J26_SIO6_N J24_RIO26_P J26_SIO15_N J26_SIO3_N J24_RIO20_N J24_RIO6_P J26_SIO11_N J24_RIO17_N 11 J24_RIO4_P J24_RIO0_N J24_RIO30_N J24_RIO5_N J24_RIO3_P J24_RIO28_P J26_SIO12_P J24_RIO22_P 12 J24_RIO4_N J24_RIO0_P J24_RIO30_P J24_RIO5_P J24_RIO3_N J24_RIO28_N J26_SIO12_N J24_RIO22_N 13 GND GND GND J26_DP00_N J26_DP04_N J26_DP08_N J26_DP12_N J26_DP16_N 14 J26_SIO0_GCLK_P J26_SIO13_N J26_SIO16_N J26_DP00_P J26_DP04_P J26_DP08_P J26_DP12_P J26_DP16_P 15 J26_SIO0_GCLK_N J26_SIO13_P J26_SIO16_P J26_DP01_N J26_DP05_N J26_DP09_N J26_DP13_N J26_DP17_N 16 J26_SIO18_GCLK_N J24_RIO2_N J24_RIO16_P J26_DP01_P J26_DP05_P J26_DP09_P J26_DP13_P J26_DP17_P 17 J26_SIO18_GCLK_P J24_RIO2_P J24_RIO16_N J26_DP02_N J26_DP06_N J26_DP10_N J26_DP14_N J26_DP18_N 18 GND GND GND J26_DP02_P J26_DP06_P J26_DP10_P J26_DP14_P J26_DP18_P 19 J26_SIO17_N J24_RIO21_P J24_RIO1_N J26_DP03_N J26_DP07_N J26_DP11_N J26_DP15_N J26_DP19_N 20 J26_SIO17_P J24_RIO21_N J24_RIO1_P J26_DP03_P J26_DP07_P J26_DP11_P J26_DP15_P J26_DP19_P Acromag, Inc. Tel: 248-295-0310 - 39 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Handling Modules should be handled in ESD-safe work areas in order to prevent damage to sensitive components from electrostatic discharges. These areas must be designed and maintained to prevent ESD damage. ESD Safe Work Area Guidelines 1. Module should be handled at properly designated work areas only. 2. Designated ESD safe work areas must be checked periodically to ensure their continued safety from ESD. The areas should be monitored for the following: a. Proper grounding methods. b. Static dissipation of work surfaces. c. Static dissipation of floor surfaces. d. Operation of ion blowers and ion air guns. 3. Designated work areas must be kept free of static generating materials such as styrofoam, vinyl, plastic, fabrics or any other static generating materials. 4. Work areas must be kept clean and neat in order to prevent contamination of the work area. 5. Modules should be handled by the edges. Avoid touching the component leads. NOTE: When not installed in a system, modules must be enclosed in shielded bags or boxes. There are three types of ESD protective enclosure materials this module was shipped in an approved ESD bag. 6. Whenever handling the module the operator must be properly grounded by one of the following: a. Wearing a wrist strap connected to earth ground. b. Wearing heel grounders and have both feet on a static dissipative floor surface. 7. Stacking of modules should be avoided to prevent physical damage. Acromag, Inc. Tel: 248-295-0310 - 40 - www.acromag.com ACEX-FP-IO-0x User’s Manual 6.0 COM Express Front Panel for Ruggedized/Military Packaging Service and Repair Surface-Mounted Technology (SMT) boards are generally difficult to repair. It is highly recommended that a non-functioning board be returned to Acromag for repair. The board can be easily damaged unless special SMT repair and service tools are used. Further, Acromag has automated test equipment that thoroughly checks the performance of each board. When a board is first produced and when any repair is made, it is tested before shipment. Service and Repair Assistance Please refer to Acromag's Service Policy Bulletin or contact Acromag for complete details on how to obtain parts and repair. Preliminary Service Procedure CAUTION: POWER MUST BE TURNED OFF BEFORE REMOVING OR INSERTING BOARDS Before beginning repair, be sure that all of the procedures in the "Preparation for Use" section have been followed. Also, refer to the documentation of your board to verify that it is correctly configured. Replacement of the board with one that is known to work correctly is a good technique to isolate a faulty board. Where to Get Help If you continue to have problems, your next step should be to visit the Acromag worldwide web site at http://www.acromag.com. Our web site contains the most up-to-date product and software information. Acromag’s application engineers can also be contacted directly for technical assistance via email, telephone, or FAX through the contact information listed at the bottom of this page. When needed, complete repair services are also available. Acromag, Inc. Tel: 248-295-0310 - 41 - www.acromag.com ACEX-FP-IO-0x User’s Manual 7.0 COM Express Front Panel for Ruggedized/Military Packaging Specifications Physical ACEX-FP-IO-01: Height Width Board Thickness 68.58 mm (2.700 in) 125 mm (4.921 in) 2.36 mm (0.093 in) Unit Weight: 6.13oz (0.1738Kg) ACEX-FP-IO-02: Height Width Board Thickness 68.58 mm (2.700 in) 200 mm (7.874 in) 2.36 mm (0.093 in) Unit Weight: 9.37oz (0.2655Kg) Power Requirements Note: The maximum current supplied to the Carrier/Module cannot exceed 15 Amps. Minimum Input Voltage +10V DC Maximum Input Voltage +36V DC Environmental Operating Temperature Operating Temperature Model ACEX-FP-IO-01 ACEX-FP-IO-02 -40C to 85C Relative Humidity: 5-95% Non-Condensing. Storage Temperature: -55C to 100C. Acromag, Inc. Tel: 248-295-0310 - 42 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Appendix The table below is the 500-Pin SEARAY pin-out as it relates to the technology type. Note: Not all signals listed below are used in the ACEX-FP-IO-0x design. 500 - Pin SEARAY Connector pin-out by Type DDI 1 Signal Name DPB_TX0_N DPB_TX0_P DPB_TX1_N DPB_TX1_P DPB_TX2_N DPB_TX2_P DPB_TX3_N DPB_TX3_P DPB_AUX_SEL DPB_CTRL_AUX_N DPB_CTRL_AUX_P DPB_HPD Description Digital Display Interface 1 - Output Differential Pair 0 Negative Digital Display Interface 1 - Output Differential Pair 0 Positive Digital Display Interface 1 - Output Differential Pair 1 Negative Digital Display Interface 1 - Output Differential Pair 1 Positive Digital Display Interface 1 - Output Differential Pair 2 Negative Digital Display Interface 1 - Output Differential Pair 2 Positive Digital Display Interface 1 - Output Differential Pair 3 Negative Digital Display Interface 1 - Output Differential Pair 3 Positive Digital Display Interface 1 - AUX Function Select Digital Display Interface 1 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 1 - DVI/HDMI/DP AUX Control Positive Digital Display Interface 1 - Hot Plug Detect SEARAY Pin H37 H38 K37 K38 J35 J36 G35 G36 D36 F37 F38 D37 DDI 2 Signal Name DPC_TX0_N DPC_TX0_P DPC_TX1_N DPC_TX1_P DPC_TX2_N DPC_TX2_P DPC_TX3_N DPC_TX3_P DPC_AUX_SEL DPC_CTRL_AUX_N DPC_CTRL_AUX_P DPC_HPD Description Digital Display Interface 2 - Output Differential Pair 0 Negative Digital Display Interface 2 - Output Differential Pair 0 Positive Digital Display Interface 2 - Output Differential Pair 1 Negative Digital Display Interface 2 - Output Differential Pair 1 Positive Differential Pair - "DDI2_PAIR2-" Differential Pair - "DDI2_PAIR2+" Digital Display Interface 2 - Output Differential Pair 3 Negative Digital Display Interface 2 - Output Differential Pair 3 Positive Digital Display Interface 2 - AUX Function Select Digital Display Interface 2 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 2 - DVI/HDMI/DP AUX Control Positive Digital Display Interface 2 - Hot Plug Detect Acromag, Inc. Tel: 248-295-0310 - 43 - SEARAY Pin D29 D30 F29 F30 E27 E28 C27 C28 B32 E31 E32 C33 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging DDI 3 Signal Name DPD_TX0_N DPD_TX0_P DPD_TX1_N DPD_TX1_P DPD_TX2_N DPD_TX2_P DPD_TX3_N DPD_TX3_P DPD_AUX_SEL DPD_CTRL_AUX_N DPD_CTRL_AUX_P DPD_HPD Description Digital Display Interface 3 - Output Differential Pair 0 Negative Digital Display Interface 3 - Output Differential Pair 0 Positive Digital Display Interface 3 - Output Differential Pair 1 Negative Digital Display Interface 3 - Output Differential Pair 1 Positive Digital Display Interface 3 - Output Differential Pair 2 Negative Digital Display Interface 3 - Output Differential Pair 2 Positive Digital Display Interface 3 - Output Differential Pair 3 Negative Digital Display Interface 3 - Output Differential Pair 3 Positive Digital Display Interface 3 - AUX Function Select Digital Display Interface 3 - DVI/HDMI/DP AUX Control Negative Digital Display Interface 3 - DVI/HDMI/DP AUX Control Positive Digital Display Interface 3 - Hot Plug Detect SEARAY Pin H33 H34 K33 K34 J31 J32 G31 G32 D33 F33 F34 D34 eDP Signal Name EDP_TX0_N EDP_TX0_P EDP_TX1_N EDP_TX1_P EDP_TX2_N EDP_TX2_P EDP_TX3_N EDP_TX3_P EDP_VDDEN EDP_BKLTEN EDP_BKLTCTL EDP_AUX_P EDP_AUX_N EDP_HPD SEARAY Pin E23 E24 D25 D26 F25 F26 C23 C24 C22 A28 A27 H22 H21 A26 Description eDP Differential Pair 0 Negative eDP Differential Pair 0 Positive eDP Differential Pair 1 Negative eDP Differential Pair 1 Positive eDP Differential Pair 2 Negative eDP Differential Pair 2 Positive eDP Differential Pair 3 Negative eDP Differential Pair 3 Positive eDP Power Enable eDP Backlight Enable eDP Backlight Brightness Control eDP AUX Signal Positive eDP AUX Signal Negative eDP Hot Plug Detect Acromag, Inc. Tel: 248-295-0310 - 44 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging VGA Signal Name VGA_RED VGA_GRN VGA_BLU VGA_HSYNC VGA_VSYNC VGA_I2C_CK VGA_I2C_DAT SEARAY Pin B44 B45 B43 D45 D44 D46 C46 Description Analog Video Output Red Analog Video Output Green Analog Video Output Blue VGA Output Horizontal Sync VGA Output Vertical Sync Display Data Channel (DDC) Clock Line Display Data Channel (DDC) Data Line SATA Signal Name SATA0_RX_N SATA0_RX_P SATA0_TX_N SATA0_TX_P SATA1_RX_N SATA1_RX_P SATA1_TX_N SATA1_TX_P SATA_ACT# Description SATA0 Receive Differential Pair Negative SATA0 Receive Differential Pair Positive SATA0 Transmit Differential Pair Negative SATA0 Transmit Differential Pair Positive SATA1 Receive Differential Pair Negative SATA1 Receive Differential Pair Positive SATA1 Transmit Differential Pair Negative SATA1 Transmit Differential Pair Positive ATA (Parallel and Serial) or SAS Activity Indicator Signal SEARAY Pin J39 J40 K41 K42 G39 G40 H41 H42 C40 USB0 Signal Name USB0_+5V USB0_P USB0_N USB0_SSRX_P USB0_SSRX_N USB0_SSTX_P USB0_SSTX_N Description USB0 Positive 5V from Carrier USB0 Differential Pair - "USB0+" USB0 Differential Pair - "USB0-" USB0 USB 3.0 SuperSpeed Receive Positive USB0 USB 3.0 SuperSpeed Receive Negative USB0 USB 3.0 SuperSpeed Transmit Positive USB0 USB 3.0 SuperSpeed Transmit Negative Acromag, Inc. Tel: 248-295-0310 - 45 - SEARAY Pin A21 B21 B22 J47 J48 K49 K50 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging USB1 Signal Name USB1_+5V USB1_P USB1_N USB1_SSRX_P USB1_SSRX_N USB1_SSTX_P USB1_SSTX_N Description USB1 Positive 5V from Carrier USB1 Differential Pair - "USB1+" USB1 Differential Pair - "USB1-" USB1 USB 3.0 SuperSpeed Receive Positive USB1 USB 3.0 SuperSpeed Receive Negative USB1 USB 3.0 SuperSpeed Transmit Positive USB1 USB 3.0 SuperSpeed Transmit Negative SEARAY Pin C21 D21 D22 G47 G48 H49 H50 USB2 Signal Name USB2_+5V USB2_P USB2_N USB2_SSRX_P USB2_SSRX_N USB2_SSTX_P USB2_SSTX_N Description USB2 Positive 5V from Carrier USB2 Differential Pair - "USB2+" USB2 Differential Pair - "USB2-" USB2 USB 3.0 SuperSpeed Receive Positive USB2 USB 3.0 SuperSpeed Receive Negative USB2 USB 3.0 SuperSpeed Transmit Positive USB2 USB 3.0 SuperSpeed Transmit Negative SEARAY Pin E21 F21 F22 J43 J44 K45 K46 USB3 Signal Name USB3_+5V USB3_P USB3_N USB3_SSRX_P USB3_SSRX_N USB3_SSTX_P USB3_SSTX_N Description USB3 Positive 5V from Carrier USB3 Differential Pair - "USB3+" USB3 Differential Pair - "USB3-" USB3 USB 3.0 SuperSpeed Receive Positive USB3 USB 3.0 SuperSpeed Receive Negative USB3 USB 3.0 SuperSpeed Transmit Positive USB3 USB 3.0 SuperSpeed Transmit Negative SEARAY Pin A25 B25 B26 G43 G44 H45 H46 USB4 Signal Name USB4_+5V USB4_P USB4_N SEARAY Pin A29 B29 B30 Description USB4 Positive 5V from Carrier USB4 Differential Pair - "USB4+" USB4 Differential Pair - "USB4-" Acromag, Inc. Tel: 248-295-0310 - 46 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging USB5 Signal Name USB5_+5V USB5_P USB5_N SEARAY Pin B31 C31 C32 Description USB5 Positive 5V from Carrier USB5 Differential Pair - "USB5+" USB5 Differential Pair - "USB5-" Serial Signal Name UART_TX0_P UART_TX0_N UART_RX0_P UART_RX0_N UART_TX1_P UART_TX1_N UART_RX1_P UART_RX1_N SEARAY Pin B33 B34 B35 B36 B37 B38 B39 B40 Description General Purpose Serial Port 0 from Carrier Transmitter Positive General Purpose Serial Port 0 from Carrier Transmitter Negative General Purpose Serial Port 0 from Carrier Receiver Positive General Purpose Serial Port 0 from Carrier Receiver Negative General Purpose Serial Port 1 from Carrier Transmitter Positive General Purpose Serial Port 1 from Carrier Transmitter Negative General Purpose Serial Port 1 from Carrier Receiver Positive General Purpose Serial Port 1 from Carrier Receiver Negative LAN0 Signal Name GBE0_MDI0_P GBE0_MDI0_N GBE0_MDI1_P GBE0_MDI1_N GBE0_MDI2_P GBE0_MDI2_N GBE0_MDI3_P GBE0_MDI3_N GBE0_ACT# GBE0_LINK# GBE0_L1000# Description Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Negative Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Negative Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Negative Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Positive Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Negative Gigabit Ethernet Controller 0 from Module - Activity Indicator Gigabit Ethernet Controller 0 from Module - Link Indicator Gigabit Ethernet Controller 0 from Module - 1000 Mb/s Link Indicator Acromag, Inc. Tel: 248-295-0310 - 47 - SEARAY Pin D47 D48 C47 C48 B47 B48 A47 A48 F49 E49 E47 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging LAN1 Signal Name GBE1_MDI0_P GBE1_MDI0_N GBE1_MDI1_P GBE1_MDI1_N GBE1_MDI2_P GBE1_MDI2_N GBE1_MDI3_P GBE1_MDI3_N GBE1_ACT# GBE1_LINK# GBE1_1V9 Description Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Negative Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Positive Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Negative Gigabit Ethernet Controller 1 from Carrier - Activity Indicator Gigabit Ethernet Controller 1 from Carrier - Link Indicator External 1.9V Reference Voltage from Carrier for Gigabit Ethernet Controller 1 SEARAY Pin D49 D50 C49 C50 B49 B50 A49 A50 F50 E50 E48 Audio Signal Name LINE-IN_R LINE-IN_L LINE-OUT_R LINE-OUT_L AUDIO_GND Description Right Channel Audio Line In from CODEC on Carrier Left Channel Audio Line In from CODEC on Carrier Right Channel Audio Line Out from CODEC on Carrier Left Channel Audio Line Out from CODEC on Carrier AUDIO_GND connected to Digital GND near CODEC on Carrier Acromag, Inc. Tel: 248-295-0310 - 48 - SEARAY Pin A44 A45 A42 B42 A43 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging PCIE Signal Name PCIE0_RX_N PCIE0_RX_P PCIE0_TX_N PCIE0_TX_P PCIE1_RX_N PCIE1_RX_P PCIE1_TX_P PCIE1_TX_N PCIE2_RX_N PCIE2_RX_P PCIE2_TX_N PCIE2_TX_P PCIE3_RX_N PCIE3_RX_P PCIE3_TX_N PCIE3_TX_P CLK_PEG_N CLK_PEG_P Description PCI Express Lane 0 Receive Differential Pair Negative PCI Express Lane 0 Receive Differential Pair Positive PCI Express Lane 0 Transmit Differential Pair Negative PCI Express Lane 0 Transmit Differential Pair Positive PCI Express Lane 1 Receive Differential Pair Negative PCI Express Lane 1 Receive Differential Pair Positive PCI Express Lane 1 Transmit Differential Pair Positive PCI Express Lane 1 Transmit Differential Pair Negative PCI Express Lane 2 Receive Differential Pair Negative PCI Express Lane 2 Receive Differential Pair Positive PCI Express Lane 2 Transmit Differential Pair Negative PCI Express Lane 2 Transmit Differential Pair Positive PCI Express Lane 3 Receive Differential Pair Negative PCI Express Lane 3 Receive Differential Pair Positive PCI Express Lane 3 Transmit Differential Pair Negative PCI Express Lane 3 Transmit Differential Pair Positive PCIe/PEG Reference Clock Output Negative PCIe/PEG Reference Clock Output Positive Acromag, Inc. Tel: 248-295-0310 - 49 - SEARAY Pin G23 G24 H25 H26 J23 J24 K25 K26 G27 G28 H29 H30 J27 J28 K29 K30 K21 K22 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging PMC Site 1 Signal Name J14_RIO0_N J14_RIO0_P J14_RIO1_N J14_RIO1_P J14_RIO2_N J14_RIO2_P J14_RIO3_N J14_RIO3_P J14_RIO4_N J14_RIO4_P J14_RIO5_N J14_RIO5_P J14_RIO6_N J14_RIO6_P J14_RIO7_N J14_RIO7_P J14_RIO8_N J14_RIO8_P J14_RIO9_N J14_RIO9_P J14_RIO10_N J14_RIO10_P J14_RIO11_N J14_RIO11_P J14_RIO12_N J14_RIO12_P J14_RIO13_N J14_RIO13_P J14_RIO14_N J14_RIO14_P J14_RIO15_N J14_RIO15_P J14_RIO16_N J14_RIO16_P J14_RIO17_N J14_RIO17_P J14_RIO18_N J14_RIO18_P Description PMC Site 1 Rear I/O Differential Pair "J14_RIO0-" PMC Site 1 Rear I/O Differential Pair "J14_RIO0+" PMC Site 1 Rear I/O Differential Pair "J14_RIO1-" PMC Site 1 Rear I/O Differential Pair "J14_RIO1+" PMC Site 1 Rear I/O Differential Pair "J14_RIO2-" PMC Site 1 Rear I/O Differential Pair "J14_RIO2+" PMC Site 1 Rear I/O Differential Pair "J14_RIO3-" PMC Site 1 Rear I/O Differential Pair "J14_RIO3+" PMC Site 1 Rear I/O Differential Pair "J14_RIO4-" PMC Site 1 Rear I/O Differential Pair "J14_RIO4+" PMC Site 1 Rear I/O Differential Pair "J14_RIO5-" PMC Site 1 Rear I/O Differential Pair "J14_RIO5+" PMC Site 1 Rear I/O Differential Pair "J14_RIO6-" PMC Site 1 Rear I/O Differential Pair "J14_RIO6+" PMC Site 1 Rear I/O Differential Pair "J14_RIO7-" PMC Site 1 Rear I/O Differential Pair "J14_RIO7+" PMC Site 1 Rear I/O Differential Pair "J14_RIO8-" PMC Site 1 Rear I/O Differential Pair "J14_RIO8+" PMC Site 1 Rear I/O Differential Pair "J14_RIO9-" PMC Site 1 Rear I/O Differential Pair "J14_RIO9+" PMC Site 1 Rear I/O Differential Pair "J14_RIO10-" PMC Site 1 Rear I/O Differential Pair "J14_RIO10+" PMC Site 1 Rear I/O Differential Pair "J14_RIO11-" PMC Site 1 Rear I/O Differential Pair "J14_RIO11+" PMC Site 1 Rear I/O Differential Pair "J14_RIO12-" PMC Site 1 Rear I/O Differential Pair "J14_RIO12+" PMC Site 1 Rear I/O Differential Pair "J14_RIO13-" PMC Site 1 Rear I/O Differential Pair "J14_RIO13+" PMC Site 1 Rear I/O Differential Pair "J14_RIO14-" PMC Site 1 Rear I/O Differential Pair "J14_RIO14+" PMC Site 1 Rear I/O Differential Pair "J14_RIO15-" PMC Site 1 Rear I/O Differential Pair "J14_RIO15+" PMC Site 1 Rear I/O Differential Pair "J14_RIO16-" PMC Site 1 Rear I/O Differential Pair "J14_RIO16+" PMC Site 1 Rear I/O Differential Pair "J14_RIO17-" PMC Site 1 Rear I/O Differential Pair "J14_RIO17+" PMC Site 1 Rear I/O Differential Pair "J14_RIO18-" PMC Site 1 Rear I/O Differential Pair "J14_RIO18+" Acromag, Inc. Tel: 248-295-0310 - 50 - SEARAY Pin D15 D16 C8 C9 C10 C11 D7 D8 C17 C16 C6 C7 B9 B10 B5 B6 B18 B17 C4 C5 B7 B8 D3 D4 C14 C15 C2 C3 B4 B3 D1 D2 D11 D12 B12 B11 B1 B2 www.acromag.com ACEX-FP-IO-0x User’s Manual J14_RIO19_N J14_RIO19_P J14_RIO20_N J14_RIO20_P J14_RIO21_N J14_RIO21_P J14_RIO22_N J14_RIO22_P J14_RIO23_N J14_RIO23_P J14_RIO24_N J14_RIO24_P J14_RIO25_N J14_RIO25_P J14_RIO26_N J14_RIO26_P J14_RIO27_N J14_RIO27_P J14_RIO28_N J14_RIO28_P J14_RIO29_N J14_RIO29_P J14_RIO30_N J14_RIO30_P J14_RIO31_N J14_RIO31_P COM Express Front Panel for Ruggedized/Military Packaging PMC Site 1 Rear I/O Differential Pair "J14_RIO19-" PMC Site 1 Rear I/O Differential Pair "J14_RIO19+" PMC Site 1 Rear I/O Differential Pair "J14_RIO20-" PMC Site 1 Rear I/O Differential Pair "J14_RIO20+" PMC Site 1 Rear I/O Differential Pair "J14_RIO21-" PMC Site 1 Rear I/O Differential Pair "J14_RIO21+" PMC Site 1 Rear I/O Differential Pair "J14_RIO22-" PMC Site 1 Rear I/O Differential Pair "J14_RIO22+" PMC Site 1 Rear I/O Differential Pair "J14_RIO23-" PMC Site 1 Rear I/O Differential Pair "J14_RIO23+" PMC Site 1 Rear I/O Differential Pair "J14_RIO24-" PMC Site 1 Rear I/O Differential Pair "J14_RIO24+" PMC Site 1 Rear I/O Differential Pair "J14_RIO25-" PMC Site 1 Rear I/O Differential Pair "J14_RIO25+" PMC Site 1 Rear I/O Differential Pair "J14_RIO26-" PMC Site 1 Rear I/O Differential Pair "J14_RIO26+" PMC Site 1 Rear I/O Differential Pair "J14_RIO27-" PMC Site 1 Rear I/O Differential Pair "J14_RIO27+" PMC Site 1 Rear I/O Differential Pair "J14_RIO28-" PMC Site 1 Rear I/O Differential Pair "J14_RIO28+" PMC Site 1 Rear I/O Differential Pair "J14_RIO29-" PMC Site 1 Rear I/O Differential Pair "J14_RIO29+" PMC Site 1 Rear I/O Differential Pair "J14_RIO30-" PMC Site 1 Rear I/O Differential Pair "J14_RIO30+" PMC Site 1 Rear I/O Differential Pair "J14_RIO31-" PMC Site 1 Rear I/O Differential Pair "J14_RIO31+" Acromag, Inc. Tel: 248-295-0310 - 51 - A2 A3 A6 A7 A8 A9 B14 B13 A11 A10 A5 A4 A13 A12 B16 B15 A15 A14 C13 C12 A17 A16 C19 C18 A19 A18 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging XMC Site 1 Signal Name J16_SIO0_GCLK_P J16_SIO0_GCLK_N J16_SIO1_P J16_SIO1_N J16_SIO2_P J16_SIO2_N J16_SIO3_P J16_SIO3_N J16_SIO4_P J16_SIO4_N J16_SIO5_P J16_SIO5_N J16_SIO6_P J16_SIO6_N J16_SIO7_P J16_SIO7_N J16_SIO8_P J16_SIO8_N J16_SIO9_P J16_SIO9_N J16_SIO10_P J16_SIO10_N J16_SIO11_P J16_SIO11_N J16_SIO12_P J16_SIO12_N J16_SIO13_P J16_SIO13_N J16_SIO14_P J16_SIO14_N J16_SIO15_P J16_SIO15_N J16_SIO16_P J16_SIO16_N J16_SIO17_P J16_SIO17_N J16_SIO18_GCLK_P J16_SIO18_GCLK_N Description XMC Site 1 Rear I/O Differential Pair "J16_SIO0+" XMC Site 1 Rear I/O Differential Pair "J16_SIO0-" XMC Site 1 Rear I/O Differential Pair "J16_SIO1+" XMC Site 1 Rear I/O Differential Pair "J16_SIO1-" XMC Site 1 Rear I/O Differential Pair "J16_SIO2+" XMC Site 1 Rear I/O Differential Pair "J16_SIO2-" XMC Site 1 Rear I/O Differential Pair "J16_SIO3+" XMC Site 1 Rear I/O Differential Pair "J16_SIO3-" XMC Site 1 Rear I/O Differential Pair "J16_SIO4+" XMC Site 1 Rear I/O Differential Pair "J16_SIO4-" XMC Site 1 Rear I/O Differential Pair "J16_SIO5+" XMC Site 1 Rear I/O Differential Pair "J16_SIO5-" XMC Site 1 Rear I/O Differential Pair "J16_SIO6+" XMC Site 1 Rear I/O Differential Pair "J16_SIO6-" XMC Site 1 Rear I/O Differential Pair "J16_SIO7+" XMC Site 1 Rear I/O Differential Pair "J16_SIO7-" XMC Site 1 Rear I/O Differential Pair "J16_SIO8+" XMC Site 1 Rear I/O Differential Pair "J16_SIO8-" XMC Site 1 Rear I/O Differential Pair "J16_SIO9+" XMC Site 1 Rear I/O Differential Pair "J16_SIO9-" XMC Site 1 Rear I/O Differential Pair "J16_SIO10+" XMC Site 1 Rear I/O Differential Pair "J16_SIO10-" XMC Site 1 Rear I/O Differential Pair "J16_SIO11+" XMC Site 1 Rear I/O Differential Pair "J16_SIO11-" XMC Site 1 Rear I/O Differential Pair "J16_SIO12+" XMC Site 1 Rear I/O Differential Pair "J16_SIO12-" XMC Site 1 Rear I/O Differential Pair "J16_SIO13+" XMC Site 1 Rear I/O Differential Pair "J16_SIO13-" XMC Site 1 Rear I/O Differential Pair "J16_SIO14+" XMC Site 1 Rear I/O Differential Pair "J16_SIO14-" XMC Site 1 Rear I/O Differential Pair "J16_SIO15+" XMC Site 1 Rear I/O Differential Pair "J16_SIO15-" XMC Site 1 Rear I/O Differential Pair "J16_SIO16+" XMC Site 1 Rear I/O Differential Pair "J16_SIO16-" XMC Site 1 Rear I/O Differential Pair "J16_SIO17+" XMC Site 1 Rear I/O Differential Pair "J16_SIO17-" XMC Site 1 Rear I/O Differential Pair "J16_SIO18+" XMC Site 1 Rear I/O Differential Pair "J16_SIO18-" Acromag, Inc. Tel: 248-295-0310 - 52 - SEARAY Pin E12 E13 D6 D5 E3 E2 E4 E5 J7 J8 G3 G4 H18 H17 J3 J4 D9 D10 E10 E11 F13 F14 H9 H10 D13 D14 E14 E15 K13 K14 E16 E17 D17 D18 E18 E19 K17 K18 www.acromag.com ACEX-FP-IO-0x User’s Manual J16_DP00_P J16_DP00_N J16_DP01_P J16_DP01_N J16_DP02_P J16_DP02_N J16_DP03_P J16_DP03_N J16_DP04_P J16_DP04_N J16_DP05_P J16_DP05_N J16_DP06_P J16_DP06_N J16_DP07_P J16_DP07_N J16_DP08_P J16_DP08_N J16_DP09_P J16_DP09_N J16_DP10_P J16_DP10_N J16_DP11_P J16_DP11_N J16_DP12_P J16_DP12_N J16_DP13_P J16_DP13_N J16_DP14_P J16_DP14_N J16_DP15_P J16_DP15_N J16_DP16_P J16_DP16_N J16_DP17_P J16_DP17_N J16_DP18_P J16_DP18_N J16_DP19_P J16_DP19_N COM Express Front Panel for Ruggedized/Military Packaging XMC Site 1 Rear I/O Differential Pair "J16_DP00+" XMC Site 1 Rear I/O Differential Pair "J16_DP00-" XMC Site 1 Rear I/O Differential Pair "J16_DP01+" XMC Site 1 Rear I/O Differential Pair "J16_DP01-" XMC Site 1 Rear I/O Differential Pair "J16_DP02+" XMC Site 1 Rear I/O Differential Pair "J16_DP02-" XMC Site 1 Rear I/O Differential Pair "J16_DP03+" XMC Site 1 Rear I/O Differential Pair "J16_DP03-" XMC Site 1 Rear I/O Differential Pair "J16_DP04+" XMC Site 1 Rear I/O Differential Pair "J16_DP04-" XMC Site 1 Rear I/O Differential Pair "J16_DP05+" XMC Site 1 Rear I/O Differential Pair "J16_DP05-" XMC Site 1 Rear I/O Differential Pair "J16_DP06+" XMC Site 1 Rear I/O Differential Pair "J16_DP06-" XMC Site 1 Rear I/O Differential Pair "J16_DP07+" XMC Site 1 Rear I/O Differential Pair "J16_DP07-" XMC Site 1 Rear I/O Differential Pair "J16_DP08+" XMC Site 1 Rear I/O Differential Pair "J16_DP08-" XMC Site 1 Rear I/O Differential Pair "J16_DP09+" XMC Site 1 Rear I/O Differential Pair "J16_DP09-" XMC Site 1 Rear I/O Differential Pair "J16_DP10+" XMC Site 1 Rear I/O Differential Pair "J16_DP10-" XMC Site 1 Rear I/O Differential Pair "J16_DP11+" XMC Site 1 Rear I/O Differential Pair "J16_DP11-" XMC Site 1 Rear I/O Differential Pair "J16_DP12+" XMC Site 1 Rear I/O Differential Pair "J16_DP12-" XMC Site 1 Rear I/O Differential Pair "J16_DP13+" XMC Site 1 Rear I/O Differential Pair "J16_DP13-" XMC Site 1 Rear I/O Differential Pair "J16_DP14+" XMC Site 1 Rear I/O Differential Pair "J16_DP14-" XMC Site 1 Rear I/O Differential Pair "J16_DP15+" XMC Site 1 Rear I/O Differential Pair "J16_DP15-" XMC Site 1 Rear I/O Differential Pair "J16_DP16+" XMC Site 1 Rear I/O Differential Pair "J16_DP16-" XMC Site 1 Rear I/O Differential Pair "J16_DP17+" XMC Site 1 Rear I/O Differential Pair "J16_DP17-" XMC Site 1 Rear I/O Differential Pair "J16_DP18+" XMC Site 1 Rear I/O Differential Pair "J16_DP18-" XMC Site 1 Rear I/O Differential Pair "J16_DP19+" XMC Site 1 Rear I/O Differential Pair "J16_DP19-" Acromag, Inc. Tel: 248-295-0310 - 53 - F20 F19 G20 G19 F18 F17 J16 J15 H14 H13 G16 G15 J12 J11 F10 F9 G8 G7 G12 G11 K10 K9 F6 F5 J20 J19 H6 H5 K6 K5 H2 H1 E7 E6 F2 F1 K2 K1 E8 E9 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging LPC Signal Name LPC_AD0 LPC_AD1 LPC_AD2 LPC_AD3 LPC_FRAME# LPC_DRQ0# LPC_DRQ1# LPC_SERIRQ LPC_CLK Description LPC Multiplexed Address - Command and Data Bus 0 LPC Multiplexed Address - Command and Data Bus 1 LPC Multiplexed Address - Command and Data Bus 2 LPC Multiplexed Address - Command and Data Bus 3 LPC Frame Signal - LPC Cycle Start Indicator LPC Serial DMA Request Signal 0 LPC Serial DMA Request Signal 1 LPC Serial Interrupt Signal LPC Clock Output - 33MHz Nominal SEARAY Pin E46 E45 F46 F45 E43 D42 D41 E42 F42 I2C Signal Name I2C_CLK I2C_DAT Description General Purpose I2C Port Clock Output General Purpose I2C Port Data I/O Line SEARAY Pin E36 E35 Miscellaneous Signal Name SPKR WDTO FAN_PWM FAN_TACH Description Audio Enunciator Output - PC Beep Signal Watchdog Timer Output CPU Fan Speed Control CPU Fan Tach Input SEARAY Pin C35 C1 A23 A22 Power and System Management Signal Name PWRBTN# SYSRST# PLT_RST# SUS_STAT# SLP_S3# SLP_S4# SLP_S5# WAKE0# WAKE1# BATLOW# Description Power Button Input Signal System Reset Signal Platform Reset Signal Imminent Suspend Operation Indicator - Notifies LPC Devices Output Signal Indicating Suspend to RAM State Output Signal Indicating Suspend to Disk State Output Signal Indicating Soft Off State PCI Express Wake Signal General Purpose Wake Signal Low Battery Indicator for External Battery Acromag, Inc. Tel: 248-295-0310 - 54 - SEARAY Pin F41 E1 A24 C37 D40 D39 D38 G22 G21 C36 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Thermal Protection Signal Name COM_THRM# THRMTRIP3# Description Off-Module Temp Sensor Input Signal Indicating Over-Temp Condition Output Signal Indicating CPU Entered Thermal Shutdown SEARAY Pin D35 C34 SM Bus Signal Name SMB_CLK SMB_DATA SMB_ALERT# Description System Management Bus Bidirectional Clock Line System Management Bus Bidirectional Data Line System Management Bus Alert Signal SEARAY Pin E40 E39 E41 GPIO Signal Name GPI_0 GPI_1 GPI_2 GPI_3 GPO_0 GPO_1 GPO_2 GPO_3 SEARAY Pin D19 C20 B19 B20 B23 B24 E20 D20 Description General Purpose Input 0 General Purpose Input 1 General Purpose Input 2 General Purpose Input 3 General Purpose Output 0 General Purpose Output 1 General Purpose Output 2 General Purpose Output 3 Acromag, Inc. Tel: 248-295-0310 - 55 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging #23, 130 Pin 38999 keyed-B, Peripheral connector pin out (front view) Acromag, Inc. Tel: 248-295-0310 - 56 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging #23, 130 Pin 38999 keyed-A and C, I/O connector pin out (front view) Acromag, Inc. Tel: 248-295-0310 - 57 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging 38999 Crimping Tools If a Mating Cable Connector Kit (5028-558, 5028-559, 5028-560, or 5028-561) is purchased, the following list of tools will be needed to properly build the cable. These tools, as recommended by Amphenol, can be purchased from Daniel’s Manufacturing Corporation at www.dmctools.com. DMC Part # AF8 TH163 AFM8 K286 DAK225-22 DRK225-22 Description Crimp Tool for 12-size Pins 12 Gauge Turret-Head Crimp Positioner Miniature Crimp Tool for 23-size Pins 23-Size Crimp Positioner 23-Size Pin Installation Tool 23-Size Pin Removal Tool Acromag, Inc. Tel: 248-295-0310 Military Part # M22520/1-01 M22520/1-04 Notes Only required for 5028-561 Only required for 5028-561 M22520/2-01 M22520/2-12 - 58 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging PCB Mechanical Drawings Acromag, Inc. Tel: 248-295-0310 - 59 - www.acromag.com ACEX-FP-IO-0x User’s Manual Acromag, Inc. Tel: 248-295-0310 COM Express Front Panel for Ruggedized/Military Packaging - 60 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Bill of Materials The following Bill of Materials is only for the components listed on the Mechanical Drawings that have a fixed location. This reference is for customers that plan to design their own custom front panel boards that will mechanically fit in the ARCX 4000 enclosure. Bill of Materials Reference Description J3 J4 J5 J6 500P 200P J7 and J8 Power LED STATUS LED Size #23 38999 connector keyed-A Size #23 38999 connector keyed-B Size #23 38999 connector keyed-C Size #12 38999 connector keyed-A SEARAY 500 PIN CONNECTOR SEARAY 200 PIN CONNECTOR Header connector (for optional Power filter) Main power indicator LED, Blue System status LED, Multi-color Manufacture Manufacture P/N Amphenol Amphenol Amphenol Amphenol Samtec Samtec Samtec SunLED Kingbright 2M805-005-07ZNU23-130SA 2M805-005-07ZNU23-130SB 2M805-005-07ZNU23-130SC 2M805-005-07ZNU12-201SA SEAM-50-02.0-L-10-2-A-GP-K-TR SEAM-20-02.0-L-10-2-A-GP-K-TR HPF-04-01-T-S XLCBD11W WP3VEGW Schematic The schematic is available for download at http://www.acromag.com. Acromag, Inc. Tel: 248-295-0310 - 61 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Mezzanine Board Installation The connectors used to attach the mezzanine modules to the front panel board are offset and keyed to prevent incorrect installation. To install, align the four mounting holes with the attached standoffs on the front panel board. Attach board with M2.5 x 6mm screws on the four mounting holes. ACEX-FP-IO-02 ACEX-FP-IO-02 with ACEX-IO mezzanine boards installed on Site 1 and Site 2 Acromag, Inc. Tel: 248-295-0310 - 62 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging ACEX-FP-IO-01 ACEX-FP-IO-01 with ACEX-IO mezzanine board installed on Site 1 Acromag, Inc. Tel: 248-295-0310 - 63 - www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Certificate of Volatility Certificate of Volatility Acromag Model ACEX-FP-IO-01 ACEX-FP-IO-02 Manufacturer: Acromag, Inc. 30765 Wixom Rd Wixom, MI 48393 Volatile Memory Does this product contain Volatile memory (i.e. Memory of whose contents are lost when power is removed) □ Yes ■ No Type (SRAM, SDRAM, etc.) User Modifiable Function: Process to Sanitize: Size: □ Yes □ No Type (SRAM, SDRAM, etc.) Size: User Modifiable Function: Process to Sanitize: □ Yes □ No Non-Volatile Memory Does this product contain Non-Volatile memory (i.e. Memory of whose contents is retained when power is removed) □ Yes ■ No Type (EEPROM, Flash, etc.) Size: User Modifiable Function: Process to Sanitize: □ Yes □ No Type (EEPROM, Flash, etc.) Size: User Modifiable Function: Process to Sanitize: □ Yes □ No Type (EEPROM, Flash, etc.) Size: User Modifiable Function: Process to Sanitize: □ Yes □ No Other capabilities: Does device contain media storage capabilities: □ Yes ■ No If yes explain Is this device capable of wireless transmission: □ Yes ■ No If yes explain Acromag Representative Name: Joseph Primeau Title: Dir. of Sales and Marketing Acromag, Inc. Tel: 248-295-0310 Email: [email protected] - 64 - Office Phone: 248-624-1541 Office Fax: 248-624-9234 www.acromag.com ACEX-FP-IO-0x User’s Manual COM Express Front Panel for Ruggedized/Military Packaging Revision History The following table shows the revision history for this document: Release Date Version EGR/DOC 07 JAN 15 A MDW/ARP 01 JUL 15 B PDG/ARP Acromag, Inc. Tel: 248-295-0310 Description of Revision Initial Acromag release. Added 5028-566 and 5028-567 cables to order information. Reserved Pins 2 and 5 on J6 (Input power connector). - 65 - www.acromag.com