To measure current, you must break the circuit under test (cut a wire for example) and make the meter part of the circuit. This creates two connection points. On one side is the power source and the other is the load. If DC current is being measured, a minus sign will be displayed when current is flowing opposite to the connection polarity. 1. Ensure power is off to the circuit to be tested. 2. Set the rotary switch to the mA or 5A position (depending on the maximum possible amperage you will be measuring). The meter will default to the DC current setting. If you have an AC current source, press the “DC/AC” push-button to switch to AC. Th meter i n d i cates which mode you have selected at the far left of the display. 3. Create a break in the circuit as described earlier and connect the meter leads to the two points created at the break. 4. Apply power to the circuit and note your measurement value. WARNING! Do not remove the leads from the circuit until power is disconnected. Battery and Fuse Replacement When the battery icon appears in the upper right of the display, the batteries must be replaced immediately. Low battery voltage can cause incorrect readings and consequential damage. 1. To replace the batteries, remove the meter from its carrying case. 2. Slide the battery cover plate (on the back of meter) out. 3. Replace both batteries at once with type listed in the specifications. 4. Reassemble the meter. Fuse Replacement WARNING! Replace fuses with the type listed in the specifications (also printed on the circuit board) only. 1. To replace the fuses, remove the meter from its ca r rying case. 2. Slide the battery cover plate out (on the back of meter). 3. Remove the three back panel retaining screws and separate the two halves. Maintenance Periodic Service 4. Locate and replace expended fuse. • 5A near the bottom • .5A near the middle 5. Reassemble the meter. WARNING! Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in physical degradation of the meter. This could alter the protection from electrical shock and personal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do. These guidelines will help you attain long and reliable service from your meter: • Calibrate your meter annually to ensure it meets original performance specifications • Keep your meter dry. If it gets wet, wipe dry immediately Liquids can degrade electronic circuits • Whenever practical, keep the meter away from dust and dirt that can cause premature wear • Although your meter is built to withstand the rigors of daily use, it can be damaged by severe impactsUse reasonable caution when using and storing the meter Specifications NOTE: Accuracy is stated as ± (% of reading + number of least significant digits) at 32 to 104˚F, with relative humidity up to 80%. Stated accuracy is valid for a period of one year after calibration. AC conversions of this meter are average responding and calibrated to the RMS value of a pure sine wave input. DC Voltage Range Resolution Accuracy 300 mV 0.1 mV ±(1.2% + 2 digits) 3V .001 V ±(0.5% + 2 digits) 30 V .01 V ±(1.2% + 2 digits) 300 V .1 V 750 V 1V ±(1.5% + 3 digits) Resolution Accuracy Protections 1000 V AC Voltage Cleaning Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components. Range 3V .001 V 30 V .01 V 300 V .1 V 750 V 1V Protections ±(2.0% + 3 digits) 1000 V ±(2.0% + 4 digits) Clean the input terminals as follows: 1. Turn the meter off and remove all test leads. 2. Shake out any dirt that may be in the terminals. 3. Soak a new swab with alcohol and work the swab around in each terminal. DM5B-MAN P. 3