Chapter 1
PID Control Toolkit Overview
This example uses an integrating process with added noise, valve dead band, lag, and dead time.
This simple example does not account for time; thus, it does not correct itself for loop cycle time.
This example also demonstrates switching from automatic to manual mode.
PIDDAQ
PIDDAQ is a real controller for a resistor-capacitor network. It requires a National Instruments
I/O board and the resistor-capacitor network detailed on the user interface panel. It uses a single
conventional PID loop to control the output voltage of the resistor-capacitor network. The PID
tuning parameters are available on the panel for modification at run time.
Figure 1-4. Front Panel of the Resistor-Capacitor Network Example
LDLGDEMO
LDLGDEMO demonstrates the Lead-Lag functions. It requires no plug-in boards or external
hardware. Input for the Lead-Lag function is either a sine wave or a square wave. The
waveform is synchronized to the Cycle Time chosen. Varying the tuning parameters
demonstrates the time-domain response of the Lead-Lag functions. Notice that a large Lead
© National Instruments Corporation
1-13
LabWindows/CVI PID Control Toolkit