Download 5 DDEC FEATURES - Wanderlodge Gurus

Transcript
DDEC IV APPLICATION AND INSTALLATION MANUAL
The pin definition for the connector, current, and wire gage are listed in Table 5-17.
Current
Terminals
Wire Gauge
Under 5 Amps
1-2, 7-12
16 AWG
5 - 10 Amps
1-2, 7-12
14 AWG
--
3-6
18 - 20 AWG
Table 5-17
Wire Gauge for ESSE-2
The electrical input voltage options for ESSE-2 are listed in Table 5-18.
Input Voltage
Option
Max. Operating
Current
Max. Standby
Current
8 - 40 VDC
40 - 80 VDC
At 40 V: 250 MA
At 80 V: 115 MA
At 24 V: 220 MA
At 64 V: 100 MA
At 12 V: 200 MA
At 40 V: 50 MA
At 40 V: 70 MA
At 80 V: 75 MA
At 40 V: 45 MA
At 64 V: 60 MA
At 40 V: 30 MA
At 40 V: 50 MA
0.1 to 10 Amps - 28 VDC Resistive Load
0.1 to 4 Amps - 75 VDC Resistive Load
0.1 to 8 Amps - 28 VDC Inductive Load
0.1 to 3 Amps - 75 VDC Inductive Load
Power Supply
Transient
Protection
900 VDC for 100 microseconds
Exponential Decay
140 VDC for 1 milliseconds
Exponential Decay
110 VDC for 0.45 seconds
Exponential Decay
900 VDC for 100 microseconds
Exponential Decay
140 VDC for 1 milliseconds
Exponential Decay
110 VDC for 0.45 seconds
Exponential Decay
Reverse Polarity
Protection
1000 VDC
1000 VDC
Relay Contact
Ratings
Table 5-18
ESSE-2 Electrical Input Voltage Options
All information subject to change without notice. (Rev. (Rev. 3/02))
7SA742 0203 Copyright © 2002 DETROIT DIESEL CORPORATION
5-37