Transcript
2 Parameter detailed description P= 60f 60×50 = =2.054 N 1460 It means that the motor has 2 pairs of poles (4 poles motor). 1: 2 poles 2:4 poles 3: 6 poles 4: 8 poles P13.22 Motor2 rated speed Coding RW US ■ ■ Range 1rpm~18000rpm Default 1460rpm Change mode Stop Only PT ND PS The motor rated speed should be set at the asynchronous machine nameplate value for rated speed. If set P13.22 to 0, the value of P13.21 (Number of motor 2 pole-pairs) is 2 by default. If set P13.22 to other number, the drive will automatically calculate the number of motor 2 pole-pairs and the value of P13.21 will be changed to 0 automatically. P13.23 Motor2 stator resistance Coding RW US PT ■ ■ ■ Range 0.000Ω~60.000Ω Default 0 Change mode ND PS Stop Only After an autotune is carried out, the drive will refresh the parameter automatically. P13.24 Reserved P13.25 Reserved RW US PT ND PS RW US PT ND PS ■ ■ ■ Coding Range Default Change mode P13.26 Coding Motor2 transient inductance Range 0.00%~50.00% Default By model Change mode Stop Only ...UVtech HD700 Advance User Manual... Page 147 of 225