Transcript
Pre-defined Templates 11.11.3 SSU Type IV Expressed as MTIE Standard: Draft ITU-T Recommendation G.812 (09/97) File name: SHORT TRANSIENT SSU IV G812.mti Object to which the specification applies: Synchronisation Supply Unit (SSU) Type IV Specified quantity and measurement conditions: The phase transient response at the output of a Synchronisation Supply Unit Type IV must meet this mask when the currently selected input reference is lost and a second reference, traceable to the same reference clock, is selected instead. Mathematical description (as specified in the standard): MTIE 61 000 τ 1000 Observation Interval 0.00133 < τ < 0.0164 τ > 0.0164 Template (circles = points stored in the WinSTS template file): MTIE [s] 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.0E-02 1.0E-01 1.0E+00 1.0E+01 1.0E+02 1.0E+03 Observation Interval [s] Comments: This mask is applicable to 1544 kbit/s interfaces. A different mask applies to STM-N interfaces - see Draft ITU-T Rec. G.812 (09/97). OSA 5565 User Manual Revision A April 2010 11-28