Description of the Function Modules
Directory MDX_InverterParameters
Outputs
4
The function module MC_SetJerk_MDX has the following outputs:
Output
Type
Description
Done
BOOL
This output shows whether the jerk time has been transferred.
• TRUE: The jerk time has been transferred from the MOVI-PLC®
controller to the drive inverter.
• FALSE: The jerk time has not been transferred.
Busy
BOOL
This output shows whether the jerk time is being transferred.
• TRUE: The jerk time is being transferred.
• FALSE: The jerk time is not being transferred at present.
Error
BOOL
This output shows whether an error as occurred in the function module.
• TRUE: An error has occurred during the transfer of the jerk time.
• FALSE: No error has occurred.
ErrorID
DWORD
This output displays the error code of the error (→ page 68).
Axis
AXIS_REF
This output displays the axis reference.
Note:
The function module MC_SetJerk_MDX changes the ramp type of the drive inverter
from a linear ramp to a jerk-limited ramp. For speed-controlled travel tasks, the drive
inverter automatically uses a linear ramp. When the drive inverter then executes a
positioning task, it automatically switches back to the jerk-limited ramp.
If you set the JerkTime input to 0, the function module MC_SetJerk_MDX switches the
ramp type back to linear again.
Manual – MPLCMotion_MDX Library