Description of the Function Modules
Directory MDX_InverterParameters
Outputs
4
The function module MC_SetLimiter_MDX has the following outputs:
Output
Type
Description
Done
BOOL
This output shows whether the parameter has been transferred.
• TRUE: The parameter has been transferred from the MOVI-PLC®
controller to the drive inverter.
• FALSE: The parameter has not been transferred.
Busy
BOOL
This output shows whether the parameter is being transferred.
• TRUE: The parameter is being transferred.
• FALSE: The parameter is not being transferred at present.
Error
BOOL
This output shows whether an error as occurred in the function module.
• TRUE: An error has occurred during parameter transfer.
• FALSE: No error has occurred.
ErrorID
DWORD
This output displays the error code of the error (→ page 68).
Axis
AXIS_REF
This output displays the axis reference.
Manual – MPLCMotion_MDX Library