Download M30201 Group USER`S MANUAL

Transcript
Mitsubishi microcomputers
M30201 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Timer A
Selecting timer mode and functions
b7
b0
0
0
1
0
Timer A0 mode register [Address 039616]
TA0MR
0
Selection of timer mode
Pulse output function select bit (Note)
1 : Pulse is output (TA0OUT pin is a pulse output pin)
Gate function select bit
b4 b3
00:
01:
Gate function not available (TA0IN pin is a normal port pin)
0 (Must always be “0” in timer mode)
Count source select bit
b7 b6
b7 b6
0 0 : f1
0 1 : f8
1 0 : f32
1 1 : fC32
Count source period
Count
source f(XIN) : 10MHZ f(XcIN) : 32.768kHZ
0
0
f1
100ns
0
1
f8
800ns
1
0
f32
1
1
fC32
3.2µs
976.56µs
Note: Set the corresponding port direction register to “1” (output mode).
Setting divide ratio
(b15)
b7
(b8)
b0 b7
b0
Timer A0 register [Address 038716, 038616] TA0
Can be set to 000016 to FFFF16
Setting clock prescaler reset flag
(This function is effective when fC32 is selected as the count source. Reset the prescaler for generating fC32 by
dividing the XCIN by 32.)
b7
b0
Clock prescaler reset flag [Address 038116]
CPSRF
Clock prescaler reset flag
0 : No effect
1 : Prescaler is reset (When read, the value is “0”)
Setting count start flag
b7
b0
Count start flag [Address 038016]
TABSR
Timer A0 count start flag
Start count
Figure 2.2.11. Set-up procedure of timer mode, pulse output function selected