17.3 Table of High-level Instructions
(S)→(D)
S, D
(S+1, S)→(D+1, D)
S, D
S, D
S, D
S, n,
D
*1
7
5
(S+1, S)→(D+1, D)
7
The specified one bit in “S” is transferred to
the specified one bit in “D”. The bit is
specified by “n”.
F6
Hexadecimal
DGT
S, n, d The specified one digit in “S” is transferred
P6
digit (4-bit)
PDGT
to the specified one digit in “D”. The digit is
data move
specified by “n”.
F7
Two 16-bit
MV2
S1,
(S1)→(D),
P7
data move
PMV2
S2, D
(S2)→(D+1)
F8
Two 32-bit
DMV2
S1,
(S1+1, S1)→(D+1, D),
P8
data move
PDMV2
S2, D
(S2+1, S2)→(D+3, D+2)
F10
Block move
BKMV
S1,
The data between “S1” and “S2” is
P10
PBKMV
S2, D
transferred to the area starting at “D”.
F11
Block copy
COPY
S, D1,
The data of “S” is transferred to the all area
P11
PCOPY
D2
between “D1” and “D2”.
F12
Data read
ICRD
S1,
The data stored in the expansion memory
from EEPS2, D
of the EEP-ROM specified by “S1” and “S2”
ROM
are transferred to the area starting at “D”.
P13
Data write to
PICWT
S1,
The data specified by “S1” and “S2” are
EEP-ROM
S2, D
transferred to the EEP-ROM starting at “D”.
F12
Data read
ICRD
S1,
The data stored in the expansion memory
from F-ROM
S2, D
of the F-ROM specified by “S1” and “S2”
are transferred to the area starting at “D”.
P13
Data write to
PICWT
S1,
The data specified by “S1” and “S2” are
F-ROM
S2, D
transferred to the F-ROM starting at “D”.
F12
Data read
ICRD
S1,
The data stored in the expansion memory
P12
from IC card
PICRD
S2, D
of the IC card specified by “S1” and “S2”
are transferred to the area starting at “D”.
F13
Data write to
ICWT
S1,
The data specified by “S1” and “S2” are
P13
IC card
PICWT
S2, D
transferred to the IC card expansion
memory area starting at “D”.
F14
Program read PGRD
S
The program specified using “S” is
P14
from IC
PPGRD
transferred into the CPU from IC memory
memory card
card and executes it.
: Available,
: Not available,
: Not available partially
*1) This instruction is available for FP2/FP2SH Ver. 1.5 or later.FP10SH cannot be used
*2) This instruction is available for FP0 Ver. 2.0 or later and FP-e.
*1
5
(S)→(D)
The head word No. of the specified slot is
read.
FP2SH/FP10SH
S, D
FPΣ
Description
rand
FP2
Data transfer instructions
F0
16-bit data
MV
P0
move
PMV
F1
32-bit data
DMV
P1
move
PDMV
F2
16-bit data
MV
P2
invert and
PMV/
move
F3
32-bit data
DMV/
P3
invert and
PDMV/
move
F4
Reading of
GETS
P4
head word
PGETS
No. of the
specified slot
F5
Bit data
BTM
P5
move
PBTM
Ope-
FP-X
Boolean
FP0R
Name
FP0/FP-e
Number
Steps
The high-level instructions are expressed by the prefixes “F” or “P” with numbers. For most of the high-level
instructions, “F” and “P” types are available. The differences between the two types are explained as follows:
- Instructions with the prefix “F” are executed in every scan while its trigger is in the on.
- Instructions with the prefix “P” are executed only when the leading edge of its trigger is detected.
For the FP0/FP0R/FPΣ/FP-X, the P type high-level instructions are not available.
5
7
7
7
11
7
7
11
11
*2
*2
11
11
11
11
3