17.3 Table of High-level Instructions (S)→(D) S, D (S+1, S)→(D+1, D) S, D S, D S, D S, n, D *1 7 5 (S+1, S)→(D+1, D) 7 The specified one bit in “S” is transferred to the specified one bit in “D”. The bit is specified by “n”. F6 Hexadecimal DGT S, n, d The specified one digit in “S” is transferred P6 digit (4-bit) PDGT to the specified one digit in “D”. The digit is data move specified by “n”. F7 Two 16-bit MV2 S1, (S1)→(D), P7 data move PMV2 S2, D (S2)→(D+1) F8 Two 32-bit DMV2 S1, (S1+1, S1)→(D+1, D), P8 data move PDMV2 S2, D (S2+1, S2)→(D+3, D+2) F10 Block move BKMV S1, The data between “S1” and “S2” is P10 PBKMV S2, D transferred to the area starting at “D”. F11 Block copy COPY S, D1, The data of “S” is transferred to the all area P11 PCOPY D2 between “D1” and “D2”. F12 Data read ICRD S1, The data stored in the expansion memory from EEPS2, D of the EEP-ROM specified by “S1” and “S2” ROM are transferred to the area starting at “D”. P13 Data write to PICWT S1, The data specified by “S1” and “S2” are EEP-ROM S2, D transferred to the EEP-ROM starting at “D”. F12 Data read ICRD S1, The data stored in the expansion memory from F-ROM S2, D of the F-ROM specified by “S1” and “S2” are transferred to the area starting at “D”. P13 Data write to PICWT S1, The data specified by “S1” and “S2” are F-ROM S2, D transferred to the F-ROM starting at “D”. F12 Data read ICRD S1, The data stored in the expansion memory P12 from IC card PICRD S2, D of the IC card specified by “S1” and “S2” are transferred to the area starting at “D”. F13 Data write to ICWT S1, The data specified by “S1” and “S2” are P13 IC card PICWT S2, D transferred to the IC card expansion memory area starting at “D”. F14 Program read PGRD S The program specified using “S” is P14 from IC PPGRD transferred into the CPU from IC memory memory card card and executes it. : Available, : Not available, : Not available partially *1) This instruction is available for FP2/FP2SH Ver. 1.5 or later.FP10SH cannot be used *2) This instruction is available for FP0 Ver. 2.0 or later and FP-e. *1 5 (S)→(D) The head word No. of the specified slot is read. FP2SH/FP10SH S, D FPΣ Description rand FP2 Data transfer instructions F0 16-bit data MV P0 move PMV F1 32-bit data DMV P1 move PDMV F2 16-bit data MV P2 invert and PMV/ move F3 32-bit data DMV/ P3 invert and PDMV/ move F4 Reading of GETS P4 head word PGETS No. of the specified slot F5 Bit data BTM P5 move PBTM Ope- FP-X Boolean FP0R Name FP0/FP-e Number Steps The high-level instructions are expressed by the prefixes “F” or “P” with numbers. For most of the high-level instructions, “F” and “P” types are available. The differences between the two types are explained as follows: - Instructions with the prefix “F” are executed in every scan while its trigger is in the on. - Instructions with the prefix “P” are executed only when the leading edge of its trigger is detected. For the FP0/FP0R/FPΣ/FP-X, the P type high-level instructions are not available. 5 7 7 7 11 7 7 11 11 *2 *2 11 11 11 11 3 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Related documents
User's Manual
USER`S MANUAL
FP-X PLCs - Datasheet.su
FP-Sigma User`s Manual
58 Adjustable Speed Drive Controllers
Panasonic FP0R Series PLCs User`s Manual
Manual - Spectrum Controls, Inc.
On-Chip Monitoring for Non- Intrusive Hardware/Software
FP-SIGMA User`s Manual
GT Series Technical Manual - Q-TECH
FP7 User`s Manual (SCU communication)
5 V DC type GT01 - Autopack Co Ltd