Download US - Aqua Lung
Transcript
97 4.14 Microphone Assembly Adjustment NOTE - The 103022 thru 103025 masks use the modified M-169A/AIC 5-ohm microphone. Refer to the following for informational guidance on how to achieve optimum voice and speech intelligibility performance of the mask-mounted microphone. This information applies to the GENTEX modified M-169A/AIC microphone (9). 1. When viewing into the internal mask cavity, the microphone element should have the word “FRONT” facing the aircrew member, indicating “talk side” (Ref. Figure 4-7a). 2. To achieve best operating performance, the microphone element should be positioned no more than 6.4 mm (¼ inch) away from the lips. Additionally, the element should be centered between the inhalation and exhalation valves (Ref. Figures 4-18 and 4-19). 3. Some wearers may experience slight discomfort if the microphone element is touching their lips and mouth. This can be remedied by moving the element from side to side within the mask cavity. Background noise may be picked up in the communication system if the element is placed directly over the inhalation or exhalation valve. ¼” Max FRONT Figure 4-18 Figure 4-19 Microphone Assembly “Talk Side” Microphone Assembly Positioning (Modified M-169A/AIC) (Modified M-169A/AIC Shown)