Download Tricon Elevator Control User Guide
Transcript
Final Test Bottom Floor Test Procedure Danger If the car has a counterweight safety, ensure that the safety will not apply by tying down the safety actuating arm prior to performing this test. Failure to prevent the safety from applying may result in the safety applying while the buffer is compressed. 1. Access the Parking Floor parameter (#141) in the Setup/Parameters menu. 2. Change this parameter to the bottom floor. Step 2 commands the car to run to the bottom floor. When the car reaches the bottom terminal floor, it will not slow down. The ETS system will trip, stopping the car. 3. After completing the test, remove the drive jumper and any tiedown that may have been placed on a safety. 4 4-25