Download ATPDraw - Electrical & Computer Engineering

Transcript
Reference Manual
Mechanical network:
* Shaft mass (moment of inertia) <-> Capacitance
( 1kg/m2 <-> 1 Farad )
* Shaft section (spring constant) <-> Inverse inductance.
( 1 Nm/rad <-> 1/Henry )
* Shaft friction (viscous damping) <-> Conductance.
( 1 Nm/rad/s <-> 1/ohm )
* Angular speed <-> Voltage
(1 rad/s <-> 1 Volt )
* Torque <-> Current
(1 Nm <-> 1 Amp )
* Angle <-> Charge
(1 rad <-> 1 Coulomb )
L1
__
__
____ ___oooo_______________
| |
| |
|
|
|
|
|
|J1| K1 |J2| --> T
_|_
<
_|_
<
|
==| |=====| |====
====>
___C1 >R1
___C2 >R2 O I
| |
| |
|
<
|
<
|
|__|
|__|
|
|
|
|
|
D1
D2
C1=J1, C2=J2, R1=1/D1, R2=1/D2, L1=1/K1, I=T
4.2.9.9 Transformers
Fig. 4.49 - Available transformer models
The popup menu under Transformers contains the following items:
Selection
Object name
Sat. 1 phase
TRAFO_S
Icon
ATP card
Description
BRANCH
Single phase saturable transformer.
TRANSFORMER
Ide. 1 phase
TRAFO_I
SOURCE
type 18
Single phase ideal transformer.
Sat. /Y 3 ph
TRADY_3
BRANCH
3x1-phase saturable transformer.
D/Y coupled windings. 3-phase node.
Sat. Y/ 3 ph
TRAYD_3
TRANSFORMER
BRANCH
TRANSFORMER
ATPDraw version 1 for Windows
3x1-phase saturable transformer.
Y/D coupled windings. 3-phase node.
97