Predictive Analysis 6-2 p 2 Φ min + δ Φ min p 1 Figure 6.1. Objective function contours in parameter space; linear model. p 2 Φ min + δ Φ min p 1 Figure 6.2. Objective function contours in parameter space; nonlinear model. Both of Figures 6.1 and 6.2 depict situations where there is a high degree of parameter correlation – that is, one parameter can be varied in harmony with another with virtually no effect on the objective function. Thus the solution to the inverse problem (ie. the model calibration problem) is nonunique. If the minimum of the objective function is denoted as Φmin, and if all parameters for which the objective function is less than Φmin + δ (where δ is relatively small) can also be considered to calibrate the model, then the range of parameter values which can be considered to calibrate the model can be quite large indeed. In Figures 6.1 and 6.2 the set of “allowable parameter values” (from the model calibration point of view) occupies the area that lies within the Φmin + δ contour in parameter space. In most instances of model calibration, only a single set of parameters lying within the Φmin + δ contour of Figures 6.1 and 6.2 is calculated. Model predictions are then made with this single parameter set. An obvious question is this: what would have been the model’s