Download NaftaPOS software
Transcript
NAFTAPOS POS SYSTEM SOFTWARE FOR PETROL STATIONS Revision: R07 Review date: 21 June, 2015 Response type: if “OK” – successful, else – various errros Quantity of received responses Selection of the pump number Test of communication with PTS controller In configuration of “PTS controller” driver only logical addresses of dispensers are set, the physical address of the connected fueling place is specified in PTS controller configuration utility. Notice! Due to a reason of constant development of PTS controller and adding to it communication protocols of new fuel dispensers and ATG systems PTS controller configuration utility is also constantly being developed. That is why in order to have the latest version of the configuration utility and the latest firmware of the PTS controller – request it from “TECHNOTRADE LTD” company. Location of PTS controller configuration utility is NaftaPOS\Pts_config\”. Linking of pump windows numbers to logical addresses of fuel dispensers set in PTS controller configuration utility is made on tab “Pumps” of PTS controller driver: Selection of the logical pump address in PTS controller to be polled (linking to pump in NaftaPOS system) Enabling flexible setting for each of the pumps in NaftaPOS system Flexible setting for each of the pumps in NaftaPOS system Pumps in NaftaPOS system Selecting nozzles for each of the pumps in NaftaPOS system NaftaPOS configuration tool – PTS controller driver configuration, tab “Pumps” Field “Nozzles mask” serves for specification of what nozzles are enabled in selected pump (for normal operation all checkboxes should be checked). Flexible settings are used to enable/disable individual settings for each of the pumps. www.technotrade.ua page 33 from 134