Download ENDA EUC742 PID UNIVERSAL CONTROLLER
Transcript
Depth DIMENSIONS 97mm EUC 742 2 78mm 72mm PV SV CNT/AL2 AN/SSR AL1 SET CSET ASET ENDA UNIVERSAL CONTROLLER Connection Cables 2 75mm +0.7 68 mm mm 1 1 Panel cut-out For removing mounting clamps: - Push the flush-mounting clamp in direction 1 as shown in the figure left. - Then, pull out the clamp in direction 2. 68 +0.7 Flush mounting clamp 84mm Panel Rubber packing Note 1) While panel mounting, additional distance required for connection cables should be considered. 2) Panel thickness should be maximum 10mm. 3) If there is no 90mm free space at back side of the device, it would be difficult to remove it from the panel. CONNECTION DIAGRAM ENDA EUC742 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of energy. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. The installation and electrical connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. 11 2 2+ A 3- B 5 14 6 5 15 6 + - ANL/SSR OUT AL1 AC 250V 2A RESISTIVE LOAD 7 16 8 17 9 14 15 16 Note 1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245. 2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the 17 + Pt 100 7 12 13 CONT./AL2 AC 250V 2A RESISTIVE LOAD RS-485 COM. 4 13 4 Logic output of the instrument is not electrically insulated from the internal circuits. Therefore, when using a grounding thermocouple, do not connect the logic output terminals to the ground. 11 RS- 485 12 3 230V AC +10% -20% 50/60Hz 7VA - TC (mA inp). SN: XXXXXXXXX 8 ENDA INDUSTRIAL ELECTRONICS 9 EUC742-230VAC-RS PID UNIVERSAL CONTROLLER Temperature compansation sensor NOTE : Fuse F 100 mA 250V AC SUPPLY : 184-253V or 99-121V AC 11 12 Holding screw 0.4-0.5Nm switch 230V ,110V or 24V AC Supply Line Neutral Fuse should be connected. Cable size: 1,5mm² + SENSOR INPUT : TC For J-K-T-S-R type thermocouple : Use suitable compensation cables. Don't use jointed cables. Pay attention to the polarities of the thermocouple cables as shown in the figure right are connected to the . For resistance thermometer : When 2 wired Pt 100 is used, terminals 7 and 8 must be short circuited. Equipment is protected throughout by DOUBLE INSULATION. 8 - 9 + 0-20mA or 4-20mA input - + 8 9 + - 7 Pt 100 8 9 SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu Barbaros Cd. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 5/5 url : www.enda.com.tr Order Code : EUC742- - 1 1- Supply Voltage 230VAC...230V AC 110VAC...110V AC 24VAC.....24V AC SM...........9-30V DC / 7-24V AC 2 2- Modbus Option RS........RS-485 Modbus communication None....Don’t support RS-485 Modbus communication EUC742-E-02-R