Download ENDA EUC742 PID UNIVERSAL CONTROLLER

Transcript
Depth
DIMENSIONS
97mm
EUC 742
2
78mm
72mm
PV
SV
CNT/AL2
AN/SSR
AL1
SET
CSET
ASET
ENDA
UNIVERSAL CONTROLLER
Connection
Cables
2
75mm
+0.7
68
mm
mm
1
1
Panel cut-out
For removing mounting clamps:
- Push the flush-mounting
clamp in direction 1 as
shown in the figure left.
- Then, pull out the clamp in
direction 2.
68
+0.7
Flush mounting
clamp
84mm
Panel
Rubber packing
Note 1) While panel mounting, additional distance required
for connection cables should be considered.
2) Panel thickness should be maximum 10mm.
3) If there is no 90mm free space at back side of the device,
it would be difficult to remove it from the panel.
CONNECTION DIAGRAM
ENDA EUC742 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are
connected to the device must be free of energy. The device must be protected against inadmissible humidity,
vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines
that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should
not be close to the power cables or components. The installation and electrical connections must be carried on by
a qualified staff and must be according to the relevant locally applicable regulations.
11
2
2+
A
3- B
5
14
6
5
15
6
+
-
ANL/SSR
OUT
AL1
AC 250V 2A
RESISTIVE
LOAD
7
16
8
17
9
14
15
16
Note 1) Mains supply cords shall meet
the requirements of IEC 60227 or
IEC 60245.
2) In accordance with the safety
regulations, the power supply
switch shall bring the identification
of the relevant instrument and it
should be easily accessible by the
17
+
Pt 100
7
12
13
CONT./AL2
AC 250V 2A
RESISTIVE
LOAD
RS-485
COM.
4
13
4
Logic output of the instrument is not
electrically insulated from the
internal circuits. Therefore, when
using a grounding thermocouple, do
not connect the logic output
terminals to the ground.
11
RS- 485
12
3
230V AC +10% -20%
50/60Hz 7VA
-
TC
(mA inp).
SN: XXXXXXXXX
8
ENDA INDUSTRIAL ELECTRONICS
9
EUC742-230VAC-RS
PID UNIVERSAL CONTROLLER
Temperature compansation
sensor
NOTE :
Fuse
F 100 mA
250V AC
SUPPLY :
184-253V or
99-121V AC
11
12
Holding screw
0.4-0.5Nm
switch
230V ,110V or 24V AC
Supply
Line
Neutral
Fuse should
be connected.
Cable size: 1,5mm²
+
SENSOR INPUT :
TC
For J-K-T-S-R type thermocouple :
Use suitable compensation cables. Don't use
jointed cables. Pay attention to the polarities
of the thermocouple cables as shown in the
figure right are connected to the .
For resistance thermometer :
When 2 wired Pt 100 is used, terminals 7
and 8 must be short circuited.
Equipment is protected throughout
by DOUBLE INSULATION.
8
-
9
+
0-20mA or
4-20mA input -
+
8
9
+
-
7
Pt 100
8
9
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cd. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
5/5
url : www.enda.com.tr
Order Code : EUC742-      - 
1
1- Supply Voltage
230VAC...230V AC
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
2
2- Modbus Option
RS........RS-485 Modbus communication
None....Don’t support RS-485 Modbus communication
EUC742-E-02-R