Download User`s manual

Transcript
User's manual TopGun 3
Part No. 7500.TG3
_
3. Remove the filter nozzle.
For this purpose, insert a screwdriver between the filter nozzle and the locking ring.
4. Push the filter nozzle forwards (see sketch).
5. Fit a new filter and press it into place.
Faults
Problem
Gun is not blowing
No ionisation
(LED in gun does not light
up)
Table 1: faults
Cause
No (mains) voltage
No compressed air
Filter nozzle clogged
No (mains) voltage
Defective power unit
Remedy
Restore (mains) voltage
Restore compressed air
supply
Replace filter nozzle
Restore (mains) voltage
Repair the power unit
Repair
Warning:
Repairs shall be made by a skilled electrical engineer.
When opening the power unit, you may touch parts under hazardous voltage. We
recommend you to return the complete installation (gun + power unit) if there is a need for
repair. Pack them properly and clearly state the reason for return.
Seite 6 von 6
V0503