Download Important - Advanced Energy
Transcript
Advanced Energy® AE 500 Inverter Appendix B System and Mechanical Diagrams SYSTEM DIAGRAM MAIN COMPARTMENT DC CONTACTOR Load-Break Rated 2 POS_I N POS_OUT NEG_I N NEG_OUT Bulk 3 4 DC- Line LINE AC Disc Status 3 PHASE CONTACTOR P OWER GROUND 3 x 600VAC, 7.5A AC Cont GFI ISOLATION XFMR Y:Y 480, 600V INSTALLER LANDINGS 480/600Vac 3 Phase, 60Hz 500kW to Grid/Utility CONTACTOR P OWER Adjacent Phase DC Cont Ctrl AC DISCONNECT Load Rated LOAD 3 x 600VAC, 10A Array Current Measure Neg/Pos Gnd Select By Assy AC Cont Status SWITCHING INDUCTORS DC+ Shunt DC HOT CONTACTOR P OWER Snubber PW M V DC IA C Temp Error 1 AC CONTACTOR Load Rated AC FILTER IPM DC FILTER DC Cont Status MAIN COMPARTMENT MAGNETICS COMPARTMENT DC COLD 1 ph HK Xfmr AC Precharge Ctrl 160V CTRL + Bleeder CTRL - AC SURGE CTRL + CTRL - Bleeder Disable 600V Phase A Phase B 120V 480V 600VAC, 3A CTRL + Precharge DC Precharge Ctrl LVRT CTRL - 7.5A CONTACTOR P OWER L1 L2 3A GND GFDI DC Surge Status 24V SUPPLY 24V Power Supply PV Voltage Measure DC SURGE L1 AC Cont Ctrl DC+ DC- UL508A Panel Power Power Good Power Status 1 24V Power Supply GFDI Status 600VDC, 5A AC Surge Status INVERTER BACKPLANE AC Cont GFI L2 3A GND Revenue Grade Meter, Input Power 3x600VAC, 0.1A DC+ DCPower Good Revenue Grade Meter, Line Voltage Measurement Power Status 2 GF Current Measure Utility Volts Measure Utility Current Measure INVERTER BACKPLANE INVERTER BACKPLANE ELECTRONICS COMPARTMENTS DISABLE DC COLD AC Disc Status DC NEG DC COLD CKT1 PW M Co n tr o ller REVERSED IN + GND SYSTEMS 2 4 2 24VTO IPMs (3) COMBINER OPTIONS Power Status 1 OPTION 3 20 X 225A BREAKERS NOT MONITORED AC Cont Ctrl DC Cont Ctrl AC Precharge Ctrl DC Precharge Ctrl SW1 LINK Blower Remote Disable Fast Remote Disable Slow 3 x 600VAC 3A 5V Blower 48V 3 x 600VAC 3A 24V ACT 48V 10V 250V, 5A 1 3 Ph Auto Po w er Dis t. OPTION 2 8 X 400A BREAKERS MONITORED GFDI Status ON- 2 Modbus Address, 8-pole DIP Modbus Termination, 4-pole DIP 3 x 600VAC, 7.5A Power Status 2 GROUND SW2 Modbus 3-2 24V DC Surge Status Bleeder Disable 3 ON+ Output Flag 1, Running Output Flag 2, Fault AC Surge Status DC COLD CKTn 250V, 0.2A OPTIONAL REVENUE-GRADE POWER METER Modbus 3 Modbus Meter 120V Power In MBUS 10V STAT 5V Modbus UL508 Modbus 1-2 RJ45 POST 3 Phase Current Sense 250V, 3A (3) Service Com Port AC Cont Status DC Cont Status 24V USER 120V Power In FAULT 24V CONTROL 250V, 3A 3 Phase V oltage Sense PAUSE / SCROLL 250V, 3A Us er In ter fac e OK DC HOT CKTn OPTION 1 16 X 225A BREAKERS MONITORED 24V SUPPLY Po w er Dis t. VFD, 4x20 Character USER BACKPLANE TA CH PW M Circuit Breakers See Tables In v er ter In ter fac e DC PO S DC HOT CKT1 INVERTER BACKPLANE Co m m DC HOT TA CH PW M INSTALLER LANDINGS 295-595Vdc, 600Vmax 3500A Max Array Short Circuit Current RJ45 OPTIONAL UL508A PANEL Modbus 1 Modbus IN FROM PREVIOUS INVERTER Modbus OUT TO NEXT INVERTER Figure 10‑1. AE 500 system diagram 570-1001791-05A System and Mechanical Diagrams B‑1