Operation Manual – Configuration Examples U-SYS SoftX3000 SoftSwitch System z Chapter 1 Subscriber Access Networking Check whether the data configuration at AMG side is correct if the data at SoftX3000 side is configured correctly. 1.8 Configuring Data for Interconnecting with UMG8900 (Connected with RSP Subscriber Frame Device) 1.8.1 Introduction I. Typical networking model When a UMG8900 serves as AMG, it can access Huawei RSP subscriber frame device through E1 and provide large-capacity analog or digital subscriber line ports, so that operators can provide voice service and narrowband data service to subscribers through IP WAN. Figure 1-9 illustrates the typical networking model of UMG8900 serving as AMG (connected with RSP subscriber frame device). SoftX3000 IP MAN H.248 protocol UMG8900 Internal protocol/ E1 interface RSP subscriber frame Subscriber A Subscriber B Subscriber C Subscriber D Figure 1-9 UMG8900 AMG connected with RSP subscriber frame device In the networking mode as shown in Figure 1-9, RSP subscriber frame is invisible for SoftX3000. That is, when you configure data at SoftX3000 side, it is only required to take UMG8900 and RSP subscriber frame as one AMG adopting H.248 protocol. Huawei Technologies Proprietary 1-37