Transcript
• A three to six digit number representing the peak altitude in feet. • A long separator tone followed by a two to five digit number representing the maximum velocity during the flight in miles per hour. • If the “siren delay” number is set to a number greater than zero (default is 5 seconds, changeable in the setup menu of the download software), the altimeter will wait for the specified siren delay time, and then emit a 10 second warbling siren tone to aid in locating the rocket if it is hidden from sight in a tree, tall grass, etc. If you do not want this feature, set the Siren Delay setting to “0” and it will be disabled. • After a 10 second period of silence, the sequence repeats until power is disconnected. Flight data and peak altitude are preserved when power is turned off. Additional Useful Information Shear Pins Virtually all two event deployment rockets should be set up with shear pins at the separation points. Shear pins hold the rocket sections together until the ejection charge fires so that they don’t separate prematurely due to recoil or drag forces. If your drogue shock cord is too short, not elastic enough, or the drogue charge is overly energetic, there will be a considerable “jerk” placed on the cord when the drogue ejection charge fires. The forward section of the rocket will be ejected at high speed away from the aft section, and when the shock cord comes to full extension inertia will try to yank the 30