Download Release Notes 1.9.30_071010

Transcript
WinLink 1000 - Release 1.9.30
Release Notes
07-Oct-10
5 New Features
Feature
1.
VLAN
functionality
Independent
2. Clock per TDM
Trunk
3.
Ring protection
and Ethernet 1+1
Description
• Supported by WinLink 1000 radios with software upgrade to release 1.9.30, operating with IDU-C
(RW-72XX-2000) and new IDU-E (RW-71XX-2000).
• Supports various Ingress and Egress VLAN configuration options per IDU LAN port.
• When using VLAN ID for management traffic separation, be aware how you configure the system to
prevent conflicts.
• In the new IDU-E products the TDM clock recovery is done per TDM trunk separately.
• This is useful in scenarios where the RADWIN backhaul Link is shared by various networks (for
example, 2G and 3G, or several operators sharing sites), and each network has its own independent
clock.
• RADWIN’s Ethernet Ring Protection solution ensures Loops free.
• The Ethernet service restoration time depends on the number of hops in the ring. With 4 hops the
Ethernet service is restored in less than 50 ms.
• 1+1 Ethernet is a ring with two nodes.
Telnet Disable /
4. Enable
•
The user can disable the Telnet management interface via the RADWIN Manager
5. Max Frame Size
•
Max supported frame size by WinLink 1000 was increased from 1,800 Bytes to 2,047 Bytes with
software upgrade to release 1.9.30
•
New RADWIN Manager contextual online help (Press F1)
•
The user can schedule the date and time that the software upgrade for the required units in the network
will take effect.
•
The user has number of options to define if ODUs of a specific link or all ODUs in the in a list that
intend to be upgraded, will be reset or not after successful software upgrade.
RADWIN
6. Manager Online
help
Scheduled
7. Software
Upgrade
ODU reset
8. options after
software upgrade
6 Compatibility
Component
Name
1.
Link firmware
Description
With Ethernet only service release 1.9.30 is:
• Fully compatible with releases 1.750, 1.770, 1.790, 1.795, 1.8 and 1.9. "Software upgrade
recommended" is indicated.
• Fully compatible with release 1.630 (for WL1000-ACCESS products). "Software upgrade
recommended" is indicated.
• Partially compatible with releases 1.62X ("Software upgrade required" is indicated when using
HSS mixed mode).
Both sides of the link should be upgraded to release 1.9.30 in the following cases:
• For operation with TDM services with releases before 1.8
• For operation in bands 5.3 FCC, 5.4 ETSI and 5.4 IC with releases before 1.790.
• For operation in band 5.4 ETSI with releases 1.790 and 1.795, software upgrade is highly
recommended due to regulation change.
• For operation with equipment shipped with releases 1.5XX or earlier.
Page 9 of 13