User’s Manual 3. Select Noise tab at the top. Enter parameters as described in the following sections. Sweep Parameters Start value, Stop value Points per decade Number of points Define... Defines sweep range stop and start values Defines sweep range. The number of points of the sweep is defined per decade for a decade sweep. For a linear sweep you must enter the total number of points. Sets up desired sweep mode. See “Setting up a Swept Analysis” on page 193. Noise Parameters Output node This is compulsory. It is the name of the circuit node as it appears in the netlist. Usually the schematic's netlist generator chooses the node names but we recommend that when running a noise analysis that you assign a user defined name to your designated output node. To find out how to do this see “Finding and Specifying Net Names” on page 74. Reference node Optional. Output noise is referred to this node. This is assumed to be ground if it is omitted. Source name Optional. Voltage or current source to which input source is referred. Enter the part reference of either a voltage or current source. Monte Carlo and Multi-step Analysis See page 210 See Also .NOISE in Simulator Reference Manual. Plotting Results of Noise Analysis Refer to “Plotting Noise Analysis Results” on page 245 198