User’s Manual
Stop Plotting Data @ This is the time at which the process of creating plot data is
stopped i.e. when the PSP operation (see above) completes.
Number of Plot Points The total number of points to be generated. These will be evenly
spaced within the start and stop times.
Advanced...
Pressing the Advanced button opens the following dialog
Snapshot output
SIMPLIS has the ability to save its internal state in order to allow a run to be repeated
from a certain time point. This allows a run to be continued from where it previously
left off. (Similar to SIMetrix transient restart facility). The internal saved states are
known as snapshots.
SIMPLIS always saves a snapshot at the end of every run so if you start a new run of
the same circuit with a start time (Start Saving Data @) equal to the stop time of the
previous run, SIMPLIS will not need to rerun the start and instead will load the
snapshot state. SIMPLIS will do this automatically.
The entries in this dialog section allow you to specify the saving of snapshots at other
times as well as the end of a run. This might be useful if you wanted to restart a run at
some before the end of the previous run.
220
Enable snapshot output
Check this box to enable saving of snapshot
data. (Snapshots are always saved at the end of
a run)
Snapshot interval
This is the minimum duration between
snapshots.
Max snapshots
This is the maximum number of snapshots that
will be saved. This setting overrides Snapshot