Transcript
5.Operation ID 06 Group C Encoder related settings Contents Encoder Output Pulse Divide Resolution Selection Setting range Unit Standard value [PULOUTRES] 00 to 01 00:163840 P/R Control power reactivation after setting ■ This parameter is settable only when using serial encoder. ◆ Sets resolution of Encoder output pulse divide. ◆ Set at 163840P/R when Output pulse frequency exceeds the specification of the upper controller. ◆ Outputs divided pulse by setting resolution to ID04 Encoder output divide. 00 01 Selection 163840P/R 655360P/R Contents 163840 Pulse per 1 Motor Rotation 655360 Pulse per 1 Motor Rotation Resolver Signal Output(PS) Format Setting range [PSOFORM] 00 to 01 Control power reactivation after setting ■ Sets signal format of Encoder signal output (PS). 07 00 01 Selection MOT_Binary MOT_ASCII Contents Binary Code Output Decimal ASCII Code Output 5-79 Unit Standard value - 00:MOT_Binary